x
1/0 Purpura Aluminum Conductor Triplex Overhead Service Drop Cable
1/0 Purpura Aluminum Conductor Triplex Overhead Service Drop Cable

1/0 Purpura Aluminum Conductor Triplex Overhead Service Drop Cable

1/0 Purpura Triplex Aluminum Conductor Overhead Service Drop Cable is a durable and reliable aerial cable designed to deliver 600V power from utility lines to residential, commercial, or light industrial premises through a weatherhead service entrance. It consists of two insulated phase conductors and one bare neutral messenger, cabled together in a triplex configuration. The conductors are made of 1350-H19 aluminum, insulated with black cross-linked polyethylene (XLPE) for enhanced performance in extreme weather conditions, UV exposure, and mechanical stress.
Construction
Technical Specifications
Quality Control
Application

Construction

1/0 Purpura Aluminum Conductor Triplex Overhead Service Drop Cable Constrution
1/0 Purpura Aluminum Conductor Triplex Overhead Service Drop Cable

Standard

• ASTM B-230 Aluminum Wire, 1350-H19 for Electrical Purposes.
• ASTM B-231 Aluminum Conductors, Concentric-Lay-Stranded.
• ASTM B-232 Aluminum Conductors, Concentric-Lay-Stranded, Coated Steel Reinforced (ACSR).
• ASTM B-399 Concentric-Lay-Stranded 6201-T81 Aluminum Alloy Conductors.
• ICEA S-76-474-Neutral-supported Power Cable Assemblies With Weather-Resistant Extruded Insulation Rated 600 Volts.

Phase Conductor

Strand or Compressed 1350-H19 Series Aluminum Conductor.

Neutral (Messenger) Conductor

Bare AAC messenger. Optional constructions include a messenger of ACSR or 6201 alloy.

Insulation

Black Cross Linked Polyethylene (XLP) Insulation.

Application

1/0 Purpura Triplex aluminum wire has three conductors, with one of them being for neutral path, and two electrodes. The aluminum triplex cable is an electrical cable meant for power distributions from the utility lines to the consumer’s premises through the weather head. To be used at voltages of 600 volts phase-to-phase or less and at conductor temperatures not to exceed 75°C for polyethylene insulated conductors or 90°C for cross-linked polyethylene (XLPE) insulated conductors.A bare messenger wire of this electrical cable is bonded closely on the two insulated aluminum conductors, which are individually insulated with black cross-linked polyethylene for protection.

Installation Guidelines

1. For aerial use only – not suitable for underground installations
2. Ideal for pole-to-structure connections
3. Maintain proper clearances and sag as per NEC or local code
4. Avoid mechanical strain during installation
5. Operating range: -40°C to +90°C (with XLPE)

Key Features

1. Voltage rating: 600 volts
2. Temperature rating: 75°C (PE), 90°C (XLP)
3. Conductors: 1350-H19 Aluminum, stranded or compressed
4. Bare AAAC messenger for neutral and support
5. Insulation: Black cross-linked polyethylene (XLP), UV and weather resistant
6. Lightweight yet durable for easy aerial installation

Technical Specifications

1/0 Purpura Aluminum Conductor Triplex Overhead Service Drop Cable
1/0 Purpura Aluminum Conductor Triplex Overhead Service Drop Cable
Rated voltage V 600
Test voltage Veff kV/Hz 4/50
Laying temperature °C min. -5
Operating temperature °C -30 ~ +90
Conductor temperature °C max. +90
Short-circuit temperature °C/s max. +250 /5
Bending radius (min.) mm 20 × Ø of cable

Quality Control

1/0 Purpura Aluminum Conductor Triplex Overhead Service Drop Cable
1/0 Purpura Aluminum Conductor Triplex Overhead Service Drop Cable Material Test

Raw Material Test

NPC has always chosen raw material suppliers who have a good reputation, possess stable supply capabilities and have passed international quality system certifications (such as ISO 9001). And establish a long-term cooperative relationship with it, forming a stable and reliable raw material supply chain.
We will ensure that all raw materials are subject to strict inspection procedures upon entry to the factory, and can only be stored in the warehouse after they have been confirmed to meet the standards.

