AAAC Conductor and Triplex Cables for Edenorte Project in the Dominican Republic
The AAAC Conductor and Triplex Cables produced by NPC have passed strict quality inspection by engineers and will be sent to the Dominican Republic in the near future.

NPC Electric is proud to announce the successful supply of AAAC 2/0 conductor and various Triplex cables to support the Edenorte project in the Dominican Republic. This achievement highlights our ongoing commitment to providing high-quality electrical solutions for utility companies across Latin America.
For this project, we supplied the following products:
AAAC 2/0 Conductor
Alambre Triplex #06
Alambre Triplex #02
Alambre Triplex #04
Alambre Triplex 1/0 AWG
Alambre Triplex 2/0 AWG
Our AAAC (All Aluminum Alloy Conductor) is known for its excellent conductivity, corrosion resistance, and lightweight performance — ideal for overhead power distribution. The Triplex service drop cables were customized to meet Edenorte’s technical specifications and were rigorously tested for durability and efficiency in tropical environments. We offer comprehensive low voltage cable solutions to help you achieve engineering success.
This supply is another milestone in our growing presence in the Caribbean market. With reliable logistics, strict quality control, and responsive customer service, NPC Electric continues to support major infrastructure projects across the region.
Related Articles
Related Products
Steel Tape Armoured Cable Type
The Steel Tape Armoured Cable (STA Cable) is designed for reliable power transmission in environments requiring enhanced mechanical protection. Manufactured with high-quality copper or aluminum conductors, XLPE insulation, galvanized steel tape armour, and a durable PVC outer sheath, the cable provides exceptional durability and long-term operational reliability. The galvanized steel tape armour offers superior resistance against mechanical impact, compression, and external damage, making the cable suitable for underground installations and harsh industrial environments. The XLPE insulation ensures excellent electrical performance, low dielectric losses, and continuous operating temperatures up to 90°C. The PVC sheath protects the cable against moisture, chemicals, abrasion, and environmental exposure, extending service life and reducing maintenance requirements. Manufactured according to IEC 60502-1 and other international standards, the cable is widely used in power distribution networks, industrial facilities, infrastructure projects, renewable energy installations, and utility systems. The Steel Tape Armoured Cable combines electrical efficiency, mechanical strength, and installation flexibility, making it a dependable solution for demanding power distribution applications.
250kVA Single Phase Pad Mounted Transformer
NPC ELECTRIC 250 kVA single phase pad mounted transformer operates safely, reliably, and efficiently and can be installed indoors and outdoors. The industrial transformer has a rated power of 250 kVA, a primary voltage of 27600/16000V single-phase and a secondary voltage of 120/240V single-phase.The transformer has a primary loop feed and dead front primary connections.
25kV 3-Layer AAAC/ACSR/AAC Tree Wire - Triple Layer Covered MV Conductor
The 3-Layer 25kV AAAC/ACSR/AAC Tree Wire is a specialized covered medium-voltage overhead conductor developed for distribution lines in areas with dense vegetation. It uses concentrically stranded AAAC, ACSR, or AAC conductors protected by a triple-layer system of track-resistant HDPE or XLPE. The multi-layer covering delivers exceptional tracking resistance, abrasion protection, and weatherability while greatly reducing the risk of electrical faults from tree limb contact and helping minimize wildfire ignition potential. This advanced design allows closer spacing to vegetation and lowers vegetation management costs. Suitable for conventional overhead or spacer cable systems, the 3-Layer 25kV AAAC/ACSR/AAC Tree Wire offers a cost-effective solution for improving line reliability. It complies with ICEA and ASTM standards and undergoes extensive quality testing to ensure long-term performance and safety.
1000kVA Dry Type Transformer
NPC ELECTRIC 1000kVA Dry-Type Transformer offers efficient, oil-free power distribution with a compact design. Equipped with advanced insulation and cooling systems, it ensures safe and reliable operation with minimal maintenance. Ideal for industrial and commercial applications, it provides environmentally friendly and cost-effective performance. Standard features include three-phase configuration, primary voltages 208V–600V (e.g., 480V Delta, 600V Delta), secondary voltages such as 208Y/120V, 480Y/277V, or custom, aluminum or copper windings, 150°C rise (standard) or 115°C/80°C with 220°C insulation class, ±2×2.5% primary taps, NEMA 1 ventilated enclosure (NEMA 3R/encapsulated options), natural convection cooling (AN), electrostatic shielding, and NEMA-compliant low sound levels.
