2 Cockle Aluminum Conductor Triplex Overhead Service Drop Cable
The 2-2-4 Cockle Aluminum Conductor Triplex Overhead Service Drop Cable is engineered for efficient overhead power supply from utility poles to residential or commercial weatherheads. It consists of two concentric-lay-stranded 1350-H19 aluminum phase conductors (#2 AWG, 7-strand), black cross-linked polyethylene (XLPE) insulation for superior weather, UV, and thermal resistance, and a bare ACSR neutral messenger (#4 AWG, 6/1) providing mechanical strength and conductivity. Rated for 600 volts phase-to-phase at conductor temperatures up to 90°C (XLPE) or 75°C (Poly), it offers an allowable ampacity of approximately 150 amps (XLP). Compliant with ASTM B-230, B-231, B-232, B-399, and ICEA S-76-474 standards, this lightweight, flexible cable facilitates straightforward installation and ensures long-term reliability in harsh outdoor environments, including exposure to wind, ice, moisture, and temperature variations.
2 Solaster Aluminum Conductor Triplex Overhead Service Drop Cable
The 2 Solaster Aluminum Conductor Triplex Overhead Service Drop Cable is designed for reliable overhead electrical service connections from utility distribution lines to residential and light commercial buildings. The cable consists of two insulated aluminum phase conductors twisted around a bare aluminum neutral messenger, providing stable electrical transmission and strong mechanical support. Manufactured using high-purity aluminum and weather-resistant insulation compounds, the 2 Solaster Aluminum Conductor Triplex Overhead Service Drop Cable offers low electrical resistance, excellent corrosion resistance, and long-term durability in outdoor environments. Its lightweight construction allows for efficient handling and installation while maintaining the tensile strength required for aerial service applications. The cable is engineered to perform consistently under UV exposure, wind loading, and temperature fluctuations. Comprehensive quality control procedures and systematic testing are applied throughout production to ensure compliance with industry and utility standards.
3/0 Aega Aluminum Conductor Triplex Overhead Service Drop Cable
The 3/0 Aega Aluminum Conductor Triplex Overhead Service Drop Cable is designed to deliver safe and efficient overhead power distribution for utility networks. It features two insulated aluminum phase conductors helically wrapped around a bare aluminum neutral messenger, providing strong mechanical support and stable electrical performance. Manufactured using premium aluminum materials and high-performance insulation compounds, the 3/0 Aega Aluminum Conductor Triplex Overhead Service Drop Cable offers excellent resistance to corrosion, UV radiation, and environmental stress. Its optimized construction supports easy handling and installation while meeting utility and industry standards. The cable performs reliably under mechanical load, temperature variation, and long-term outdoor exposure. Strict quality management systems and detailed testing procedures are implemented throughout production to ensure consistent performance and dependable service life.
3/0 Fulgar Aluminum Conductor Triplex Overhead Service Drop Cable
3/0 Fulgar Aluminum Conductor Triplex Overhead Service Drop Cable is engineered for high-capacity overhead electrical service connections in utility distribution systems. The cable consists of two insulated aluminum phase conductors twisted around a bare aluminum neutral messenger, ensuring stable electrical transmission and strong mechanical support. Manufactured using high-purity aluminum and weather-resistant insulation compounds, the 3/0 Fulgar Aluminum Conductor Triplex Overhead Service Drop Cable delivers low electrical resistance, excellent corrosion resistance, and reliable long-term performance in outdoor environments. Its optimized conductor design allows efficient installation while maintaining the tensile strength required for aerial service applications. The cable is designed to withstand UV exposure, wind loading, and temperature fluctuations. Comprehensive quality control procedures and systematic testing are applied throughout the manufacturing process to ensure compliance with industry and utility standards and dependable field operation.
3/0 Cherrystone Aluminum Conductor Triplex Overhead Service Cable
The 3/0 Cherrystone Aluminum Conductor Triplex Overhead Service Cable is engineered to deliver safe, efficient, and durable overhead power distribution for utility networks. It features two insulated aluminum phase conductors helically wrapped around a bare aluminum neutral messenger, providing strong mechanical support and stable electrical performance. Manufactured using premium aluminum materials and high-performance insulation compounds, the 3/0 Cherrystone Aluminum Conductor Triplex Overhead Service Cable offers excellent resistance to corrosion, UV radiation, and environmental stress. Its optimized structure supports easy handling and installation while meeting utility and industry standards. The cable performs reliably under mechanical load, temperature variation, and prolonged outdoor exposure. Strict quality management systems and detailed testing procedures are implemented throughout production to ensure consistent performance and dependable service life.
