NA2XSH Medium Voltage Power Cable(6/10kV, 12/20kV, 18/30kV)
The NA2XSH is a low-smoke halogen-free (LSZH), medium-voltage aluminum conductor cable with excellent flame retardant properties and meets the design requirements of the IEC 60502-2 standard. It is suitable for fixed laying environments with high requirements for fire safety and toxic smoke emission control such as industrial facilities, power stations, public buildings and subways. Its armored construction provides good mechanical protection and is suitable for direct burial or other high mechanical stress applications.
NA2XSY Medium Voltage Power Cable(6/10kV, 12/20kV, 18/30kV)
NA2XSY are medium voltage power cables with aluminum conductors and XLPE insulation, designed according to IEC 60502-2 standards. Suitable for fixed installations in power distribution networks, both indoors and outdoors, including underground systems where mechanical protection is not required.
RHZ1-2OL(AS)-AL Medium Voltage Power Cable(8.7/15kV, 12/20kV, 18/30kV Specifications)
RHZ1-2OL(AS)-AL are enhanced flame-retardant, low smoke, zero halogen (LSZH) medium voltage cables with aluminum conductors, manufactured under IEC 60502-2 standards. They feature a double layer of insulation for improved electrical performance and are intended for permanent installations in critical infrastructure such as subways, hospitals, and data centers where superior fire resistance and minimal emission of toxic gases are essential.
RHZ1-2OL(S)-AL Medium Voltage Power Cable(8.7/15kV, 12/20kV, 18/30kV Specifications)
RHZ1-2OL(S)-AL are flame-retardant, low smoke, zero halogen (LSZH) medium voltage cables with aluminum conductors and double layer insulation, manufactured according to IEC 60502-2 standards. They are specifically designed for fixed installations in energy-intensive environments such as power plants, substations, and industrial complexes, where enhanced electrical performance, high fire safety, and low toxic gas emissions are essential.
RHZ1-2OL-AL Medium Voltage Power Cable(8.7/15kV, 12/20kV, 18/30kV)
RHZ1-2OL-AL are flame-retardant, low smoke, zero halogen (LSZH) medium voltage cables with aluminum conductors and double-layer metallic armor, manufactured in compliance with IEC 60502-2. They are intended for fixed installations in demanding environments such as industrial complexes, underground infrastructure, and areas with increased risk of mechanical damage, where enhanced fire safety and minimal toxic emissions are required.
RHZ1-AL Medium Voltage Power Cable(8.7/15kV, 12/20kV, 18/30kV)
RHZ1-AL are flame-retardant, low smoke, zero halogen (LSZH) medium voltage cables with aluminum conductors, manufactured in accordance with IEC 60502-2. They are suitable for fixed installations in commercial and industrial environments where fire safety, reduced smoke emissions, and non-corrosive gases are essential, such as in energy distribution networks, public infrastructure, and indoor substations.
RHZ1-OL(AS)-AL Medium Voltage Power Cable(8.7/15kV, 12/20kV, 18/30kV)
RHZ1-OL(AS)-AL are flame-retardant, low smoke, zero halogen (LSZH) medium voltage cables with aluminum conductors, designed according to European standards. They are suitable for fixed installations in industrial facilities, tunnels, and public buildings, especially in environments requiring high fire safety and low toxic emissions.
RHZ1-OL-AL Medium Voltage Power Cable(8.7/15kV, 12/20kV, 18/30kV)
RHZ1-OL-AL are halogen-free, flame-retardant medium voltage cables with aluminum conductors, manufactured in compliance with IEC 60502-2. Designed for fixed installations, they are suitable for use in industrial plants, energy infrastructure, and public facilities where reduced smoke emission and low toxicity in case of fire are important. The design ensures reliable performance in environments where fire protection is a key requirement, though less demanding than applications requiring armoured or reinforced cables.
XAI Armoured Medium Voltage Power Cable(6/10kV, 12/20kV, 18/30kV)
XAI Armoured Cable are medium voltage power cables with copper conductors, XLPE insulation, and aluminum wire armour, designed for reliable energy transmission in demanding environments. Suitable for fixed installations in industrial networks, underground systems, and outdoor areas where mechanical protection is required.In-Depth Analysis
Comparative Analysis of Efficiency and Loss
Compared to the industry average, NPC wires and cables exhibit lower losses and higher efficiency across the entire load range.
Load Efficiency Comparison(%)
No-load Loss Comparison(W)
High Conductivity Design
High-purity oxygen-free copper or high-quality aluminum conductors are used with smooth surface and low resistance to ensure efficient power transmission and reduce energy loss.
Insulation Protection System
Use flame-retardant, wear-resistant and corrosion-resistant polymer insulation materials to meet the safe operation requirements in different environments.
