Wires and Cables
Overhead Insulated Cable
1/0 Neritina Aluminum Conductor Triplex Overhead Service Drop Cable
1/0 Neritina Aluminum Conductor Triplex Overhead Service Drop Cable is designed for reliable secondary overhead power distribution from utility poles to residential and light commercial service entrances. The triplex structure consists of two insulated aluminum phase conductors helically wrapped around a bare aluminum neutral messenger, which provides both electrical grounding and mechanical support. The 1/0 Neritina conductor size offers enhanced current-carrying capacity, strong tensile performance, and controlled sag characteristics, making it suitable for longer spans and higher service loads. Aluminum conductors reduce overall cable weight while delivering excellent corrosion resistance and ease of installation in outdoor environments. Manufactured in compliance with ASTM and utility specifications, the 1/0 Neritina Aluminum Conductor Triplex Overhead Service Drop Cable ensures stable electrical performance, long service life, and dependable mechanical integrity. It is widely adopted by utilities and contractors seeking a cost-efficient and durable overhead service drop solution.
1/0 Purpura Aluminum Conductor Triplex Overhead Service Drop Cable
The 1/0 Purpura Aluminum Conductor Triplex Overhead Service Drop Cable is engineered for dependable secondary overhead power distribution from utility poles to residential and light commercial service entrances. The triplex configuration consists of two insulated aluminum phase conductors helically stranded around a bare aluminum neutral messenger, which provides both mechanical support and grounding functionality. With a 1/0 Purpura conductor size, this cable delivers enhanced current-carrying capacity, improved tensile strength, and controlled sag performance, making it suitable for longer spans and higher service loads. Aluminum conductors offer excellent corrosion resistance, reduced overall weight, and ease of handling during installation. Manufactured to meet ASTM and utility specifications, the 1/0 Purpura Aluminum Conductor Triplex Overhead Service Drop Cable ensures stable electrical performance, long service life, and consistent mechanical reliability in outdoor environments.
1/0 Cenia Aluminum Conductor Triplex Overhead Service Drop Cable
1/0 Cenia Aluminum Conductor Triplex Overhead Service Drop Cable is designed for dependable secondary overhead power distribution from utility lines to residential and light commercial service entrances. Its triplex construction features two insulated aluminum phase conductors helically wrapped around a bare aluminum neutral messenger, which provides both mechanical support and grounding continuity. With a 1/0 Cenia conductor size, this cable delivers increased current-carrying capacity, strong tensile strength, and controlled sag performance, making it suitable for longer spans and higher service demands. Aluminum conductors reduce overall cable weight while offering excellent corrosion resistance and long-term durability in outdoor environments. Manufactured in accordance with ASTM and utility standards, the 1/0 Cenia Aluminum Conductor Triplex Overhead Service Drop Cable ensures stable electrical transmission, reliable mechanical performance, and consistent quality throughout its service life.
1/0 Ranella Aluminum Conductor Triplex Overhead Service Drop Cable
1/0 Ranella Triplex Service Drop Cable is a reliable overhead cable for secondary power distribution to residential service entrances. Featuring two 1/0 AWG aluminum phase conductors and one neutral messenger (7-strand) insulated with XLPE or PE and assembled in triplex configuration, it provides excellent mechanical strength and weather resistance. Compliant with ASTM B-230, B-231, ICEA S-76-474, and ANSI/ICEA standards, this cable supports 600V applications with high UV, moisture, and abrasion protection. The self-supporting messenger reduces sag and simplifies installation over medium spans. The 1/0 Ranella Triplex Service Drop Cable ensures low power losses, high current capacity, and long service life in harsh outdoor conditions. Lightweight and flexible, it is widely used for two-phase service drops with neutral in urban, suburban, and rural areas requiring safe, cost-effective aerial connections from utility poles to homes.
1/0 Echinus Aluminum Conductor Triplex Overhead Service Drop Cable
NPC Electric 1/0 Echinus Triplex Service Drop Cable provides reliable overhead secondary distribution for residential applications. Consisting of two 1/0 AWG aluminum phase conductors and one neutral messenger (7-strand) insulated with cross-linked polyethylene (XLPE) and twisted in triplex form, it meets ASTM, ICEA, and international standards. The robust insulation resists sunlight, moisture, and mechanical damage for decades of outdoor service. Lightweight design simplifies installation with low sag and easy handling. The 1/0 Echinus Triplex Service Drop Cable ensures minimal losses, high current capacity, and excellent weather performance up to 600V. Self-supporting messenger reduces pole loading. Flame-retardant options enhance safety. Commonly chosen for two-phase power delivery with neutral in subdivisions, rural homes, and temporary connections requiring safe, economical aerial bundled solutions with proven durability.
