75kVA Dry Type Transformer | High Efficiency Indoor Power Transformer
The 75kVA Dry Type Transformer is a compact, three-phase, high-efficiency indoor power transformer engineered for safe, reliable voltage transformation in commercial, institutional, and light industrial environments. Utilizing advanced cast-resin or vacuum pressure impregnated (VPI) insulation technology, it eliminates oil-related fire hazards, maintenance requirements, and environmental risks while delivering exceptional performance in confined spaces, high-rise buildings, hospitals, schools, data centers, office complexes, and renewable energy tie-in applications.
125kVA Cast Resin Dry Type Transformer 3 Phase 10kV/0.4kV Copper Winding IEC Certified
The 125kVA Cast Resin Dry Type Transformer is a compact, three-phase, high-efficiency indoor power transformer engineered for safe and reliable voltage transformation in commercial, institutional, and light-to-medium industrial environments. Featuring advanced cast-resin encapsulation and full copper windings, it eliminates oil-related fire hazards, environmental risks, and routine maintenance while delivering superior performance in confined spaces, high-rise buildings, hospitals, schools, data centers, office complexes, and renewable energy tie-in applications. Fully compliant with IEC 60076-11, IEC 60076-1, IEC 60076-3, IEC 60076-5, IEC 60076-20, IEEE C57.12.01, IEEE C57.12.91, UL 1561 (optional), and DOE 2016 efficiency standards.
160 kVA Three Phase Cast Resin Dry Type Transformer Low Loss Energy Efficient
The 160 kVA Three Phase Cast Resin Dry Type Transformer Low Loss Energy Efficient is a state-of-the-art, maintenance-free power solution engineered for indoor installations where safety, reliability, and sustainability are paramount. Encased in high-quality epoxy resin under vacuum pressure, its windings deliver outstanding moisture resistance, superior partial discharge performance, and fire-retardant self-extinguishing properties without flammable liquids. Utilizing premium grain-oriented silicon steel cores and optimized conductor designs, this transformer achieves significantly reduced no-load and load losses, attaining high efficiency levels often exceeding 98.5% and complying with stringent energy regulations. With natural air (AN) cooling, low acoustic emissions below typical 58-62 dB, and Class F or H insulation, it ensures stable operation in harsh indoor environments. Fully compliant with IEC 60076-11, this compact, eco-conscious dry-type unit supports primary voltages like 10kV/11kV/20kV/35kV stepping down to 0.4kV or custom secondaries, making it ideal for modern, green power distribution networks.
250kVA Dry Type Cast Resin Transformer 10kV/0.4kV Copper Core | CE/IEC/UL
Introducing the premium 250kVA Dry Type Cast Resin Transformer 10kV/0.4kV Copper Core, a high-performance, maintenance-free solution engineered for safe and efficient indoor power distribution. Featuring fully vacuum-cast epoxy resin windings with premium copper conductors, this three-phase transformer delivers exceptional low-loss performance, reduced no-load and load losses, and outstanding energy efficiency often surpassing 98%. The cast resin encapsulation provides superior moisture resistance, fire self-extinguishing properties, and high partial discharge immunity, eliminating risks associated with oil-filled units. With natural air (AN) cooling, low noise levels, Class F/H insulation, and robust short-circuit withstand capability, it ensures reliable operation in demanding environments. Certified to CE, IEC 60076-11, and UL equivalents where applicable, this compact dry-type transformer supports primary 10kV (with ±2×2.5% off-circuit taps) to secondary 0.4kV transformation, ideal for modern sustainable electrical infrastructures prioritizing safety, energy savings, and environmental compliance.
315kVA Dry Type Transformer
The 315 kVA Cast Resin Dry Type Distribution Transformer 480V-208Y/120V, a robust, maintenance-free solution optimized for safe indoor power conversion in North American electrical systems. This three-phase dry-type transformer features premium copper windings fully encapsulated in high-grade epoxy resin under vacuum pressure, delivering exceptional moisture resistance, fire self-extinguishing performance (F1 class), and minimal partial discharge for long-term reliability. With premium low-loss grain-oriented silicon steel cores and natural air (AN) cooling, it achieves superior energy efficiency exceeding DOE 2016 minimums, often reaching 98%+ under typical loads, while maintaining low noise levels and Class F/H insulation for demanding environments. Compliant with IEC 60076-11, ANSI/IEEE C57.12.01, UL, and DOE standards, this compact unit steps down 480V Delta primary (with ±2×2.5% off-circuit taps) to 208Y/120V secondary, providing stable power for commercial, industrial, and institutional applications with zero oil hazards and eco-friendly operation.
