N2XSY Medium Voltage Power Cable(6/10kV, 12/20kV, 18/30kV)
N2XSY are medium voltage power cables with copper conductors and cross-linked polyethylene (XLPE) insulation, designed according to DIN VDE 0276-620 standards. They are suitable for fixed installations in power distribution networks, industrial plants, and outdoor areas, providing reliable electrical performance and mechanical strength.
NA2XSH Medium Voltage Power Cable(6/10kV, 12/20kV, 18/30kV)
The NA2XSH is a low-smoke halogen-free (LSZH), medium-voltage aluminum conductor cable with excellent flame retardant properties and meets the design requirements of the IEC 60502-2 standard. It is suitable for fixed laying environments with high requirements for fire safety and toxic smoke emission control such as industrial facilities, power stations, public buildings and subways. Its armored construction provides good mechanical protection and is suitable for direct burial or other high mechanical stress applications.
NA2XSY Medium Voltage Power Cable(6/10kV, 12/20kV, 18/30kV)
NA2XSY are medium voltage power cables with aluminum conductors and XLPE insulation, designed according to IEC 60502-2 standards. Suitable for fixed installations in power distribution networks, both indoors and outdoors, including underground systems where mechanical protection is not required.
RHZ1-2OL(AS)-AL Medium Voltage Power Cable(8.7/15kV, 12/20kV, 18/30kV Specifications)
RHZ1-2OL(AS)-AL are enhanced flame-retardant, low smoke, zero halogen (LSZH) medium voltage cables with aluminum conductors, manufactured under IEC 60502-2 standards. They feature a double layer of insulation for improved electrical performance and are intended for permanent installations in critical infrastructure such as subways, hospitals, and data centers where superior fire resistance and minimal emission of toxic gases are essential.
RHZ1-2OL(S)-AL Medium Voltage Power Cable(8.7/15kV, 12/20kV, 18/30kV Specifications)
RHZ1-2OL(S)-AL are flame-retardant, low smoke, zero halogen (LSZH) medium voltage cables with aluminum conductors and double layer insulation, manufactured according to IEC 60502-2 standards. They are specifically designed for fixed installations in energy-intensive environments such as power plants, substations, and industrial complexes, where enhanced electrical performance, high fire safety, and low toxic gas emissions are essential.
RHZ1-2OL-AL Medium Voltage Power Cable(8.7/15kV, 12/20kV, 18/30kV)
RHZ1-2OL-AL are flame-retardant, low smoke, zero halogen (LSZH) medium voltage cables with aluminum conductors and double-layer metallic armor, manufactured in compliance with IEC 60502-2. They are intended for fixed installations in demanding environments such as industrial complexes, underground infrastructure, and areas with increased risk of mechanical damage, where enhanced fire safety and minimal toxic emissions are required.
RHZ1-AL Medium Voltage Power Cable(8.7/15kV, 12/20kV, 18/30kV)
RHZ1-AL are flame-retardant, low smoke, zero halogen (LSZH) medium voltage cables with aluminum conductors, manufactured in accordance with IEC 60502-2. They are suitable for fixed installations in commercial and industrial environments where fire safety, reduced smoke emissions, and non-corrosive gases are essential, such as in energy distribution networks, public infrastructure, and indoor substations.
RHZ1-OL(AS)-AL Medium Voltage Power Cable(8.7/15kV, 12/20kV, 18/30kV)
RHZ1-OL(AS)-AL are flame-retardant, low smoke, zero halogen (LSZH) medium voltage cables with aluminum conductors, designed according to European standards. They are suitable for fixed installations in industrial facilities, tunnels, and public buildings, especially in environments requiring high fire safety and low toxic emissions.
RHZ1-OL-AL Medium Voltage Power Cable(8.7/15kV, 12/20kV, 18/30kV)
RHZ1-OL-AL are halogen-free, flame-retardant medium voltage cables with aluminum conductors, manufactured in compliance with IEC 60502-2. Designed for fixed installations, they are suitable for use in industrial plants, energy infrastructure, and public facilities where reduced smoke emission and low toxicity in case of fire are important. The design ensures reliable performance in environments where fire protection is a key requirement, though less demanding than applications requiring armoured or reinforced cables.In-Depth Analysis
Comparative Analysis of Efficiency and Loss
Compared to the industry average, NPC wires and cables exhibit lower losses and higher efficiency across the entire load range.
Load Efficiency Comparison(%)
No-load Loss Comparison(W)
High Conductivity Design
High-purity oxygen-free copper or high-quality aluminum conductors are used with smooth surface and low resistance to ensure efficient power transmission and reduce energy loss.