Weather-Resistant & Durable Technology
The outer sheath is made of UV-resistant, heat-resistant, and oil-resistant materials, making it suitable for high and low temperatures, humidity, and long-term outdoor use.
Safe Flame Retardant System
The multi-layered flame-retardant structure effectively slows the spread of flames and releases low-smoke, halogen-free gases during combustion, reducing secondary hazards.
Easy Installation & Maintenance
The flexible core and flex-resistant outer sheath provide a small bend radius and high installation efficiency. Color coding and length markings reduce installation and maintenance costs.
Intelligent Monitoring
An optional remote monitoring system is available to monitor operating status, temperature, load and other parameters in real time, and supports fault warning and remote diagnosis.
Environmental Adaptability Analysis
NPC medium voltage power power cable have been rigorously tested and can operate stably under various harsh environmental conditions.
Temperature Range
-40℃ ~ +55℃
Can work normally in extreme high and low temperature environments
Humidity Adaptation
0 ~ 100% RH
Including condensation environment, no frost requirement
Weather Resistance Grade
UV/IEC 60811-501
The outer sheath has excellent UV resistance and aging resistance
Chemical Corrosion Resistance
Oil / Acid / Alkali
Resistant to oil, acid, alkali and some chemical corrosion environments
Why Choose Us
MV Power Cables Reliability
Optimized MV Power Cable Performance
Guaranteed Safety & Compliance
Testing & Quality Control
Product Show
Testing and Certification
Bare Cable Test Report
SGS Inspection Report
Certificate of Acceptance
ISO Quality Certificate
ISO Environmental Certificate
ISO Occupational Certificate
UL Laboratory Certificate
UL Product Certificate
Project Cases
Peru Solar PV Project
CompletedNPC Electric Delivers Medium-Voltage Cables for Peru Solar PV Project
Country:Peru
Model:HEPRZ1(AS) 1x630 mm² 19/33kV x 6km
Chile El Project
CompletedReliable 19/33kV MV cables ensuring safe, stable, and efficient power transmission for critical projects.
Country:Chile
Model:19/33kV MV Power Cables x 5km
Dominican Edenorte Project
CompletedProvide outdoor power solutions for urban main road reconstruction projects to adapt to complex environments.
Country:Dominican
Model:NPC AAAC Cable & Triplex Cable x 10km
Technical Advantages
FAQ From Customers
-
What is considered a medium voltage power cable?
A medium voltage power cable typically refers to cables that are used for power transmission and distribution at voltages ranging from 1kV to 35kV. These cables are designed to carry higher power loads over medium distances and are commonly used in substations, industrial plants, and commercial power systems. Medium voltage cables are essential for connecting high voltage transmission networks to low voltage distribution systems, ensuring efficient and safe power delivery across various sectors. -
What is the difference between low voltage and medium voltage power cables?
The main difference between low voltage and medium voltage cables lies in the voltage range and applications. Low voltage cables typically carry voltages up to 1kV and are used for residential, commercial, and small industrial installations. Medium voltage cables, on the other hand, carry voltages between 1kV and 35kV, making them ideal for power distribution networks and industrial applications that require more substantial power transmission over longer distances. Medium voltage cables also have more robust insulation and construction to handle higher electrical stresses. -
Where are medium voltage power cables used?
Medium voltage power cables are used in industrial, commercial, and utility applications for power distribution. They are commonly found in substations, underground power lines, and overhead power networks connecting high voltage transmission lines to residential or industrial areas. These cables are crucial for distributing power over larger distances and ensuring stable, efficient electricity delivery to businesses, factories, and large residential areas. -
What are the typical construction materials of medium voltage power cables?
Medium voltage power cables are typically constructed with copper or aluminum conductors for excellent electrical conductivity. The insulation is commonly made of cross-linked polyethylene (XLPE) or EPR (ethylene propylene rubber) to provide enhanced thermal stability and electrical performance. The sheath or outer layer is made from PVC or PE (polyethylene), which provides mechanical protection and ensures weather resistance. These materials ensure that medium voltage cables can handle high power loads while remaining durable and safe in various environments. -
What are the advantages of using medium voltage power cables?
Medium voltage power cables offer several key advantages:
1. Higher power capacity: They can handle larger electrical loads than low voltage cables, making them ideal for industrial applications and long-distance distribution.
2. Durability: Medium voltage cables are built to withstand mechanical stress, temperature variations, and environmental challenges, ensuring long-lasting performance.
3. Safety: The insulation used in medium voltage cables provides better protection against electrical faults, preventing risks such as electrical fires and short circuits in high-demand power systems.
4. Efficient power distribution: They play a crucial role in ensuring reliable and efficient delivery of electricity to various sectors, including utilities and manufacturing plants.