Wires and Cables
Rubber Cable
H07RN-F AD8 EN 50525-2-21 Flexible Rubber Cable
H07RN-F AD8 Rubber-Sheathed Flexible Cable is a heavy-duty rubber cable compliant with EN 50525-2-21 and rated at 450/750V (up to 1kV in fixed installations). Constructed with EPR insulation and a PCP outer sheath, it offers excellent resistance to oil, abrasion, weather, and mechanical stress. With its AD8 water immersion rating, this cable is ideal for long-term use in wet or submerged environments, making it suitable for construction sites, mobile power supplies, industrial equipment, ports, stages, drainage systems, and water treatment facilities. It also meets flame retardant requirements per IEC/EN 60332-1-2, ensuring safety and reliability under harsh operating conditions.
H07ZZ-F EN 50525-3-21 LSZH Rubber Flexible Cable
The H07ZZ-F Rubber Flexible Cable is a high-performance low-smoke, halogen-free (LSZH) flexible cable designed in compliance with EN 50525-3-21 and IEC 60502-1 standards. It offers outstanding flexibility, flame retardancy, and resistance to smoke and toxic gas emission, ensuring enhanced safety in public and industrial environments. With its cross-linked LSZH insulation and sheath, the H07ZZ-F cable is ideal for fixed and mobile electrical installations in airports, subways, public buildings, power distribution systems, UPS equipment, and stage lighting setups. Engineered to perform under moderate mechanical stress, it maintains excellent reliability both indoors and outdoors.
H07RN-8-F EN 50525-2-21 Flexible Rubber Cable
The H07RN-8-F EN 50525-2-21 Flexible Rubber Cable is a high-performance flexible power cable designed for demanding environments. Complying with IEC 60245 and EN 50525-2-21 standards, it features a weather-resistant and oil-resistant rubber sheath that provides superior flexibility and durability under mechanical, thermal, and chemical stress. The H07RN-8-F cable is suitable for dry, wet, or submerged conditions, making it ideal for mobile power supply, submersible pumps (up to 10 meters depth in freshwater), construction sites, industrial workshops, agricultural machinery, and temporary outdoor installations. It ensures reliable energy transmission even in harsh environments and explosive zones.
Coil End Lead Type 4 BS 6195 Cable
The Coil End Lead Type 4 BS 6195 Cable is a high-performance flexible cable designed specifically for motor coil end connections and generator winding leads. Manufactured in compliance with BS 6195 and EN 60228 standards, this cable provides excellent heat resistance, oil resistance, and mechanical strength, ensuring reliable performance in demanding electrical environments. With EPR-HOFR insulation and a CPE rubber sheath, the Coil End Lead Type 4 cable delivers exceptional durability and flexibility. It is ideal for use in motors, generators, transformers, circuit breakers, and actuators, and can serve as a replacement for tri-rated or bi-rated cables when enhanced reliability is required. Available in multiple voltage classes (from 300/500V up to 6.35/11kV), it is suitable for both fixed and flexible installations under thermal and mechanical stress.
NSGAFQU 1.8/3kV Rubber Cable
NSGAFÖU 1.8/3kV Rubber Cable complies with the international VDE 0250 standard and utilizes heat-resistant rubber insulation. It offers excellent flexibility, oil resistance, and mechanical resistance. This cable is suitable for internal wiring in high-temperature, high-voltage environments such as motors, switchgear, and railway locomotives.
0361TQ BS 638 Black Welding Cable
H07RN-F AD8 Rubber-Sheathed Flexible Cable is a heavy-duty rubber cable compliant with EN 50525-2-21 and rated at 450/750V (up to 1kV in fixed installations). Constructed with EPR insulation and a PCP outer sheath, it offers excellent resistance to oil, abrasion, weather, and mechanical stress. With its AD8 water immersion rating, this cable is ideal for long-term use in wet or submerged environments, making it suitable for construction sites, mobile power supplies, industrial equipment, ports, stages, drainage systems, and water treatment facilities. It also meets flame retardant requirements per IEC/EN 60332-1-2, ensuring safety and reliability under harsh operating conditions.
0361TQ BS 638 Orange Welding Cable
H07RN-F AD8 Rubber-Sheathed Flexible Cable is a heavy-duty rubber cable compliant with EN 50525-2-21 and rated at 450/750V (up to 1kV in fixed installations). Constructed with EPR insulation and a PCP outer sheath, it offers excellent resistance to oil, abrasion, weather, and mechanical stress. With its AD8 water immersion rating, this cable is ideal for long-term use in wet or submerged environments, making it suitable for construction sites, mobile power supplies, industrial equipment, ports, stages, drainage systems, and water treatment facilities. It also meets flame retardant requirements per IEC/EN 60332-1-2, ensuring safety and reliability under harsh operating conditions.
