NPC Electric is proud to announce the successful supply of AAAC 2/0 conductor and various Triplex cables to support the Edenorte project in the Dominican Republic. This achievement highlights our ongoing commitment to providing high-quality electrical solutions for utility companies across Latin America.
For this project, we supplied the following products:
AAAC 2/0 Conductor
Alambre Triplex #06
Alambre Triplex #02
Alambre Triplex #04
Alambre Triplex 1/0 AWG
Alambre Triplex 2/0 AWG
Our AAAC (All Aluminum Alloy Conductor) is known for its excellent conductivity, corrosion resistance, and lightweight performance — ideal for overhead power distribution. The Triplex service drop cables were customized to meet Edenorte’s technical specifications and were rigorously tested for durability and efficiency in tropical environments. We offer comprehensive low voltage cable solutions to help you achieve engineering success.
This supply is another milestone in our growing presence in the Caribbean market. With reliable logistics, strict quality control, and responsive customer service, NPC Electric continues to support major infrastructure projects across the region.
Related Articles
Related Products
65kV Three-Phase Oil-Immersed Power Transformer with No-Load Voltage Regulation
The 65kV Three-Phase Oil-Immersed Power Transformer with No-Load Voltage Regulation is engineered for medium-to-high voltage distribution systems requiring stable performance and precise voltage control. Equipped with a no-load tap changer, the transformer allows flexible adjustment of voltage ratios to meet varying grid demands. Its high-grade silicon steel core and oxygen-free copper windings ensure low losses, superior thermal efficiency, and long operational life. The oil-immersed cooling system provides enhanced heat dissipation, while the durable outdoor-rated tank structure enables reliable operation in harsh climatic environments. Designed in compliance with IEC, IEEE, and GB standards, this transformer is widely used in utility substations, industrial power networks, renewable energy stations, and large commercial distribution systems. It delivers consistent voltage regulation, strong overload capability, and dependable long-term grid support.
2000kVA Three Phase Pad Mounted Transformer
2000kVA Three Phase Pad Mounted transformer adopts a fully sealed oil-immersed design, which complies with international standards such as IEC, ANSI and GB. It has the characteristics of high efficiency, low loss and strong weather resistance. It is widely used in industrial parks, commercial complexes, power companies and new energy projects, and is particularly suitable for medium and large load environments that require both stable power supply and energy saving.
NAYY-J/NAYY-O Cables
The NAYY-J/NAYY-O Solar Cables provide cost-effective, reliable power distribution in photovoltaic systems. With sector-shaped or round aluminum conductors, PVC core insulation, and robust PVC outer jacket, they meet VDE 0276 requirements. NAYY-J includes a protective earth conductor, while NAYY-O is without. These cables excel in wet environments with superior water and chemical resistance, suitable for direct burial without additional protection. UV-stabilized and mechanically strong, they withstand soil stress and installation pulling forces. Low-weight aluminum reduces handling efforts, making them popular for extensive solar parks. NAYY-J/NAYY-O Solar Cables ensure efficient energy transfer with minimal losses, supporting sustainable solar infrastructure worldwide.
H05VV-F
H05VV-F wires from NPC Electric are flexible PVC insulated and sheathed cables designed for light-duty power connections in household and commercial electrical equipment. Featuring finely stranded copper conductors, these wires provide excellent flexibility, making them easy to install and suitable for applications involving frequent movement. The double PVC insulation structure offers reliable electrical protection, good mechanical strength, and resistance to abrasion, ensuring safe operation under normal indoor conditions. Manufactured in accordance with harmonized standards, NPC Electric H05VV-F wires deliver stable conductivity, consistent insulation thickness, and dependable performance. They are widely used where flexibility, safety, and ease of handling are essential, making them a practical choice for appliances, extension cords, and portable equipment.
1600kVA Three Phase Pad Mounted Transformer
The 1600kVA Three Phase Pad Mounted Transformer is a robust, liquid-immersed, self-cooled distribution transformer designed for reliable underground power delivery in high-demand environments. Built to exceed IEEE C57.12.34, ANSI C57.12.00, DOE 2016 efficiency standards, and CSA C802.3 requirements, this UL-listed compartmental-type unit features dead-front high-voltage bushings (200A loadbreak inserts), loop-feed or radial configurations, and a fully sealed tank with mineral oil or eco-friendly FR3 fluid options.Suitable for primary voltages like 12.47kV, 13.8kV, 24.94kV, or 34.5kV to secondary 480Y/277V or 208Y/120V, it provides overload capability, low maintenance, and enhanced fire safety for modern grid integration.
