Wires and Cables
Overhead Insulated Cable

1/0 Neritina Aluminum Conductor Triplex Overhead Service Drop Cable
1/0 Neritina Triplex Aluminum Conductor Overhead Service Drop Cable is designed for dependable delivery of single-phase or split-phase electric power from pole-mounted transformers to the customer’s service entrance. This aerial cable consists of two phase conductors and one bare neutral messenger, constructed with high-conductivity aluminum and insulated with black cross-linked polyethylene (XLPE) for superior durability. Rated for 600 volts, the cable withstands conductor temperatures up to 75°C (for polyethylene insulation) or 90°C (for XLPE insulation). It meets all applicable ASTM and ICEA S-76-474 specifications, ensuring quality and compliance for utility, residential, and light commercial applications.
1/0 Purpura Aluminum Conductor Triplex Overhead Service Drop Cable
1/0 Purpura Triplex Aluminum Conductor Overhead Service Drop Cable is a durable and reliable aerial cable designed to deliver 600V power from utility lines to residential, commercial, or light industrial premises through a weatherhead service entrance. It consists of two insulated phase conductors and one bare neutral messenger, cabled together in a triplex configuration. The conductors are made of 1350-H19 aluminum, insulated with black cross-linked polyethylene (XLPE) for enhanced performance in extreme weather conditions, UV exposure, and mechanical stress.
1/0 Cenia Aluminum Conductor Triplex Overhead Service Drop Cable
1/0 Cenia Triplex Aluminum Conductor Overhead Service Drop Cable is designed for reliable power distribution from pole-mounted transformers to the customer's service entrance. This 600V-rated cable consists of two insulated phase conductors and one bare ACSR neutral messenger, arranged in a triplex configuration for ease of installation in overhead environments. Each aluminum conductor is 1350-H19 stranded and individually insulated with black cross-linked polyethylene (XLP), providing excellent resistance to UV, weather, and abrasion. The bare ACSR messenger supports the cable mechanically and also serves as the neutral conductor.
1/0 Ranella Aluminum Conductor Triplex Overhead Service Drop Cable
The 1/0 Gammarus Aluminum Conductor Triplex Overhead Service Drop Cable is engineered to deliver power from pole-mounted transformers directly to residential or light commercial service entrances. This triplex cable configuration consists of two phase conductors and one neutral messenger. Each aluminum conductor is insulated with black cross-linked polyethylene (XLP) for maximum protection against heat, moisture, and UV radiation. The bare AAAC neutral messenger supports the cable mechanically, allowing for safe and stable overhead suspension. Rated at 600 volts and compliant with ASTM and ICEA standards, this cable is designed for aerial use in overhead distribution systems where performance, strength, and reliability are required.
1/0 Echinus Aluminum Conductor Triplex Overhead Service Drop Cable
1/0 Echinus Triplex Aluminum Conductor Overhead Service Drop Cable is a high-performance electrical cable engineered for use in overhead power distribution systems. It features two insulated phase conductors and one bare AAAC (All-Aluminum Alloy Conductor) messenger, serving as the neutral and mechanical support. This triplex cable is rated for 600 volts and constructed to handle elevated conductor temperatures of up to 90°C with XLPE insulation. Suitable for both residential and commercial aerial service connections, this cable delivers reliable conductivity, mechanical strength, and long-term weather resistance.
1/0 Janthina Aluminum Conductor Triplex Overhead Service Drop Cable
The 1/0 Gammarus Aluminum Conductor Triplex Overhead Service Drop Cable is engineered to deliver power from pole-mounted transformers directly to residential or light commercial service entrances. This triplex cable configuration consists of two phase conductors and one neutral messenger. Each aluminum conductor is insulated with black cross-linked polyethylene (XLP) for maximum protection against heat, moisture, and UV radiation. The bare AAAC neutral messenger supports the cable mechanically, allowing for safe and stable overhead suspension. Rated at 600 volts and compliant with ASTM and ICEA standards, this cable is designed for aerial use in overhead distribution systems where performance, strength, and reliability are required.
1/0 Sandcrab Aluminum Conductor Triplex Overhead Service Drop Cable
1/0 Sandcrab Aluminum Conductor Overhead Service Drop Cable has three conductors, with one of them being for neutral path, and two electrodes. Used to supply power, usually from a pole-mounted transformer, to the user's service head where connection to the service entrance cable is made. To be used at voltages of 600 volts phase-to-phase or less and at conductor temperatures not to exceed 75°C for polyethylene insulated conductors or 90°C for cross-linked polyethylene (XLPE) insulated conductors. A bare messenger wire of this electrical cable is bonded closely on the two insulated aluminum conductors, which are individually insulated with black cross-linked polyethylene for protection.
2/0 Cavolinia Aluminum Conductor Triplex Overhead Service Drop Cable
2/0 Cavolinia Aluminum Conductor Triplex Overhead Service Drop Cable is a durable and cost-effective solution for transmitting power from utility poles to buildings or residences. Designed for 600-volt aerial applications, this triplex cable includes two insulated phase conductors and one bare neutral messenger made of ACSR for added strength and support. Each phase conductor is insulated with black cross-linked polyethylene (XLPE), offering excellent resistance to weathering, UV exposure, and mechanical stress. The messenger conductor also serves as the neutral and supports the cable in overhead configurations.
2/0 Clio Aluminum Conductor Triplex Overhead Service Drop Cable
The 2/0 Clio Triplex Aluminum Overhead Service Drop Cable is engineered for dependable electrical power distribution from utility lines to residential, commercial, and industrial buildings. This cable includes two phase conductors and one neutral messenger, twisted together to form a durable triplex configuration. Each phase conductor is insulated with black cross-linked polyethylene (XLPE), providing excellent mechanical strength, UV resistance, and long-term weather protection. The bare messenger conductor, typically made of ACSR (Aluminum Conductor Steel Reinforced), serves both as mechanical support and electrical neutral.Why Choose Us
As a trusted partner in energy savings and the development of green energy solutions, NPC
Electric has played a pioneering role in the development of national smart grids across
multiple regions.