1/0 Janthina Aluminum Conductor Triplex Overhead Service Drop Cable
The 1/0 Janthina Triplex Service Drop Cable is a reliable overhead cable for secondary power distribution to residential service entrances. Featuring two 1/0 AWG aluminum phase conductors and one neutral messenger (7-strand) insulated with XLPE or PE and assembled in triplex configuration, it provides excellent mechanical strength and weather resistance. Compliant with ASTM B-230, B-231, ICEA S-76-474, and ANSI/ICEA standards, this cable supports 600V applications with high UV, moisture, and abrasion protection. The self-supporting messenger reduces sag and simplifies installation over medium spans. The 1/0 Janthina Triplex Service Drop Cable ensures low power losses, high current capacity, and long service life in harsh outdoor conditions. Lightweight and flexible, it is widely used for two-phase service drops with neutral in urban, suburban, and rural areas requiring safe, cost-effective aerial connections from utility poles to homes.
1/0 Sandcrab Aluminum Conductor Triplex Overhead Service Drop Cable
NPC Electric 1/0 Sandcrab Triplex Service Drop Cable provides reliable overhead secondary distribution for residential applications. Consisting of two 1/0 AWG aluminum phase conductors and one neutral messenger (7-strand) insulated with cross-linked polyethylene (XLPE) and twisted in triplex form, it meets ASTM, ICEA, and international standards. The robust insulation resists sunlight, moisture, and mechanical damage for decades of outdoor service. Lightweight design simplifies installation with low sag and easy handling. The 1/0 Sandcrab Triplex Service Drop Cable ensures minimal losses, high current capacity, and excellent weather performance up to 600V. Self-supporting messenger reduces pole loading. Flame-retardant options enhance safety. Commonly chosen for two-phase power delivery with neutral in subdivisions, rural homes, and temporary connections requiring safe, economical aerial bundled solutions with proven durability.
2/0 Cavolinia Aluminum Conductor Triplex Overhead Service Drop Cable
The 2/0 Cavolinia Triplex Service Drop Cable is a reliable overhead cable for secondary power distribution to residential service entrances. Featuring two 2/0 AWG aluminum phase conductors and one neutral messenger (7-strand) insulated with XLPE or PE and assembled in triplex configuration, it provides excellent mechanical strength and weather resistance. Compliant with ASTM B-230, B-231, ICEA S-76-474, and ANSI/ICEA standards, this cable supports 600V applications with high UV, moisture, and abrasion protection. The self-supporting messenger reduces sag and simplifies installation over medium spans. The 2/0 Cavolinia Triplex Service Drop Cable ensures low power losses, high current capacity, and long service life in harsh outdoor conditions. Lightweight and flexible, it is widely used for two-phase service drops with neutral in urban, suburban, and rural areas requiring safe, cost-effective aerial connections from utility poles to homes.
2/0 Clio Aluminum Conductor Triplex Overhead Service Drop Cable
The 2/0 Clio Triplex Service Drop Cable is engineered for dependable overhead secondary power distribution to residential and small commercial service entrances. It features two 2/0 AWG aluminum phase conductors and one neutral messenger (7-strand aluminum or ACSR) with cross-linked polyethylene (XLPE) insulation in triplex configuration. Compliant with ASTM B-230, B-231, ICEA S-76-474, and ANSI/ICEA standards, this cable supports 600V applications with excellent UV, moisture, and abrasion resistance. The self-supporting messenger minimizes sag and enables easy installation across medium spans. The 2/0 Clio Triplex Service Drop Cable delivers low voltage drop, high current-carrying capacity, and outstanding durability in harsh weather conditions. Its lightweight and flexible design makes it the preferred choice for safe, cost-effective aerial connections from utility poles to customer service entrances in urban, suburban, and rural electrification projects worldwide.In-Depth Analysis
Comparative Analysis of Efficiency and Loss
Compared to the industry average, NPC Overhead Insulated Cable exhibit lower losses and higher efficiency across the entire load range.
Load Efficiency Comparison(%)
No-load Loss Comparison(W)
High Conductivity Design
High-purity oxygen-free copper or high-quality aluminum conductors are used with smooth surface and low resistance to ensure efficient power transmission and reduce energy loss.
Insulation Protection System
Use flame-retardant, wear-resistant and corrosion-resistant polymer insulation materials to meet the safe operation requirements in different environments.
Weather-Resistant & Durable Technology
The outer sheath is made of UV-resistant, heat-resistant, and oil-resistant materials, making it suitable for high and low temperatures, humidity, and long-term outdoor use.
