Wires and Cables
Overhead Insulated Cable
1/0 Neritina Aluminum Conductor Triplex Overhead Service Drop Cable
1/0 Neritina Triplex Aluminum Conductor Overhead Service Drop Cable is designed for dependable delivery of single-phase or split-phase electric power from pole-mounted transformers to the customer’s service entrance. This aerial cable consists of two phase conductors and one bare neutral messenger, constructed with high-conductivity aluminum and insulated with black cross-linked polyethylene (XLPE) for superior durability. Rated for 600 volts, the cable withstands conductor temperatures up to 75°C (for polyethylene insulation) or 90°C (for XLPE insulation). It meets all applicable ASTM and ICEA S-76-474 specifications, ensuring quality and compliance for utility, residential, and light commercial applications.
1/0 Purpura Aluminum Conductor Triplex Overhead Service Drop Cable
1/0 Purpura Triplex Aluminum Conductor Overhead Service Drop Cable is a durable and reliable aerial cable designed to deliver 600V power from utility lines to residential, commercial, or light industrial premises through a weatherhead service entrance. It consists of two insulated phase conductors and one bare neutral messenger, cabled together in a triplex configuration. The conductors are made of 1350-H19 aluminum, insulated with black cross-linked polyethylene (XLPE) for enhanced performance in extreme weather conditions, UV exposure, and mechanical stress.
1/0 Cenia Aluminum Conductor Triplex Overhead Service Drop Cable
1/0 Cenia Triplex Aluminum Conductor Overhead Service Drop Cable is designed for reliable power distribution from pole-mounted transformers to the customer's service entrance. This 600V-rated cable consists of two insulated phase conductors and one bare ACSR neutral messenger, arranged in a triplex configuration for ease of installation in overhead environments. Each aluminum conductor is 1350-H19 stranded and individually insulated with black cross-linked polyethylene (XLP), providing excellent resistance to UV, weather, and abrasion. The bare ACSR messenger supports the cable mechanically and also serves as the neutral conductor.
1/0 Ranella Aluminum Conductor Triplex Overhead Service Drop Cable
The 1/0 Gammarus Aluminum Conductor Triplex Overhead Service Drop Cable is engineered to deliver power from pole-mounted transformers directly to residential or light commercial service entrances. This triplex cable configuration consists of two phase conductors and one neutral messenger. Each aluminum conductor is insulated with black cross-linked polyethylene (XLP) for maximum protection against heat, moisture, and UV radiation. The bare AAAC neutral messenger supports the cable mechanically, allowing for safe and stable overhead suspension. Rated at 600 volts and compliant with ASTM and ICEA standards, this cable is designed for aerial use in overhead distribution systems where performance, strength, and reliability are required.
1/0 Echinus Aluminum Conductor Triplex Overhead Service Drop Cable
1/0 Echinus Triplex Aluminum Conductor Overhead Service Drop Cable is a high-performance electrical cable engineered for use in overhead power distribution systems. It features two insulated phase conductors and one bare AAAC (All-Aluminum Alloy Conductor) messenger, serving as the neutral and mechanical support. This triplex cable is rated for 600 volts and constructed to handle elevated conductor temperatures of up to 90°C with XLPE insulation. Suitable for both residential and commercial aerial service connections, this cable delivers reliable conductivity, mechanical strength, and long-term weather resistance.
1/0 Janthina Aluminum Conductor Triplex Overhead Service Drop Cable
The 1/0 Gammarus Aluminum Conductor Triplex Overhead Service Drop Cable is engineered to deliver power from pole-mounted transformers directly to residential or light commercial service entrances. This triplex cable configuration consists of two phase conductors and one neutral messenger. Each aluminum conductor is insulated with black cross-linked polyethylene (XLP) for maximum protection against heat, moisture, and UV radiation. The bare AAAC neutral messenger supports the cable mechanically, allowing for safe and stable overhead suspension. Rated at 600 volts and compliant with ASTM and ICEA standards, this cable is designed for aerial use in overhead distribution systems where performance, strength, and reliability are required.
1/0 Sandcrab Aluminum Conductor Triplex Overhead Service Drop Cable
1/0 Sandcrab Aluminum Conductor Overhead Service Drop Cable has three conductors, with one of them being for neutral path, and two electrodes. Used to supply power, usually from a pole-mounted transformer, to the user's service head where connection to the service entrance cable is made. To be used at voltages of 600 volts phase-to-phase or less and at conductor temperatures not to exceed 75°C for polyethylene insulated conductors or 90°C for cross-linked polyethylene (XLPE) insulated conductors. A bare messenger wire of this electrical cable is bonded closely on the two insulated aluminum conductors, which are individually insulated with black cross-linked polyethylene for protection.
2/0 Cavolinia Aluminum Conductor Triplex Overhead Service Drop Cable
2/0 Cavolinia Aluminum Conductor Triplex Overhead Service Drop Cable is a durable and cost-effective solution for transmitting power from utility poles to buildings or residences. Designed for 600-volt aerial applications, this triplex cable includes two insulated phase conductors and one bare neutral messenger made of ACSR for added strength and support. Each phase conductor is insulated with black cross-linked polyethylene (XLPE), offering excellent resistance to weathering, UV exposure, and mechanical stress. The messenger conductor also serves as the neutral and supports the cable in overhead configurations.
