1/0 Neritina Aluminum Conductor Triplex Overhead Service Drop Cable
Construction
Standard
• ASTM B-231 Aluminum Conductors, Concentric-Lay-Stranded.
• ASTM B-232 Aluminum Conductors, Concentric-Lay-Stranded, Coated Steel Reinforced (ACSR).
• ASTM B-399 Concentric-Lay-Stranded 6201-T81 Aluminum Alloy Conductors.
• ICEA S-76-474-Neutral-supported Power Cable Assemblies With Weather-Resistant Extruded Insulation Rated 600 Volts.
Phase Conductor
Neutral (Messenger) Conductor
Insulation
Application
Typical Applications
2. Ideal for residential service entrances
3. Outdoor low-voltage distribution networks
4. Applications requiring UV, abrasion, and moisture resistance
Key Features
2. Temperature rating: 75°C (PE), 90°C (XLP)
3. Conductors: 1350-H19 Aluminum, stranded or compressed
4. Bare AAAC messenger for neutral and support
5. Insulation: Black cross-linked polyethylene (XLP), UV and weather resistant
6. Lightweight yet durable for easy aerial installation
Technical Specifications
| Rated voltage | V | 600 |
| Test voltage | Veff kV/Hz | 4/50 |
| Laying temperature | °C | min. -5 |
| Operating temperature | °C | -30 ~ +90 |
| Conductor temperature | °C | max. +90 |
| Short-circuit temperature | °C/s | max. +250 /5 |
| Bending radius (min.) | mm | 20 × Ø of cable |
Quality Control
Raw Material Test
The Raw Material Test is the first quality assurance step for the 1/0 Neritina Aluminum Conductor Triplex Overhead Service Drop Cable. Aluminum rods are inspected for chemical composition, electrical conductivity, tensile strength, and elongation to ensure compliance with applicable standards. Insulation compounds are tested for thermal stability, mechanical strength, weather resistance, and aging performance. Surface finish and dimensional consistency of all incoming materials are carefully verified. Each batch is logged and traceable throughout production. Only approved materials are released for manufacturing, ensuring consistent electrical reliability and mechanical durability in the finished 1/0 Neritina Aluminum Conductor Triplex Overhead Service Drop Cable.
Process inspection
Process Inspection ensures manufacturing consistency of the 1/0 Neritina Aluminum Conductor Triplex Overhead Service Drop Cable at every stage. During wire drawing, conductor diameter, roundness, and surface smoothness are continuously monitored. Insulation extrusion parameters, including thickness uniformity and concentricity, are checked in real time. During stranding, lay length, strand tension, and alignment are inspected to maintain structural balance and flexibility. These controls ensure uniform electrical performance, mechanical stability, and long-term service reliability.
Finished Product
The Finished Product Test verifies the final quality of the 1/0 Neritina Aluminum Conductor Triplex Overhead Service Drop Cable before shipment. Electrical resistance tests confirm conductivity, while tensile and elongation tests validate mechanical strength. Insulation integrity, dimensional accuracy, marking clarity, and visual appearance are inspected. Packaging integrity is also checked to ensure safe transportation and storage. Only fully compliant products are approved for delivery. Additional inspections include insulation integrity, dimensional checks, visual inspection, marking verification, and packaging examination before release.
Application
Technical Advantages
Product Packaging
Related Products
FAQ From Customers
-
What are the advantages of power cables and overhead lines?(1) Reliable operation, because it is installed in a hidden place such as underground, it is less damaged by external forces, has less chance of failure, and the power supply is safe, and it will not cause harm to people; (2) The maintenance workload is small and frequent inspections are not required; (3) No need to erect towers; (4) Help improve power factor.
-
Which aspects should be considered when choosing the cross section of a power cable?(1) The long-term allowable working current of the cable; (2) Thermal stability once short circuited; (3) The voltage drop on the line cannot exceed the allowable working range.
-
What are the measures for cable fire prevention?(1) Use flame-retardant cables; (2) Use fireproof cable tray; (3) Use fireproof paint; (4) Fire partition walls and fire baffles are installed at cable tunnels, mezzanine exits, etc.; (5) Overhead cables should avoid oil pipelines and explosion-proof doors, otherwise local pipes or heat insulation and fire prevention measures should be taken.
-
What should be paid attention to during the transportation and handling of cables?(1) During transportation, loading and unloading, cables and cable reels should not be damaged. It is strictly forbidden to push the cable reels directly from the vehicle. Generally, cables should not be transported and stored flat. (2) Before transporting or rolling the cable reel, ensure that the cable reel is firm, the cable is wound tightly, the oil pipe between the oil-filled cable and the pressure oil tank should be fixed without damage, the pressure oil tank should be firm, and the pressure indication should meet the requirements.
-
What inspections should be carried out for the acceptance of cable lines?(1) The cable specifications should meet the regulations, the arrangement should be neat, no damage, and the signs should be complete, correct and clear; (2) The fixed bending radius of the cable, the related distance and the wiring of the metal sheath of the single-core power cable should meet the requirements; (3) The cable terminal and the middle head should not leak oil, and the installation should be firm. The oil pressure of the oil-filled cable and the meter setting should meet the requirements; (4) Good grounding; (5) The color of the cable terminal is correct, and the metal parts such as the bracket are completely painted; (6) There should be no debris in the cable trench, tunnel, and bridge, and the cover should be complete.