H01N2-D EN 50525-2-81 Welding Cable
The H01N2-D EN 50525-2-81 Welding Cable is a high-performance flexible cable designed specifically for welding and heavy-duty industrial applications. Manufactured in compliance with EN 50525-2-81, this cable features a Class 6 finely stranded copper conductor that provides excellent flexibility and conductivity. Its durable rubber compound sheath ensures outstanding resistance to heat, oil, abrasion, ozone, and mechanical stress, making it ideal for demanding work environments. Engineered for connecting welding equipment, mobile power supplies, and robotic welding systems, the H01N2-D cable ensures safe, stable high-current transmission even under extreme operating conditions. It is widely used in automotive manufacturing, shipbuilding, battery energy storage systems (BESS), and industrial workshops. With its superior flexibility, the cable can withstand frequent movement and bending, reducing fatigue during use. It maintains reliable performance across a wide temperature range from -40°C to +85°C, offering consistent electrical integrity in both fixed and flexed installations. Complying with international standards such as EN 50525-2-81, EN 60228, VDE 0282-6, and BS 638 Part 4, the H01N2-D cable also meets IEC/EN 60332-1-2 flame-retardant requirements, ensuring safety in high-risk industrial environments.In-Depth Analysis
Comparative Analysis of Efficiency and Loss
Compared to the industry average, NPC wires and cables exhibit lower losses and higher efficiency across the entire load range.
Load Efficiency Comparison(%)
No-load Loss Comparison(W)
High Conductivity Design
High-purity oxygen-free copper or high-quality aluminum conductors are used with smooth surface and low resistance to ensure efficient power transmission and reduce energy loss.
Insulation Protection System
Use flame-retardant, wear-resistant and corrosion-resistant polymer insulation materials to meet the safe operation requirements in different environments.
Weather-Resistant & Durable Technology
The outer sheath is made of UV-resistant, heat-resistant, and oil-resistant materials, making it suitable for high and low temperatures, humidity, and long-term outdoor use.
Safe Flame Retardant System
The multi-layered flame-retardant structure effectively slows the spread of flames and releases low-smoke, halogen-free gases during combustion, reducing secondary hazards.
Easy Installation & Maintenance
The flexible core and flex-resistant outer sheath provide a small bend radius and high installation efficiency. Color coding and length markings reduce installation and maintenance costs.
Intelligent Monitoring
An optional remote monitoring system is available to monitor operating status, temperature, load and other parameters in real time, and supports fault warning and remote diagnosis.
Environmental Adaptability Analysis
NPC wires and cables have been rigorously tested and can operate stably under various harsh environmental conditions.
Temperature Range
-40℃ ~ +55℃
Can work normally in extreme high and low temperature environments
Humidity Adaptation
0 ~ 100% RH
Including condensation environment, no frost requirement
Weather Resistance Grade
UV/IEC 60811-501
The outer sheath has excellent UV resistance and aging resistance
Chemical Corrosion Resistance
Oil / Acid / Alkali
Resistant to oil, acid, alkali and some chemical corrosion environments
Why Choose Us
Wires & Cables Manufacturer
Wires & Cables Products
Wires & Cables Testing
Efficient Logistics & Timely Delivery
Testing and Certification
Bare Cable Test Report
SGS Inspection Report
Certificate of Acceptance
ISO Quality Certificate
ISO Environmental Certificate
ISO Occupational Certificate
UL Laboratory Certificate
UL Product Certificate
Project Cases
Peru Solar PV Project
CompletedNPC Electric Delivers Medium-Voltage Cables for Peru Solar PV Project
Country:Peru
Model:HEPRZ1(AS) 1x630 mm² 19/33kV x 6km
Chile El Project
CompletedReliable 19/33kV MV cables ensuring safe, stable, and efficient power transmission for critical projects.
Country:Chile
Model:19/33kV MV Power Cables x 5km
Dominican Edenorte Project
CompletedProvide outdoor power solutions for urban main road reconstruction projects to adapt to complex environments.
Country:Dominican
Model:NPC AAAC Cable & Triplex Cable x 10km
Technical Advantages
FAQ From Customers
-
What is the difference between wires and cables?
A wire is a single conductor that carries electricity, while a cable is a group of two or more insulated electrical wires bundled together. Wires and cables are used to transmit electrical power or signals, but cables provide better protection and are often used where safety and durability are critical. -
How do I choose the right electrical cable for my project?
When selecting an electrical cable, consider the required voltage, current capacity, installation environment, and safety standards. For example, choose power cables for high-load transmission, solar cables for photovoltaic systems, or insulated electrical wires for indoor wiring. Always ensure the cable meets international standards such as IEC, UL, or ISO. -
What are the common types of wires and cables?
Common types include bare conductor cables for overhead transmission, power cables for industrial and residential electricity supply, solar cables for renewable energy systems, insulated cables for building wiring, grounding wires for safety, and submarine cables for undersea power transmission. -
Why is testing important for electrical wires and cables?
Testing ensures wires and cables meet safety, durability, and performance standards. High-quality electrical cables undergo conductivity, insulation, fire resistance, and mechanical strength tests to guarantee reliable operation. Properly tested electrical wires reduce energy loss, prevent short circuits, and increase system safety. -
Can NPC Electric provide customized wires and cables solutions?
Yes. With over 30 years of manufacturing experience, NPC Electric offers customized wires and cables, including electrical cables and electrical wires designed to specific voltage levels, insulation types, and installation conditions. Our engineering team supports custom solutions for power transmission, industrial automation, renewable energy, and infrastructure projects worldwide.