Wires and Cables
Service Drop Cable(ANS/CEA S-76-474)
3/0 Aega Aluminum Conductor Triplex Overhead Service Drop Cable
The 3/0 Aega Aluminum Triplex Overhead Service Drop Cable is engineered for overhead utility service applications, delivering power from pole-mounted transformers to service entrances in residential, commercial, or light industrial environments. This cable is constructed with two insulated aluminum phase conductors and a bare ACSR (Aluminum Conductor Steel Reinforced) neutral messenger that provides mechanical support as well as grounding. Each phase conductor is insulated with black cross-linked polyethylene (XLPE) for enhanced resistance to weather, heat, and environmental wear.
3/0 Fulgar Aluminum Conductor Triplex Overhead Service Drop Cable
The 3/0 Fulgar Aluminum Triplex Overhead Service Drop Cable is specifically designed for overhead utility applications. It consists of two insulated aluminum phase conductors and a bare AAAC (All-Aluminum Alloy Conductor) neutral messenger, forming a reliable and lightweight triplex configuration ideal for aerial installations. The cable is typically used to transmit power from pole-mounted distribution transformers to service entrances in residential, commercial, or light industrial settings. The phase conductors are insulated with black cross-linked polyethylene (XLPE), offering superior weather resistance, mechanical strength, and thermal stability.
3/0 Cherrystone Aluminum Conductor Triplex Overhead Service Cable
The 3/0 Cherrystone Triplex Aluminum Conductor Overhead Service Drop Cable is engineered for aerial power distribution applications. Designed with two insulated phase aluminum conductors and a bare ACSR (Aluminum Conductor Steel Reinforced) neutral messenger, it is ideal for delivering power from utility poles to residential and commercial service entrances. This cable supports up to 600 volts phase-to-phase, and is suitable for both polyethylene and XLPE (cross-linked polyethylene) insulation, offering reliable thermal and mechanical performance in harsh outdoor environments.
3/0 Flustra Aluminum Conductor Triplex Overhead Service Drop Cable
The 3/0 Flustra Triplex Aluminum Overhead Service Drop Cable is a highly durable, weather-resistant cable designed for power distribution from utility poles to residential or light commercial buildings. This triplex cable includes two phase conductors and one bare neutral messenger, typically made of AAAC (All-Aluminum Alloy Conductor), providing both support and a current return path. With a voltage rating of 600V phase-to-phase and XLPE (Cross-Linked Polyethylene) insulation, this cable is built for high performance and reliability in aerial applications.
3/0 Melita Aluminum Conductor Triplex Overhead Service Drop Cable
The 3/0 Melita Aluminum Triplex Overhead Service Drop Cable is a robust aerial cable solution designed for overhead power delivery from pole-mounted transformers to residential or commercial weather heads. Featuring two-phase conductors and one bare AAC (All-Aluminum Conductor) neutral messenger, this triplex cable ensures reliable low-voltage distribution. Each conductor is insulated with UV-resistant black cross-linked polyethylene (XLPE) for added safety and durability in outdoor environments. Built to meet ASTM and ICEA standards, the Melita cable offers a trusted solution for utility and service entrance applications.
3/0 Mursia Aluminum Conductor Triplex Overhead Service Drop Cable
The 3/0 Mursia Triplex Aluminum Overhead Service Drop Cable is a premium-grade aerial electrical cable engineered for utility-to-premises power distribution. Designed with two insulated phase conductors and one bare ACSR (Aluminum Conductor Steel Reinforced) neutral messenger, the Mursia cable ensures strength, conductivity, and stability during aerial installation. This triplex cable is suitable for applications rated at 600 volts or less, with a maximum conductor temperature of 90°C when using XLPE insulation. Mursia cables are weather-resistant, durable, and manufactured in compliance with ASTM and ICEA industry standards.
4/0 Arca Aluminum Conductor Triplex Overhead Service Drop Cable
The 4/0 Arca Aluminum Triplex Overhead Service Drop Cable is designed for overhead power distribution from utility lines to residential or commercial buildings. It consists of two phase conductors and one neutral messenger conductor. Built for outdoor installations through the weather head at voltages up to 600V, this cable is ideal for overhead service drop applications. The phase conductors are insulated with black cross-linked polyethylene (XLP) for superior durability and weather resistance. The neutral conductor is a bare AAAC (All-Aluminum Alloy Conductor), providing both mechanical support and electrical grounding.
4/0 Cerapus Aluminum Conductor Triplex Overhead Service Drop Cable
The 4/0 Cerapus Aluminum Triplex Overhead Service Drop Cable is engineered for reliable overhead power distribution from utility poles to residential or commercial buildings. It includes two phase conductors and one neutral messenger, designed for use in 600V systems, typically routed through weather heads for secure service drops. The phase conductors are insulated with black cross-linked polyethylene (XLP) to ensure excellent weather resistance, while the neutral conductor consists of bare ACSR (Aluminum Conductor Steel Reinforced) wire, providing both tensile strength and conductivity.