Safe Flame Retardant System
The multi-layered flame-retardant structure effectively slows the spread of flames and releases low-smoke, halogen-free gases during combustion, reducing secondary hazards.
Easy Installation & Maintenance
The flexible core and flex-resistant outer sheath provide a small bend radius and high installation efficiency. Color coding and length markings reduce installation and maintenance costs.
Intelligent Monitoring
An optional remote monitoring system is available to monitor operating status, temperature, load and other parameters in real time, and supports fault warning and remote diagnosis.
Environmental Adaptability Analysis
NPC Overhead Insulated Cable have been rigorously tested and can operate stably under various harsh environmental conditions.
Temperature Range
-40℃ ~ +55℃
Can work normally in extreme high and low temperature environments
Humidity Adaptation
0 ~ 100% RH
Including condensation environment, no frost requirement
Weather Resistance Grade
UV/IEC 60811-501
The outer sheath has excellent UV resistance and aging resistance
Chemical Corrosion Resistance
Oil / Acid / Alkali
Resistant to oil, acid, alkali and some chemical corrosion environments
Why Choose Us
Overhead Insulated Cable Manufacturer
Overhead Insulated Cable Benefits
Overhead Insulated Cable Installation
Testing and Certification
Product Show
Testing and Certification
Bare Cable Test Report
SGS Inspection Report
Certificate of Acceptance
ISO Quality Certificate
ISO Environmental Certificate
ISO Occupational Certificate
UL Laboratory Certificate
UL Product Certificate
Project Cases
Peru Solar PV Project
CompletedNPC Electric Delivers Medium-Voltage Cables for Peru Solar PV Project
Country:Peru
Model:HEPRZ1(AS) 1x630 mm² 19/33kV x 6km
Chile El Project
CompletedReliable 19/33kV MV cables ensuring safe, stable, and efficient power transmission for critical projects.
Country:Chile
Model:19/33kV MV Power Cables x 5km
Dominican Edenorte Project
CompletedProvide outdoor power solutions for urban main road reconstruction projects to adapt to complex environments.
Country:Dominican
Model:NPC AAAC Cable & Triplex Cable x 10km
Technical Advantages
FAQ From Customers
-
What is the structure of an overhead insulated cable?
Overhead insulated cables typically consist of a conductor, insulation layer, and an optional outer sheath. The conductor is usually made from aluminum or copper, providing excellent electrical conductivity. The insulation layer, made from materials like cross-linked polyethylene (XLPE) or PVC, protects the conductor and prevents accidental contact with live wires. An optional outer sheath is added for additional mechanical protection and durability, particularly in harsh environmental conditions. -
What materials are used for the insulation of overhead insulated cables?
The insulation of overhead insulated cables is typically made from cross-linked polyethylene (XLPE), which offers superior thermal stability, electrical insulation properties, and resistance to environmental factors. Alternatively, PVC (polyvinyl chloride) can be used for lower voltage applications. These materials help prevent electrical hazards by ensuring that the conductor remains safely insulated, especially in outdoor and exposed environments such as overhead power lines. -
How are overhead insulated cables manufactured?
The manufacturing process of overhead insulated cables begins with the conductor preparation, which involves drawing aluminum or copper to the desired size. The insulation layer is then applied using extrusion technology, ensuring uniform thickness and durability. For high voltage cables, the insulation is cross-linked to improve performance at elevated temperatures and resist electrical stress. The outer sheath is then added, providing protection against physical damage and environmental conditions. The entire process follows stringent quality control and testing procedures to ensure reliability and compliance with international standards such as IEC and ANSI. -
What makes overhead insulated cables suitable for high voltage applications?
Overhead insulated cables are suitable for high voltage applications due to their specialized insulation materials such as cross-linked polyethylene (XLPE), which provides excellent electrical strength and thermal stability. These materials prevent the risk of electrical leakage and offer protection against high voltage surges. The cables' mechanical strength and weather-resistant outer sheath ensure long-term durability and performance, even in extreme environments. Additionally, the insulated layers prevent external damage from wind, moisture, and physical contact, making them ideal for high-voltage power transmission. -
How do overhead insulated cables protect against environmental factors?
Overhead insulated cables are designed to withstand environmental challenges such as moisture, extreme temperatures, UV radiation, and mechanical stress. The insulation material, typically XLPE or PVC, offers excellent resistance to corrosion and weathering, ensuring long-lasting performance even in harsh climates. The outer sheath further protects the cable from abrasion, chemical exposure, and physical damage, ensuring that the cables maintain their integrity and electrical safety during their service life.