3/0 Flustra Aluminum Conductor Triplex Overhead Service Drop Cable
The 3/0 Flustra Triplex Aluminum Overhead Service Drop Cable is a highly durable, weather-resistant cable designed for power distribution from utility poles to residential or light commercial buildings. This triplex cable includes two phase conductors and one bare neutral messenger, typically made of AAAC (All-Aluminum Alloy Conductor), providing both support and a current return path. With a voltage rating of 600V phase-to-phase and XLPE (Cross-Linked Polyethylene) insulation, this cable is built for high performance and reliability in aerial applications. The cable structure consists of two insulated aluminum phase conductors helically wrapped around a bare aluminum neutral messenger, providing stable electrical transmission and strong mechanical support. Manufactured using high-purity aluminum and weather-resistant insulation compounds, the 3/0 Flustra Aluminum Conductor Triplex Overhead Service Drop Cable delivers low electrical resistance, excellent corrosion resistance, and long-term durability in outdoor environments. Its optimized conductor design supports efficient installation while maintaining the tensile strength required for aerial service applications.
3/0 Melita Aluminum Conductor Triplex Overhead Service Drop Cable
The 3/0-3/0-3/0 Melita Aluminum Conductor Triplex Overhead Service Drop Cable is designed for high-performance overhead power distribution from utility poles to residential, commercial, or light industrial weatherheads. It features concentric-lay-stranded 1350-H19 aluminum conductors (#3/0 AWG, 19-strand), black cross-linked polyethylene (XLPE) insulation for exceptional weather, UV, and thermal resistance, and a bare neutral messenger (#3/0 AWG, typically ACSR or AAC). Rated for 600 volts phase-to-phase at conductor temperatures up to 90°C (XLPE) or 75°C (Poly), it supports an allowable ampacity of approximately 275 amps (XLP). Compliant with ASTM B-230, B-231, B-232, B-399, and ICEA S-76-474 standards, this robust yet lightweight cable ensures easy installation, excellent conductivity, and long-term durability in challenging outdoor conditions like wind, ice, moisture, and temperature extremes.
3/0 Mursia Aluminum Conductor Triplex Overhead Service Drop Cable
The 3/0 Mursia Triplex Aluminum Overhead Service Drop Cable is a premium-grade aerial electrical cable engineered for utility-to-premises power distribution. Designed with two insulated phase conductors and one bare ACSR (Aluminum Conductor Steel Reinforced) neutral messenger, the Mursia cable ensures strength, conductivity, and stability during aerial installation. Constructed with concentric or compressed 1350-H19 aluminum phase conductors (#3/0 AWG), black XLPE insulation for enhanced thermal, abrasion, and environmental resistance, plus a bare ACSR neutral messenger (#3/0 AWG), it ensures efficient conductivity, corrosion resistance, and structural integrity. Rated 600V phase-to-phase up to 90°C (XLPE), with ≈275A ampacity, it meets ASTM B-230/B-231/B-232/B-399 and ICEA S-76-474. The balanced, lightweight design facilitates easy installation while offering robust protection against extreme outdoor conditions such as temperature swings, moisture, UV exposure, and mechanical stress in residential, commercial, and light industrial applications.
4/0 Arca Aluminum Conductor Triplex Overhead Service Drop Cable
4/0-4/0-2/0 Arca Aluminum Conductor Triplex Overhead Service Drop Cable is engineered for high-capacity overhead power delivery from utility poles to residential, commercial, or light industrial weatherheads. It features concentric-lay-stranded 1350-H19 aluminum phase conductors (#4/0 AWG, 19-strand), black cross-linked polyethylene (XLPE) insulation for superior weather, UV, and thermal resistance, and a bare ACSR neutral messenger (#2/0 AWG, 7-strand) for mechanical support and conductivity. Rated for 600 volts phase-to-phase at conductor temperatures up to 90°C (XLPE) or 75°C (Poly), it provides an allowable ampacity of approximately 315 amps (XLP). Compliant with ASTM B-230, B-231, B-232, B-399, and ICEA S-76-474 standards, this robust, lightweight cable ensures easy installation, excellent electrical performance, and long-term durability in harsh outdoor environments, including wind, ice, moisture, and temperature extremes.In-Depth Analysis
Comparative Analysis of Efficiency and Loss
Compared to the industry average, NPC Overhead Insulated Cable exhibit lower losses and higher efficiency across the entire load range.
Load Efficiency Comparison(%)
No-load Loss Comparison(W)
High Conductivity Design
High-purity oxygen-free copper or high-quality aluminum conductors are used with smooth surface and low resistance to ensure efficient power transmission and reduce energy loss.
Insulation Protection System
Use flame-retardant, wear-resistant and corrosion-resistant polymer insulation materials to meet the safe operation requirements in different environments.