4/0 Lepas Aluminum Conductor Triplex Overhead Service Drop Cable
4/0 Lepas Triplex Aluminum Overhead Service Drop Cable is specifically engineered to supply power from a pole-mounted transformer to a consumer’s service entrance, typically through a weather head connection. With its robust construction and weather-resistant materials, it's an ideal solution for outdoor utility and residential power delivery. This triplex assembly consists of two phase conductors and one bare neutral messenger (AAAC – All-Aluminum Alloy Conductor), providing excellent strength-to-weight ratio and corrosion resistance. The phase conductors are insulated with black cross-linked polyethylene (XLP) for enhanced thermal and environmental performance.In-Depth Analysis
Comparative Analysis of Efficiency and Loss
Compared to the industry average, NPC Overhead Insulated Cable exhibit lower losses and higher efficiency across the entire load range.
Load Efficiency Comparison(%)
No-load Loss Comparison(W)
High Conductivity Design
High-purity oxygen-free copper or high-quality aluminum conductors are used with smooth surface and low resistance to ensure efficient power transmission and reduce energy loss.
Insulation Protection System
Use flame-retardant, wear-resistant and corrosion-resistant polymer insulation materials to meet the safe operation requirements in different environments.
Weather-Resistant & Durable Technology
The outer sheath is made of UV-resistant, heat-resistant, and oil-resistant materials, making it suitable for high and low temperatures, humidity, and long-term outdoor use.
Safe Flame Retardant System
The multi-layered flame-retardant structure effectively slows the spread of flames and releases low-smoke, halogen-free gases during combustion, reducing secondary hazards.
Easy Installation & Maintenance
The flexible core and flex-resistant outer sheath provide a small bend radius and high installation efficiency. Color coding and length markings reduce installation and maintenance costs.
Intelligent Monitoring
An optional remote monitoring system is available to monitor operating status, temperature, load and other parameters in real time, and supports fault warning and remote diagnosis.
Environmental Adaptability Analysis
NPC Service Drop Cable have been rigorously tested and can operate stably under various harsh environmental conditions.
Temperature Range
-40℃ ~ +55℃
Can work normally in extreme high and low temperature environments
Humidity Adaptation
0 ~ 100% RH
Including condensation environment, no frost requirement
Weather Resistance Grade
UV/IEC 60811-501
The outer sheath has excellent UV resistance and aging resistance
Chemical Corrosion Resistance
Oil / Acid / Alkali
Resistant to oil, acid, alkali and some chemical corrosion environments
Why Choose Us
Overhead Insulated Cable Manufacturer
Overhead Insulated Cable Benefits
Overhead Insulated Cable Installation
Testing and Certification
Product Show
Testing and Certification
Bare Cable Test Report
SGS Inspection Report
Certificate of Acceptance
ISO Quality Certificate
ISO Environmental Certificate
ISO Occupational Certificate
UL Laboratory Certificate
UL Product Certificate
Project Cases
Peru Solar PV Project
CompletedNPC Electric Delivers Medium-Voltage Cables for Peru Solar PV Project
Country:Peru
Model:HEPRZ1(AS) 1x630 mm² 19/33kV x 6km
Chile El Project
CompletedReliable 19/33kV MV cables ensuring safe, stable, and efficient power transmission for critical projects.
Country:Chile
Model:19/33kV MV Power Cables x 5km
Dominican Edenorte Project
CompletedProvide outdoor power solutions for urban main road reconstruction projects to adapt to complex environments.
Country:Dominican
Model:NPC AAAC Cable & Triplex Cable x 10km
Technical Advantages
FAQ From Customers
-
What is a service drop cable?
A service drop cable is an electrical cable that connects overhead power lines from the utility's distribution system to a residential or commercial building’s main electrical panel. Typically made of aluminum or copper, the cable serves as the final connection between the utility provider and the consumer, delivering electricity safely and reliably. It is often used for low-voltage power distribution to homes and businesses. -
What is a drop cable used for?
A drop cable is used to connect electrical service lines from a utility pole or transformer to the customer’s property. It provides the final connection for residential or commercial electrical service. Drop cables can be overhead service drop cables or underground service cables, depending on the installation method. These cables ensure safe and efficient delivery of electricity from the electricity distribution network to the meter and main breaker panel of a building. -
What type of wire is used for a service drop?
The type of wire used for a service drop depends on the voltage and installation method. Commonly, aluminum conductors are used in overhead service drop cables because of their lightweight and high conductivity. Duplex, triplex, and quadruplex cables are typically used, with triplex cables often being the most common for three-phase systems. These wires are designed to withstand environmental stress and provide safe power distribution for residential connections. -
What is an overhead service drop cable?
An overhead service drop cable is a type of drop cable that connects the utility pole to the house or building through overhead power lines. This cable is usually aluminum or copper and is designed to carry low voltage electricity from the distribution network to the customer's property. Overhead service drop cables are commonly used in residential areas and can be subjected to weather and environmental challenges, so they are built with durable, weather-resistant materials. -
What is the difference between Duplex, Triplex, and Quadruplex service drop cables?
Duplex, triplex, and quadruplex service drop cables differ in their construction and use:
1. A duplex cable consists of two wires and is typically used for single-phase connections in residential service drops.
2. Triplex cable includes three conductors and is used for three-phase connections, commonly in larger residential or commercial installations.
3. Quadruplex cable includes four wires and is used for three-phase service with an additional neutral conductor. This makes it ideal for larger, more complex service drops and higher voltage applications. Each cable type provides reliable electrical service and safe connections between the utility and the building.