2/0 Clio Aluminum Conductor Triplex Overhead Service Drop Cable
The 2/0 Clio Triplex Aluminum Overhead Service Drop Cable is engineered for dependable electrical power distribution from utility lines to residential, commercial, and industrial buildings. This cable includes two phase conductors and one neutral messenger, twisted together to form a durable triplex configuration. Each phase conductor is insulated with black cross-linked polyethylene (XLPE), providing excellent mechanical strength, UV resistance, and long-term weather protection. The bare messenger conductor, typically made of ACSR (Aluminum Conductor Steel Reinforced), serves both as mechanical support and electrical neutral.In-Depth Analysis
Comparative Analysis of Efficiency and Loss
Compared to the industry average, NPC Overhead Insulated Cable exhibit lower losses and higher efficiency across the entire load range.
Load Efficiency Comparison(%)
No-load Loss Comparison(W)
High Conductivity Design
High-purity oxygen-free copper or high-quality aluminum conductors are used with smooth surface and low resistance to ensure efficient power transmission and reduce energy loss.
Insulation Protection System
Use flame-retardant, wear-resistant and corrosion-resistant polymer insulation materials to meet the safe operation requirements in different environments.
Weather-Resistant & Durable Technology
The outer sheath is made of UV-resistant, heat-resistant, and oil-resistant materials, making it suitable for high and low temperatures, humidity, and long-term outdoor use.
Safe Flame Retardant System
The multi-layered flame-retardant structure effectively slows the spread of flames and releases low-smoke, halogen-free gases during combustion, reducing secondary hazards.
Easy Installation & Maintenance
The flexible core and flex-resistant outer sheath provide a small bend radius and high installation efficiency. Color coding and length markings reduce installation and maintenance costs.
Intelligent Monitoring
An optional remote monitoring system is available to monitor operating status, temperature, load and other parameters in real time, and supports fault warning and remote diagnosis.
Environmental Adaptability Analysis
NPC Overhead Insulated Cable have been rigorously tested and can operate stably under various harsh environmental conditions.
Temperature Range
-40℃ ~ +55℃
Can work normally in extreme high and low temperature environments
Humidity Adaptation
0 ~ 100% RH
Including condensation environment, no frost requirement
Weather Resistance Grade
UV/IEC 60811-501
The outer sheath has excellent UV resistance and aging resistance
Chemical Corrosion Resistance
Oil / Acid / Alkali
Resistant to oil, acid, alkali and some chemical corrosion environments
Why Choose Us
Overhead Insulated Cable Manufacturer
Overhead Insulated Cable Benefits
Overhead Insulated Cable Installation
Testing and Certification
Product Show
Testing and Certification
Bare Cable Test Report
SGS Inspection Report
Certificate of Acceptance
ISO Quality Certificate
ISO Environmental Certificate
ISO Occupational Certificate
UL Laboratory Certificate
UL Product Certificate
Project Cases
Peru Solar PV Project
CompletedNPC Electric Delivers Medium-Voltage Cables for Peru Solar PV Project
Country:Peru
Model:HEPRZ1(AS) 1x630 mm² 19/33kV x 6km
Chile El Project
CompletedReliable 19/33kV MV cables ensuring safe, stable, and efficient power transmission for critical projects.
Country:Chile
Model:19/33kV MV Power Cables x 5km
Dominican Edenorte Project
CompletedProvide outdoor power solutions for urban main road reconstruction projects to adapt to complex environments.
Country:Dominican
Model:NPC AAAC Cable & Triplex Cable x 10km
Technical Advantages
FAQ From Customers
-
What is the structure of an overhead insulated cable?
Overhead insulated cables typically consist of a conductor, insulation layer, and an optional outer sheath. The conductor is usually made from aluminum or copper, providing excellent electrical conductivity. The insulation layer, made from materials like cross-linked polyethylene (XLPE) or PVC, protects the conductor and prevents accidental contact with live wires. An optional outer sheath is added for additional mechanical protection and durability, particularly in harsh environmental conditions. -
What materials are used for the insulation of overhead insulated cables?
The insulation of overhead insulated cables is typically made from cross-linked polyethylene (XLPE), which offers superior thermal stability, electrical insulation properties, and resistance to environmental factors. Alternatively, PVC (polyvinyl chloride) can be used for lower voltage applications. These materials help prevent electrical hazards by ensuring that the conductor remains safely insulated, especially in outdoor and exposed environments such as overhead power lines. -
How are overhead insulated cables manufactured?
The manufacturing process of overhead insulated cables begins with the conductor preparation, which involves drawing aluminum or copper to the desired size. The insulation layer is then applied using extrusion technology, ensuring uniform thickness and durability. For high voltage cables, the insulation is cross-linked to improve performance at elevated temperatures and resist electrical stress. The outer sheath is then added, providing protection against physical damage and environmental conditions. The entire process follows stringent quality control and testing procedures to ensure reliability and compliance with international standards such as IEC and ANSI. -
What makes overhead insulated cables suitable for high voltage applications?
Overhead insulated cables are suitable for high voltage applications due to their specialized insulation materials such as cross-linked polyethylene (XLPE), which provides excellent electrical strength and thermal stability. These materials prevent the risk of electrical leakage and offer protection against high voltage surges. The cables' mechanical strength and weather-resistant outer sheath ensure long-term durability and performance, even in extreme environments. Additionally, the insulated layers prevent external damage from wind, moisture, and physical contact, making them ideal for high-voltage power transmission. -
How do overhead insulated cables protect against environmental factors?
Overhead insulated cables are designed to withstand environmental challenges such as moisture, extreme temperatures, UV radiation, and mechanical stress. The insulation material, typically XLPE or PVC, offers excellent resistance to corrosion and weathering, ensuring long-lasting performance even in harsh climates. The outer sheath further protects the cable from abrasion, chemical exposure, and physical damage, ensuring that the cables maintain their integrity and electrical safety during their service life.