350kVA Epoxy Resin Cast Dry Type Transformer 3 Phase 6.6kV/0.4kV Low Noise
Presenting the high-performance 350kVA Epoxy Resin Cast Dry Type Transformer 3 Phase 6.6kV/0.4kV Low Noise, a cutting-edge, eco-friendly power distribution solution ideal for indoor applications demanding superior safety and quiet operation. This three-phase dry-type transformer utilizes premium epoxy resin vacuum casting on high-conductivity copper windings and low-loss grain-oriented silicon steel cores, achieving outstanding energy efficiency (typically 98%+), minimal no-load/load losses, and exceptional partial discharge suppression (<10pC). With natural air (AN) cooling, Class F/H insulation, fire-retardant self-extinguishing properties, and robust short-circuit withstand, it offers maintenance-free reliability in harsh or sensitive environments. Fully compliant with IEC 60076-11, this compact unit steps down 6.6kV primary (with ±2×2.5% off-circuit taps) to 0.4kV secondary (Dyn11 vector group), supporting sustainable grids with overload capability and zero oil risks.
3150kVA Three Phase Dry Type Power Transformer Custom Voltage Factory Direct
The 3150kVA Three Phase Dry Type Power Transformer Cast Resin Custom Voltage Factory Direct is a large-capacity, high-efficiency cast-resin dry-type power transformer designed for demanding indoor and semi-outdoor applications in heavy commercial, industrial, data center, renewable energy, mining, railway, and large-scale EV infrastructure projects. Fully compliant with IEC 60076-11, IEC 60076-1/2/3/5/20, EN 50588-1 (eco-design), IEEE C57.12.01, IEEE C57.12.91, UL 1561 (optional), and DOE 2016 efficiency standards, this 3150 kVA dry-type transformer achieves superior energy efficiency (typically 99.35–99.55% at full load), ultra-low no-load and load losses, strong overload capability (up to 150% short-term), low sound levels (<65 dB standard; <60 dB low-noise execution), and a design life exceeding 40 years.
11/0.4kV Dry Type Transformer | Indoor Power Transformer
Discover the reliable 11/0.4kV Dry Type Transformer | Indoor Power Transformer, a safe, oil-free solution designed for efficient medium-to-low voltage conversion in indoor electrical installations. This three-phase dry-type transformer (typically cast resin or vacuum pressure impregnated) features premium low-loss silicon steel cores and high-conductivity copper windings, achieving superior energy efficiency often exceeding 98% and complying with IEC 60076-11 standards. The epoxy resin encapsulation provides excellent moisture resistance, fire self-extinguishing properties (F1 class), minimal partial discharge (<10pC), and robust short-circuit withstand capability. With natural air (AN) cooling and optional forced air (AF) upgrades, it offers low noise operation, Class F/H insulation, and maintenance-free performance in demanding environments. Ideal for step-down from 11kV primary (with ±2×2.5% or wider off-circuit taps) to 0.4kV secondary (Dyn11 vector group standard), this indoor power transformer supports capacities from 100kVA to several MVA, delivering stable, eco-friendly power distribution without oil-related risks.
10kV Cast Resin Dry Type Transformer Copper Winding
The 10kV Cast Resin Dry Type Transformer Copper Winding, a high-reliability, oil-free power solution engineered for safe and efficient indoor medium-voltage distribution. This three-phase dry-type transformer features fully vacuum-cast epoxy resin encapsulation around high-purity copper windings, combined with premium low-loss grain-oriented silicon steel cores to deliver exceptional energy efficiency (typically 98%+), significantly reduced no-load and load losses, and outstanding partial discharge performance (<10pC). The cast resin design ensures superior moisture resistance, self-extinguishing fire safety (F1 class), robust short-circuit withstand, and maintenance-free operation. Natural air (AN) cooling with optional forced air (AF) upgrades supports high overload capacity while maintaining low acoustic emissions through advanced vibration isolation and optimized core/winding geometry. Compliant with IEC 60076-11 and equivalent standards, this transformer steps down 10kV primary (with ±2×2.5% or wider off-circuit taps) to 0.4kV secondary (Dyn11 vector group standard), making it the ideal choice for modern commercial, industrial, and utility indoor installations prioritizing safety, sustainability, and long-term performance.In-Depth Analysis
Comparative Analysis of Efficiency and Loss
Compared to the industry average, transformers exhibit lower losses and higher efficiency across the entire load range.
Load Efficiency Comparison(%)
No-load Loss Comparison(W)
High-efficiency Core Design
High magnetic permeability and low loss silicon steel sheets are used and processed by special process to reduce hysteresis loss and eddy current loss and improve conversion efficiency.