Project Experience
With years of experience in power transmission and distribution, NPC Electric has become
a trusted name in the manufacturing of cables and transformers. We’ve successfully
served international EPC companies such as Elecnor, Cobra, and Equans in Latin America,
Africa, and Southeast Asia.We have provided the 132kV Power Transformer,Pad Mounted
Transformer and Earth Transformer.

Technical Support
NPC Electric’s skilled engineers offer full-cycle support—from design consultation and
technical drawings to on-site guidance and after-sales service—ensuring peace of mind at
every stage of the project.
We have a technical team of over 60 members and more than 100 after-sales engineers,
ready to assist customers with installation and on-site support.
Till now, we have provided professional engineering services in countries such as
Mongolia, Honduras, Peru, and Rwanda. Our services include winding resistance testing,
oil testing, and installation support.

Quality Control
NPC Electric uses high-quality raw materials and advanced production processes,
supported by strict quality control systems. Our products meet or exceed international
standards such as IEC, UL, and ISO, ensuring safety, reliability, and long service life.
All our cables are subject to third-party laboratory testing—such as by SGS, DNV, or
witnessed directly by customers—to ensure compliance and performance.

Efficient Logistics & Timely Delivery
With over 4,200 sqm of warehouse space and a strategic in China, we guarantee timely
delivery and flexible logistics to meet tight project schedules globally.We have the
professional team to assitance the customer to ship the production, we can do
EXW,CIF,FOB,FCA,CIP or any customer request terms.
Technical Advantages
● 30+ years of manufacturing experience
● ISO and UL certified production
● Customized cable and transformer solutions
FAQ From Customers
-
What are the advantages of power cables and overhead lines?(1) Reliable operation, because it is installed in a hidden place such as underground, it is less damaged by external forces, has less chance of failure, and the power supply is safe, and it will not cause harm to people; (2) The maintenance workload is small and frequent inspections are not required; (3) No need to erect towers; (4) Help improve power factor.
-
Which aspects should be considered when choosing the cross section of a power cable?(1) The long-term allowable working current of the cable; (2) Thermal stability once short circuited; (3) The voltage drop on the line cannot exceed the allowable working range.
-
What are the measures for cable fire prevention?(1) Use flame-retardant cables; (2) Use fireproof cable tray; (3) Use fireproof paint; (4) Fire partition walls and fire baffles are installed at cable tunnels, mezzanine exits, etc.; (5) Overhead cables should avoid oil pipelines and explosion-proof doors, otherwise local pipes or heat insulation and fire prevention measures should be taken.
-
What should be paid attention to during the transportation and handling of cables?(1) During transportation, loading and unloading, cables and cable reels should not be damaged. It is strictly forbidden to push the cable reels directly from the vehicle. Generally, cables should not be transported and stored flat. (2) Before transporting or rolling the cable reel, ensure that the cable reel is firm, the cable is wound tightly, the oil pipe between the oil-filled cable and the pressure oil tank should be fixed without damage, the pressure oil tank should be firm, and the pressure indication should meet the requirements.
-
What inspections should be carried out for the acceptance of cable lines?(1) The cable specifications should meet the regulations, the arrangement should be neat, no damage, and the signs should be complete, correct and clear; (2) The fixed bending radius of the cable, the related distance and the wiring of the metal sheath of the single-core power cable should meet the requirements; (3) The cable terminal and the middle head should not leak oil, and the installation should be firm. The oil pressure of the oil-filled cable and the meter setting should meet the requirements; (4) Good grounding; (5) The color of the cable terminal is correct, and the metal parts such as the bracket are completely painted; (6) There should be no debris in the cable trench, tunnel, and bridge, and the cover should be complete.
Welcome your inquiry
Honesty, Integrity, Frugality, Activeness and Passion