NTSCGEWOU 3.6/6kV, 6/10kV, 8.7/15kV, 12/20kV Cable
The NTSCGEWOU 3.6/6kV, 6/10kV, 8.7/15kV, 12/20kV Cable is a high-performance flexible medium-voltage trailing/reeling cable engineered for extreme mining and tunneling conditions. It comprises class 5 finely stranded tinned copper phase conductors for superior flexibility and corrosion resistance, semi-conductive conductor and insulation screens for field control, EPR insulation for excellent dielectric strength and 90°C continuous operation, copper wire braid screen for EMI protection and grounding, control conductors, monitoring conductor (ÜL), and a durable rubber outer sheath resistant to oil, flame, abrasion, tearing, and mechanical stress. Compliant with DIN VDE 0250, it handles high tensile loads, fast reeling speeds, tight bending radii, and effective EMC shielding across all voltage levels. The NTSCGEWOU delivers safe, reliable MV power to mobile equipment such as shearers, tunnel boring machines, draglines, and conveyors in harsh underground and opencast environments, minimizing downtime and ensuring long-term operational efficiency.
6kV Three-Phase Oil-Immersed Power Transformer
The 6kV Three-Phase Oil-Immersed Power Transformer is designed for stable and efficient voltage conversion in industrial and commercial power distribution systems. With a durable oil-immersed insulation structure and high-quality copper windings, it offers excellent thermal performance, strong dielectric strength, and reliable operation under varying load conditions. Its compact design, robust core materials, and advanced cooling system ensure low losses, reduced noise, and long service life. This 6kV transformer is suitable for factories, mining sites, distribution stations, and utility networks requiring consistent and safe electrical power supply. Engineered to meet international standards, it provides dependable performance and high efficiency across diverse low-to-medium voltage applications.
10kVA Single Phase Pad Mounted Transformer
The 10 kVA pad-mounted transformer meets ANSI, CSA, NEMA, IEEE, and DOE standards. NPC Electric's 10 kVA pad-mounted transformers comply with DOE efficiency values and are UL listed. Based on specific technical requirements, the incoming line can be designed as either a loop feed or radial feed, and it also supports customized dual voltage.
GREELEY AAAC Conductor Cable
GREELEY AAAC (All Aluminum Alloy Conductor) cables are manufactured in accordance with ASTM B399 standards, offering a balance of strength, conductivity, and corrosion resistance. With 850 mm² nominal area and 61-strand construction, it features heat-treated aluminum-magnesium-silicon alloy (6201-T81) for enhanced strength (295 MPa min) and conductivity (53% IACS min). Meeting ASTM B398, B399, IEC 61089, and BS EN 50182 standards, this cable supports ampacity up to 1250A at 75°C and voltages up to 33kV. The uniform alloy eliminates bimetallic issues, offering superior corrosion resistance in harsh environments compared to ACSR. Low weight reduces sag and installation costs, enabling longer spans. The Greeley AAAC Conductor Cable provides minimal electrical losses, high mechanical endurance, and excellent weather tolerance. Flame-retardant options available. Suited for urban grids, renewable connections, and coastal installations, it ensures cost-effective, maintenance-free power delivery in overhead systems globally, outperforming traditional conductors in reliability and lifespan.
1272 MCM Narcissus AAC All Aluminum Bare Conductor Cable
The 1272 MCM Narcissus AAC Cable represents premium All Aluminum Conductor technology for overhead power applications. Built with 61 strands of high-conductivity 1350-H19 aluminum, this bare conductor delivers an optimal balance of electrical efficiency and mechanical robustness. With a 1.300-inch diameter, 22,300 lbs breaking strength, and 1140 amps ampacity, the Narcissus AAC offers low DC resistance of 0.0135 ohms per 1000 ft at 20°C and a weight of 1194.8 lbs per 1000 ft. This design minimizes sag while providing excellent corrosion resistance for extended outdoor service. Manufactured to meet ASTM B-230 and B-231 standards, the 1272 MCM Narcissus AAC Cable undergoes extensive quality testing from raw materials through finished product. It is the ideal solution for new installations and upgrades in transmission and distribution systems that demand lightweight, high-conductivity bare aluminum conductors.