Multiple Protection Systems
IP65 protection grade design combines multiple protection measures such as anti-corrosion, anti-UV, anti-condensation and anti-small animal intrusion.
Ultra-low Noise Technology
A special shock-absorbing structure, low-noise fans, and optimized heat dissipation design ensure operating noise is far below industry standards.
Intelligent Cooling System
The heat dissipation system with adaptive temperature control automatically adjusts the heat dissipation efficiency according to the load and ambient temperature to reduce energy consumption.
Safety Wiring System
Insulated protective cover and anti-misoperation design ensure personnel safety during installation and maintenance and reduce accident risks
Intelligent Monitoring
An optional remote monitoring system is available to monitor operating status, temperature, load and other parameters in real time, and supports fault warning and remote diagnosis.
Environmental Adaptability Analysis
Dry type transformers have been rigorously tested and can operate stably under various harsh environmental conditions.
Temperature Range
-40℃ ~ +55℃
Can work normally in extreme high and low temperature environments
Humidity Adaptation
0 ~ 100% RH
Including condensation environment, no frost requirement
Seismic Resistance Level
IEC 60068-2-57
Suitable for earthquake-prone areas
Altitude
≤3000m
More than special design
Why Choose Us
Dry Type Transformers Manufacturer
Dry Type Transformers Types
High Efficiency & Reliable Performance
Versatile Applications & Global Standards
Product Show
Testing and Certification
Bare Cable Test Report
SGS Inspection Report
Certificate of Acceptance
ISO Quality Certificate
ISO Environmental Certificate
ISO Occupational Certificate
UL Laboratory Certificate
UL Product Certificate
Project Cases
Venezuela Residential Area
CompletedProvide stable and reliable power conversion solutions for the residential area to meet diverse production needs.
Country:Venezuela
Model:75kVA Dry Type Transformer x 20
Rwanda Data Center
CompletedEnsure the power safety of surrounding residents and meet daily work needs
Country:Rwanda
Model:167kVA Dry Type Transformer x 15
Panama Factory
CompletedNPC transformers provide safe, efficient, and reliable power distribution in Panama.
Country:Panama
Model:150kVA Dry Type Transformer x 30
Related Articles
Technical Advantages
FAQ From Customers
-
What is a dry type transformer?
A dry type transformer is an electrical transformer that uses air or resin for cooling instead of insulating oil. The most common designs are cast resin dry type transformers (CRT) and vacuum pressure impregnated (VPI) types. These transformers are ideal for indoor installations where safety and environmental protection are essential.
Dry type distribution transformers are widely used in commercial buildings, hospitals, tunnels, and renewable energy systems because they offer high efficiency, low noise, and minimal maintenance. -
Why would you use a dry transformer?
Dry type transformers are preferred in environments where fire safety, reliability, and low maintenance are critical. Since they don’t use oil, there’s no risk of leakage or fire, making them ideal for indoor transformer installations. They’re also environmentally friendly and resistant to moisture and contaminants. Industries such as data centers, offices, and hospitals choose cast resin dry type transformers for their excellent insulation performance, compact design, and long service life. -
What is the difference between dry type and oil type transformer?
The key difference lies in the cooling and insulation method. Dry type transformers use air or epoxy resin for cooling, while oil type transformers (also known as oil immersed transformers) use insulating oil to dissipate heat. Dry type transformers are safer and cleaner, ideal for indoor use, while oil immersed transformers are typically used outdoors for higher-capacity networks. Both provide efficient power distribution, but the dry type transformer is preferred in fire-sensitive or environmentally restricted areas. -
Can dry type transformers be used outside?
Yes, dry type transformers can be used outdoors if they are properly enclosed and protected from weather conditions. NPC Electric offers outdoor dry type transformers with IP-rated enclosures, corrosion-resistant coatings, and enhanced ventilation systems. These transformers maintain excellent performance in harsh or humid climates. Whether used as a dry type distribution transformer or three phase dry type transformer, they provide reliable operation with minimal maintenance for outdoor electrical networks. -
What are the requirements for a dry type transformer?
The main requirements for a dry type transformer include proper ventilation, insulation class, protection rating, and installation clearance. Dry type transformers should comply with international standards such as IEC 60076, IEEE C57.12, and ANSI for safety and efficiency. They must be installed in well-ventilated areas with adequate cooling and protection from dust or moisture. NPC Electric’s cast resin dry type transformers are manufactured to meet these requirements, ensuring long-term reliability and consistent power performance in demanding applications.