Wires and Cables
Wires and Cables
H-medium-voltage-power-cable.jpg)
N2XS(F)H Medium Voltage Power Cable (6/10kV, 12/20kV, 18/30kV)
N2XS(F)H are halogen-free, flame-retardant medium voltage power cables with copper conductors and cross-linked polyethylene (XLPE) insulation, designed in accordance with IEC 60502-2. These cables are especially suitable for fixed installations in buildings, underground systems, and energy networks where enhanced fire resistance, low smoke emission, and minimal corrosive gas release are required.H-medium-voltage-power-cable.jpg)
N2XS(FL)H Medium Voltage Power Cable(6/10kV, 12/20kV, 18/30kV)
N2XS(FL)H are flame-retardant, halogen-free, low smoke medium voltage cables with copper conductors, designed in compliance with VDE 0276-620 standards. These cables are particularly suitable for fixed installations in power plants, substations, and densely populated areas, where enhanced fire resistance, minimal smoke emission, and non-corrosive gas release are critical for safety.
N2XS2Y Medium Voltage Power Cable(6/10kV, 12/20kV, 18/30kV)
N2XS2Y is a medium voltage cable that complies with IEC 60502-2 standard, with copper conductor, cross-linked polyethylene (XLPE) insulation, polyethylene outer sheath and metal shielding structure. It is suitable for fixed laying in industrial facilities, distribution stations and underground cable channels, especially for application environments with high requirements for electrical performance and certain requirements for flame retardancy and water resistance
N2XSEY Medium Voltage Power Cable(6/10kV, 8.7/15KV,12/20kV, 18/30kV)
N2XSEY are medium voltage power cables with copper conductors, XLPE insulation, and PVC outer sheath, designed in accordance with VDE 0276-620 standards. They are suitable for indoor, outdoor, and underground installations, especially where moderate mechanical stress and good electrical performance are required.
N2XSH Medium Voltage Power Cable(6/10kV, 12/20kV, 18/30kV)
N2XSH are flame-retardant, low smoke, zero halogen (LSZH) medium voltage cables with copper conductors, manufactured according to IEC 60502-2 standards. They are suitable for fixed installations in power distribution networks, infrastructure projects, and commercial buildings, particularly where high safety requirements, fire resistance, and minimal smoke and corrosive gas emissions are essential.
N2XSY Medium Voltage Power Cable(6/10kV, 12/20kV, 18/30kV)
N2XSY are medium voltage power cables with copper conductors and cross-linked polyethylene (XLPE) insulation, designed according to DIN VDE 0276-620 standards. They are suitable for fixed installations in power distribution networks, industrial plants, and outdoor areas, providing reliable electrical performance and mechanical strength.
NA2XSH Medium Voltage Power Cable(6/10kV, 12/20kV, 18/30kV)
The NA2XSH is a low-smoke halogen-free (LSZH), medium-voltage aluminum conductor cable with excellent flame retardant properties and meets the design requirements of the IEC 60502-2 standard. It is suitable for fixed laying environments with high requirements for fire safety and toxic smoke emission control such as industrial facilities, power stations, public buildings and subways. Its armored construction provides good mechanical protection and is suitable for direct burial or other high mechanical stress applications.
NA2XSY Medium Voltage Power Cable(6/10kV, 12/20kV, 18/30kV)
NA2XSY are medium voltage power cables with aluminum conductors and XLPE insulation, designed according to IEC 60502-2 standards. Suitable for fixed installations in power distribution networks, both indoors and outdoors, including underground systems where mechanical protection is not required.-AL-medium-voltage-power-cable.jpg)
RHZ1-2OL(AS)-AL Medium Voltage Power Cable(8.7/15kV, 12/20kV, 18/30kV Specifications)
RHZ1-2OL(AS)-AL are enhanced flame-retardant, low smoke, zero halogen (LSZH) medium voltage cables with aluminum conductors, manufactured under IEC 60502-2 standards. They feature a double layer of insulation for improved electrical performance and are intended for permanent installations in critical infrastructure such as subways, hospitals, and data centers where superior fire resistance and minimal emission of toxic gases are essential.Why Choose Us
As a trusted partner in energy savings and the development of green energy solutions, NPC
Electric has played a pioneering role in the development of national smart grids across
multiple regions.