Control Cable 0.6/1 kV CVV-SWA to IEC 60502 Standard (2-16 core)
NPC Electric Control Cable 0.6/1 kV CVV-SWA to IEC 60502 Standard (2-16 core) is built for maximum protection in demanding control applications. It features concentric stranded copper conductors for excellent conductivity and flexibility, insulated with high-grade black PVC and identified by white numbers. A copper tape shield minimizes electromagnetic interference, while the steel wire armour (SWA) provides superior mechanical protection against impacts, rodents, and crushing. Dual PVC sheaths enhance flame retardancy and resistance to moisture and chemicals. Rated for voltages up to 1 kV, it operates reliably from -15°C to 70°C. Compliant with IEC 60502, this cable is suited for supervisory circuits, power stations, and installations in ducts, trays, underground, or direct burial. With 2 to 16 cores, it handles complex control setups, ensuring signal integrity and reducing downtime. Ideal for industrial environments requiring robust defence, the CVV-SWA delivers long-term durability, cost efficiency, and safety through advanced engineering and quality materials.
500 MCM Zinnia AAC Cable
The 500 MCM Zinnia AAC Cable represents premium All Aluminum Conductor technology for overhead power applications. Built with 19 strands of high-conductivity 1350-H19 aluminum, this bare conductor delivers an optimal balance of electrical efficiency and mechanical robustness. With a 0.811-inch diameter, 8,760 lbs breaking strength, and 658 amps ampacity, the Zinnia AAC offers low DC resistance of 0.0346 ohms per 1000 ft at 20°C and a weight of 469.4 lbs per 1000 ft. This design minimizes sag while providing excellent corrosion resistance for extended outdoor service. Manufactured to meet ASTM B-230 and B-231 standards, the 500 MCM Zinnia AAC Cable undergoes extensive quality testing from raw materials through finished product. It is the ideal solution for new installations and upgrades in transmission and distribution systems that demand lightweight, high-conductivity bare aluminum conductors.
6 Patella Aluminum Conductor Triplex Overhead Service Drop Cable
The 6 Patella Aluminum Conductor Triplex Overhead Service Drop Cable is designed to provide reliable overhead power distribution from utility lines to service entrances. The cable structure includes two insulated aluminum phase conductors twisted around a high-strength neutral messenger, ensuring stable electrical transmission and excellent mechanical support. Manufactured using high-purity aluminum and durable, weather-resistant insulation materials, the 6 Patella Aluminum Conductor Triplex Overhead Service Drop Cable offers low weight, easy handling, and reduced installation effort. The insulation system is engineered to resist UV radiation, moisture, temperature variation, and environmental aging, ensuring long-term outdoor performance. A comprehensive quality assurance system is applied throughout the manufacturing process. The 6 Patella Aluminum Conductor Triplex Overhead Service Drop Cable undergoes strict raw material testing, continuous process inspection, and rigorous finished product testing. Each production stage follows standardized procedures in accordance with international standards and utility requirements, making this cable a dependable solution for residential, commercial, and light industrial overhead service drop applications.
2/0 Nassa Aluminum Conductor Triplex Overhead Service Drop Cable
The 2/0 Nassa Aluminum Conductor Triplex Overhead Service Drop Cable is designed for reliable overhead electrical service connections between utility distribution lines and end users. The cable structure includes two insulated aluminum phase conductors twisted around a bare aluminum neutral messenger, providing excellent electrical performance and mechanical strength. Manufactured with high-purity aluminum and durable, weather-resistant insulation, the 2/0 Nassa Aluminum Conductor Triplex Overhead Service Drop Cable offers low electrical resistance, corrosion resistance, and long-term stability in outdoor environments. Its lightweight design allows for efficient installation while maintaining the tensile strength required for aerial applications. The cable is engineered to perform under UV exposure, wind load, and temperature variations. Comprehensive quality control and systematic testing are applied throughout production to ensure compliance with industry standards and dependable service performance.
1590 MCM LAPWING ACSR Conductor Cable
The ACSR 1590 MCM Lapwing 45/7 is a high-efficiency, bare concentric-lay-stranded conductor designed for superior performance in overhead power transmission and distribution systems, meeting ASTM B232 standards. It features a galvanized steel core (Class A or B) with 7 steel strands for robust mechanical strength, surrounded by 45 strands of hard-drawn 1350-H19 aluminum wire for excellent electrical conductivity. Ideal for long-span transmission lines and primary/secondary distribution networks, the Lapwing configuration offers exceptional corrosion resistance and customizable aluminum-to-steel ratios to fulfill specific electrical and mechanical demands, ensuring reliable and durable power delivery. Galvanized steel wires used for the core undergo tensile testing, zinc coating thickness measurement, and corrosion resistance evaluation. Dimensional accuracy and surface condition of all materials are verified before approval.