Insulation Protection System
Use flame-retardant, wear-resistant and corrosion-resistant polymer insulation materials to meet the safe operation requirements in different environments.
Weather-Resistant & Durable Technology
The outer sheath is made of UV-resistant, heat-resistant, and oil-resistant materials, making it suitable for high and low temperatures, humidity, and long-term outdoor use.
Safe Flame Retardant System
The multi-layered flame-retardant structure effectively slows the spread of flames and releases low-smoke, halogen-free gases during combustion, reducing secondary hazards.
Easy Installation & Maintenance
The flexible core and flex-resistant outer sheath provide a small bend radius and high installation efficiency. Color coding and length markings reduce installation and maintenance costs.
Intelligent Monitoring
An optional remote monitoring system is available to monitor operating status, temperature, load and other parameters in real time, and supports fault warning and remote diagnosis.
Environmental Adaptability Analysis
NPC power cable have been rigorously tested and can operate stably under various harsh environmental conditions.
Temperature Range
-40℃ ~ +55℃
Can work normally in extreme high and low temperature environments
Humidity Adaptation
0 ~ 100% RH
Including condensation environment, no frost requirement
Weather Resistance Grade
UV/IEC 60811-501
The outer sheath has excellent UV resistance and aging resistance
Chemical Corrosion Resistance
Oil / Acid / Alkali
Resistant to oil, acid, alkali and some chemical corrosion environments
Why Choose Us
Power Cables Manufacturer
High, Medium, and Low Voltage Power Cables
Power Cable Design
Testing & Quality Control
Product Show
Testing and Certification
Bare Cable Test Report
SGS Inspection Report
Certificate of Acceptance
ISO Quality Certificate
ISO Environmental Certificate
ISO Occupational Certificate
UL Laboratory Certificate
UL Product Certificate
Project Cases
Peru Solar PV Project
CompletedNPC Electric Delivers Medium-Voltage Cables for Peru Solar PV Project
Country:Peru
Model:HEPRZ1(AS) 1x630 mm² 19/33kV x 6km
Chile El Project
CompletedReliable 19/33kV MV cables ensuring safe, stable, and efficient power transmission for critical projects.
Country:Chile
Model:19/33kV MV Power Cables x 5km
Dominican Edenorte Project
CompletedProvide outdoor power solutions for urban main road reconstruction projects to adapt to complex environments.
Country:Dominican
Model:NPC AAAC Cable & Triplex Cable x 10km
Technical Advantages
FAQ From Customers
-
What are high voltage power cables used for?
High-voltage power cables are designed for the transmission of electricity over long distances. They are used in high-voltage transmission lines to deliver electricity from power plants to substations. These cables are engineered to handle high electrical loads, minimize energy loss, and ensure safety in long-distance electrical power transmission. High-voltage cables are typically made with advanced insulation materials to withstand high stress and environmental factors. -
What are the differences between high, medium, and low voltage power cables?
The main difference between high, medium, and low voltage power cables lies in the voltage level and their intended applications. High-voltage cables are used for long-distance power transmission, typically ranging from 1kV to 765kV. Medium voltage cables (1kV to 35kV) are used for power distribution from substations to local areas. Low-voltage cables (up to 1kV) are used in residential, commercial, and industrial buildings for everyday power supply. -
What is the application of low voltage power cables?
Low-voltage power cables are used in residential, commercial, and industrial electrical wiring systems. These cables provide power for lighting, appliances, and smaller equipment within homes, office buildings, and factories. Low-voltage cables are commonly used for internal wiring, electrical circuits, and power distribution within the building. They are designed to carry power safely and efficiently at voltages up to 1kV. -
How are medium voltage power cables used in power distribution?
Medium voltage power cables (1kV to 35kV) are used in power distribution systems to carry electricity from substations to residential neighborhoods, commercial buildings, and industrial complexes. These cables are designed to handle higher loads than low-voltage cables, and they are ideal for situations where energy needs are larger but not as high as transmission-level power. Medium voltage cables provide stable and reliable electrical service to a wide range of users. -
What materials are commonly used in power cables for high, medium, and low voltage systems?
Power cables for high, medium, and low voltage systems are typically made with copper or aluminum conductors for excellent electrical conductivity. The insulation materials include cross-linked polyethylene (XLPE) for high performance and thermoplastic compounds like PVC for standard applications. Sheath layers are typically made of PVC or PE for mechanical protection and weather resistance. The materials are selected based on the voltage rating and the specific environmental and performance requirements of the cable.