Wires and Cables
Building Wire
Why Choose Us
As a trusted partner in energy savings and the development of green energy solutions, NPC
Electric has played a pioneering role in the development of national smart grids across
multiple regions.

Project Experience
With years of experience in power transmission and distribution, NPC Electric has become
a trusted name in the manufacturing of cables and transformers. We’ve successfully
served international EPC companies such as Elecnor, Cobra, and Equans in Latin America,
Africa, and Southeast Asia.We have provided the 132kV Power Transformer,Pad Mounted
Transformer and Earth Transformer.

Technical Support
NPC Electric’s skilled engineers offer full-cycle support—from design consultation and
technical drawings to on-site guidance and after-sales service—ensuring peace of mind at
every stage of the project.
We have a technical team of over 60 members and more than 100 after-sales engineers,
ready to assist customers with installation and on-site support.
Till now, we have provided professional engineering services in countries such as
Mongolia, Honduras, Peru, and Rwanda. Our services include winding resistance testing,
oil testing, and installation support.

Quality Control
NPC Electric uses high-quality raw materials and advanced production processes,
supported by strict quality control systems. Our products meet or exceed international
standards such as IEC, UL, and ISO, ensuring safety, reliability, and long service life.
All our cables are subject to third-party laboratory testing—such as by SGS, DNV, or
witnessed directly by customers—to ensure compliance and performance.

Efficient Logistics & Timely Delivery
With over 4,200 sqm of warehouse space and a strategic in China, we guarantee timely
delivery and flexible logistics to meet tight project schedules globally.We have the
professional team to assitance the customer to ship the production, we can do
EXW,CIF,FOB,FCA,CIP or any customer request terms.
Technical Advantages
● 30+ years of manufacturing experience
● ISO and UL certified production
● Customized cable and transformer solutions
FAQ From Customers
-
What are the advantages of power cables and overhead lines?(1) Reliable operation, because it is installed in a hidden place such as underground, it is less damaged by external forces, has less chance of failure, and the power supply is safe, and it will not cause harm to people; (2) The maintenance workload is small and frequent inspections are not required; (3) No need to erect towers; (4) Help improve power factor.
-
Which aspects should be considered when choosing the cross section of a power cable?(1) The long-term allowable working current of the cable; (2) Thermal stability once short circuited; (3) The voltage drop on the line cannot exceed the allowable working range.
-
What are the measures for cable fire prevention?(1) Use flame-retardant cables; (2) Use fireproof cable tray; (3) Use fireproof paint; (4) Fire partition walls and fire baffles are installed at cable tunnels, mezzanine exits, etc.; (5) Overhead cables should avoid oil pipelines and explosion-proof doors, otherwise local pipes or heat insulation and fire prevention measures should be taken.
-
What should be paid attention to during the transportation and handling of cables?(1) During transportation, loading and unloading, cables and cable reels should not be damaged. It is strictly forbidden to push the cable reels directly from the vehicle. Generally, cables should not be transported and stored flat. (2) Before transporting or rolling the cable reel, ensure that the cable reel is firm, the cable is wound tightly, the oil pipe between the oil-filled cable and the pressure oil tank should be fixed without damage, the pressure oil tank should be firm, and the pressure indication should meet the requirements.
-
What inspections should be carried out for the acceptance of cable lines?(1) The cable specifications should meet the regulations, the arrangement should be neat, no damage, and the signs should be complete, correct and clear; (2) The fixed bending radius of the cable, the related distance and the wiring of the metal sheath of the single-core power cable should meet the requirements; (3) The cable terminal and the middle head should not leak oil, and the installation should be firm. The oil pressure of the oil-filled cable and the meter setting should meet the requirements; (4) Good grounding; (5) The color of the cable terminal is correct, and the metal parts such as the bracket are completely painted; (6) There should be no debris in the cable trench, tunnel, and bridge, and the cover should be complete.
Welcome your inquiry
Honesty, Integrity, Frugality, Activeness and Passion