1/0 Purpura Aluminum Conductor Triplex Overhead Service Drop Cable Process inspection

Process inspection

NPC has strict quality control procedures for each process in the cable production process.
Process documents: Develop detailed process flow and operation instructions to clarify the operating specifications and quality standards of each process.
Equipment calibration: Regularly calibrate key equipment such as wire drawing machines, stranding machines, extruders, and diameter gauges to ensure that the accuracy meets the requirements.
First piece confirmation: Before each batch of production, the first piece is trial-produced to confirm that the process parameters, product dimensions, electrical performance, etc. meet the standards before mass production can be carried out.

1/0 Purpura Aluminum Conductor Triplex Overhead Service Drop Cable Finished Product

Finished Product

Inspectors conduct ex-factory inspections on cables according to relevant standards and corresponding product inspection specifications to ensure that each ex-factory product complies with the process regulations.

Application

1/0 Purpura Triplex aluminum wire has three conductors, with one of them being for neutral path, and two electrodes. The aluminum triplex cable is an electrical cable meant for power distributions from the utility lines to the consumer’s premises through the weather head.

Technical Advantages

● 30+ years of manufacturing experience
● ISO and UL certified production
● Customized cable and transformer solutions

Product Packaging

Wires and Cables packaging (1)
Wires and Cables packaging (1)
Wires and Cables packaging (2)
Wires and Cables packaging (2)
Wires and Cables packaging (3)
Wires and Cables packaging (3)
Wires and Cables packaging (4)
Wires and Cables packaging (4)
Wires and Cables packaging (5)
Wires and Cables packaging (5)
Wires and Cables packaging (6)
Wires and Cables packaging (6)
Wires and Cables packaging (7)
Wires and Cables packaging (7)
Wires and Cables packaging (8)
Wires and Cables packaging (8)

Related Products

FAQ From Customers

What are the advantages of power cables and overhead lines?
(1) Reliable operation, because it is installed in a hidden place such as underground, it is less damaged by external forces, has less chance of failure, and the power supply is safe, and it will not cause harm to people;
(2) The maintenance workload is small and frequent inspections are not required;
(3) No need to erect towers;
(4) Help improve power factor.
Which aspects should be considered when choosing the cross section of a power cable?
(1) The long-term allowable working current of the cable;
(2) Thermal stability once short circuited;
(3) The voltage drop on the line cannot exceed the allowable working range.
What are the measures for cable fire prevention?
(1) Use flame-retardant cables;
(2) Use fireproof cable tray;
(3) Use fireproof paint;
(4) Fire partition walls and fire baffles are installed at cable tunnels, mezzanine exits, etc.;
(5) Overhead cables should avoid oil pipelines and explosion-proof doors, otherwise local pipes or heat insulation and fire prevention measures should be taken.
What should be paid attention to during the transportation and handling of cables?
(1) During transportation, loading and unloading, cables and cable reels should not be damaged. It is strictly forbidden to push the cable reels directly from the vehicle. Generally, cables should not be transported and stored flat.
(2) Before transporting or rolling the cable reel, ensure that the cable reel is firm, the cable is wound tightly, the oil pipe between the oil-filled cable and the pressure oil tank should be fixed without damage, the pressure oil tank should be firm, and the pressure indication should meet the requirements.
What inspections should be carried out for the acceptance of cable lines?
(1) The cable specifications should meet the regulations, the arrangement should be neat, no damage, and the signs should be complete, correct and clear;
(2) The fixed bending radius of the cable, the related distance and the wiring of the metal sheath of the single-core power cable should meet the requirements;
(3) The cable terminal and the middle head should not leak oil, and the installation should be firm. The oil pressure of the oil-filled cable and the meter setting should meet the requirements;
(4) Good grounding;
(5) The color of the cable terminal is correct, and the metal parts such as the bracket are completely painted;
(6) There should be no debris in the cable trench, tunnel, and bridge, and the cover should be complete.

Welcome your inquiry

Honesty, Integrity, Frugality, Activeness and Passion