Weather-Resistant & Durable Technology
The outer sheath is made of UV-resistant, heat-resistant, and oil-resistant materials, making it suitable for high and low temperatures, humidity, and long-term outdoor use.
Safe Flame Retardant System
The multi-layered flame-retardant structure effectively slows the spread of flames and releases low-smoke, halogen-free gases during combustion, reducing secondary hazards.
Easy Installation & Maintenance
The flexible core and flex-resistant outer sheath provide a small bend radius and high installation efficiency. Color coding and length markings reduce installation and maintenance costs.
Intelligent Monitoring
An optional remote monitoring system is available to monitor operating status, temperature, load and other parameters in real time, and supports fault warning and remote diagnosis.
Environmental Adaptability Analysis
NPC Overhead Insulated Cable have been rigorously tested and can operate stably under various harsh environmental conditions.
Temperature Range
-40℃ ~ +55℃
Can work normally in extreme high and low temperature environments
Humidity Adaptation
0 ~ 100% RH
Including condensation environment, no frost requirement
Weather Resistance Grade
UV/IEC 60811-501
The outer sheath has excellent UV resistance and aging resistance
Chemical Corrosion Resistance
Oil / Acid / Alkali
Resistant to oil, acid, alkali and some chemical corrosion environments
Why Choose Us
Overhead Insulated Cable Manufacturer
Overhead Insulated Cable Benefits
Overhead Insulated Cable Installation
Testing and Certification
Product Show
Testing and Certification
Bare Cable Test Report
SGS Inspection Report
Certificate of Acceptance
ISO Quality Certificate
ISO Environmental Certificate
ISO Occupational Certificate
UL Laboratory Certificate
UL Product Certificate
Project Cases
Peru Solar PV Project
CompletedNPC Electric Delivers Medium-Voltage Cables for Peru Solar PV Project
Country:Peru
Model:HEPRZ1(AS) 1x630 mm² 19/33kV x 6km
Chile El Project
CompletedReliable 19/33kV MV cables ensuring safe, stable, and efficient power transmission for critical projects.
Country:Chile
Model:19/33kV MV Power Cables x 5km
Dominican Edenorte Project
CompletedProvide outdoor power solutions for urban main road reconstruction projects to adapt to complex environments.
Country:Dominican
Model:NPC AAAC Cable & Triplex Cable x 10km
Technical Advantages
FAQ From Customers
-
What is the structure of an overhead insulated cable?
Overhead insulated cables typically consist of a conductor, insulation layer, and an optional outer sheath. The conductor is usually made from aluminum or copper, providing excellent electrical conductivity. The insulation layer, made from materials like cross-linked polyethylene (XLPE) or PVC, protects the conductor and prevents accidental contact with live wires. An optional outer sheath is added for additional mechanical protection and durability, particularly in harsh environmental conditions. -
What materials are used for the insulation of overhead insulated cables?
The insulation of overhead insulated cables is typically made from cross-linked polyethylene (XLPE), which offers superior thermal stability, electrical insulation properties, and resistance to environmental factors. Alternatively, PVC (polyvinyl chloride) can be used for lower voltage applications. These materials help prevent electrical hazards by ensuring that the conductor remains safely insulated, especially in outdoor and exposed environments such as overhead power lines. -
How are overhead insulated cables manufactured?
The manufacturing process of overhead insulated cables begins with the conductor preparation, which involves drawing aluminum or copper to the desired size. The insulation layer is then applied using extrusion technology, ensuring uniform thickness and durability. For high voltage cables, the insulation is cross-linked to improve performance at elevated temperatures and resist electrical stress. The outer sheath is then added, providing protection against physical damage and environmental conditions. The entire process follows stringent quality control and testing procedures to ensure reliability and compliance with international standards such as IEC and ANSI. -
What makes overhead insulated cables suitable for high voltage applications?
Overhead insulated cables are suitable for high voltage applications due to their specialized insulation materials such as cross-linked polyethylene (XLPE), which provides excellent electrical strength and thermal stability. These materials prevent the risk of electrical leakage and offer protection against high voltage surges. The cables' mechanical strength and weather-resistant outer sheath ensure long-term durability and performance, even in extreme environments. Additionally, the insulated layers prevent external damage from wind, moisture, and physical contact, making them ideal for high-voltage power transmission. -
How do overhead insulated cables protect against environmental factors?
Overhead insulated cables are designed to withstand environmental challenges such as moisture, extreme temperatures, UV radiation, and mechanical stress. The insulation material, typically XLPE or PVC, offers excellent resistance to corrosion and weathering, ensuring long-lasting performance even in harsh climates. The outer sheath further protects the cable from abrasion, chemical exposure, and physical damage, ensuring that the cables maintain their integrity and electrical safety during their service life.