Project Experience
With years of experience in power transmission and distribution, NPC Electric has become
a trusted name in the manufacturing of cables and transformers. We’ve successfully
served international EPC companies such as Elecnor, Cobra, and Equans in Latin America,
Africa, and Southeast Asia.We have provided the 132kV Power Transformer,Pad Mounted
Transformer and Earth Transformer.

Technical Support
NPC Electric’s skilled engineers offer full-cycle support—from design consultation and
technical drawings to on-site guidance and after-sales service—ensuring peace of mind at
every stage of the project.
We have a technical team of over 60 members and more than 100 after-sales engineers,
ready to assist customers with installation and on-site support.
Till now, we have provided professional engineering services in countries such as
Mongolia, Honduras, Peru, and Rwanda. Our services include winding resistance testing,
oil testing, and installation support.

Quality Control
NPC Electric uses high-quality raw materials and advanced production processes,
supported by strict quality control systems. Our products meet or exceed international
standards such as IEC, UL, and ISO, ensuring safety, reliability, and long service life.
All our cables are subject to third-party laboratory testing—such as by SGS, DNV, or
witnessed directly by customers—to ensure compliance and performance.

Efficient Logistics & Timely Delivery
With over 4,200 sqm of warehouse space and a strategic in China, we guarantee timely
delivery and flexible logistics to meet tight project schedules globally.We have the
professional team to assitance the customer to ship the production, we can do
EXW,CIF,FOB,FCA,CIP or any customer request terms.
Technical Advantages
● 30+ years of manufacturing experience
● ISO and UL certified production
● Customized cable and transformer solutions
FAQ From Customers
-
What are the advantages of power cables and overhead lines?(1) Reliable operation, because it is installed in a hidden place such as underground, it is less damaged by external forces, has less chance of failure, and the power supply is safe, and it will not cause harm to people; (2) The maintenance workload is small and frequent inspections are not required; (3) No need to erect towers; (4) Help improve power factor.
-
Which aspects should be considered when choosing the cross section of a power cable?(1) The long-term allowable working current of the cable; (2) Thermal stability once short circuited; (3) The voltage drop on the line cannot exceed the allowable working range.
-
What are the measures for cable fire prevention?(1) Use flame-retardant cables; (2) Use fireproof cable tray; (3) Use fireproof paint; (4) Fire partition walls and fire baffles are installed at cable tunnels, mezzanine exits, etc.; (5) Overhead cables should avoid oil pipelines and explosion-proof doors, otherwise local pipes or heat insulation and fire prevention measures should be taken.
-
What should be paid attention to during the transportation and handling of cables?(1) During transportation, loading and unloading, cables and cable reels should not be damaged. It is strictly forbidden to push the cable reels directly from the vehicle. Generally, cables should not be transported and stored flat. (2) Before transporting or rolling the cable reel, ensure that the cable reel is firm, the cable is wound tightly, the oil pipe between the oil-filled cable and the pressure oil tank should be fixed without damage, the pressure oil tank should be firm, and the pressure indication should meet the requirements.
-
What inspections should be carried out for the acceptance of cable lines?(1) The cable specifications should meet the regulations, the arrangement should be neat, no damage, and the signs should be complete, correct and clear; (2) The fixed bending radius of the cable, the related distance and the wiring of the metal sheath of the single-core power cable should meet the requirements; (3) The cable terminal and the middle head should not leak oil, and the installation should be firm. The oil pressure of the oil-filled cable and the meter setting should meet the requirements; (4) Good grounding; (5) The color of the cable terminal is correct, and the metal parts such as the bracket are completely painted; (6) There should be no debris in the cable trench, tunnel, and bridge, and the cover should be complete.
Welcome your inquiry
Honesty, Integrity, Frugality, Activeness and Passion