Type 440 Flexible Copper Screened Mining Cable With Three Pilot Core Interstitial
The Type 440 Flexible Copper Screened Mining Cable is a medium-voltage mining cable designed for heavy-duty applications in draglines, shovels, and large drills.It features tinned annealed copper conductors, EPR insulation, and a flexible copper wire screen for superior electrical shielding. Its three pilot cores allow for enhanced monitoring and control in mining operations. The extra heavy-duty PCP sheath provides oil resistance, abrasion protection, and flame retardancy, making it suitable for harsh mining environments. Compliant with AS/NZS 2802 and related standards, this cable ensures long service life and high mechanical performance in demanding conditions. Its flexible construction allows for repeated bending and movement under harsh operating conditions. The outer sheath provides excellent resistance to abrasion, oil, moisture, impact, and environmental aging. Manufactured under strict quality control procedures, the Type 440 mining cable undergoes comprehensive raw material testing, process inspection, and finished product testing to ensure compliance with mining regulations and long-term performance.
225kVA Three Phase Pad Mounted Transformer
The 225kVA three-phase pad transformer is an efficient and reliable power conversion device designed for commercial, industrial and distribution systems. With a high power capacity of 225kVA, the transformer is able to provide a stable three-phase power supply for large-scale equipment to meet high load requirements. Its rugged housing is made of weather-resistant materials and meets NEMA 3R standards, ensuring long-term stable operation in outdoor environments and preventing the influence of external factors such as water, dust and corrosion.
170kV 4–40MVA Oil-Immersed High-Voltage Power Transformer
The 170kV 4–40MVA oil-immersed high-voltage power transformer is designed to support flexible capacity requirements across modern transmission and substation systems. Its wide MVA range allows a single platform to adapt to diverse grid configurations, from regional substations to industrial power interfaces. The transformer utilizes a refined oil-paper insulation system to ensure strong dielectric performance and long-term operational stability under high electrical stress. Advanced magnetic circuit optimization minimizes losses while maintaining excellent voltage regulation. The mechanical structure is engineered to withstand thermal cycling, short-circuit forces, and continuous operation under variable load conditions. With a focus on reliability, efficiency, and service life, this transformer is well suited for utility-scale projects that demand dependable high-voltage energy transfer with adaptable power ratings.
60kV Dyn11/Yyn0 Pure Copper Oil-Immersed Power Transformer
The 60kV Dyn11/Yyn0 Pure Copper Oil-Immersed Power Transformer is designed for regional 35–50 kV distribution networks and industrial substations. It adopts 99.99 % electrolytic pure copper windings, Class A insulation, corrugated tank + ONAN natural cooling, and energy-saving S11/S13 core with up to 40 % lower no-load loss. Standard vector groups Dyn11 or Yyn0, off-circuit tap changer ±5 % or ±2×2.5 % (on-load optional). Fully compliant with IEC 60076, lightning impulse 250 kV peak, PD <10 pC. Fully sealed or conservator design prevents oil aging and moisture ingress. Low noise ≤58 dB, strong short-circuit withstand, suitable for high-altitude and harsh environments. Vacuum oil filling + nitrogen sealing ensures>30-year lifespan. Widely used in mining, petrochemical, renewable energy, and urban 50 kV networks.
ALUMINUM CONDUCTOR ALUMINUM CLAD STEEL REINFORCED(ACSR/AW)
Aluminum Conductor Aluminum-Clad Steel Reinforced (ACSR/AW) offers enhanced protection for overhead lines, with outer 1350 aluminum strands encircling an aluminum-clad high-strength steel core. The cladding significantly boosts corrosion resistance over traditional ACSR, ideal for marine, acidic, or high-humidity settings. Steel reinforcement provides superior mechanical properties, enabling longer spans with reduced sag and higher load capacity. Electrical conductivity from aluminum layers ensures minimal transmission losses, supporting ampacities up to 20% higher in equivalents. Adhering to IEC 61089 and ASTM B549, ACSR/AW features versatile stranding options for optimized ratios. Its design facilitates easy installation and compatibility with existing hardware. Lightweight yet robust, it lowers infrastructure costs and maintenance needs. ACSR/AW promotes sustainability through better longevity and recyclability, reducing environmental impact. Widely adopted in global utilities, it delivers reliable performance in extreme conditions, from stormy coasts to industrial hubs, making it a smart choice for future-proofing power grids.
333kVA Single Phase Pad Mounted Transformer
The 333kVA Single Phase Pad Mounted Transformer is a high-performance electrical transformer designed for reliable power distribution in industrial and commercial applications. With a robust, weather-resistant enclosure, it is ideal for outdoor installations and offers efficient step-down voltage conversion. This transformer features a 333kVA capacity, providing reliable power to meet the demands of single-phase systems, and comes with customizable primary and secondary voltage configurations.
Quail ACSR Conductor Cable
Introducing the Quail ACSR Conductor Cable, a versatile 2/0 AWG overhead conductor with 6/1 stranding configuration. Composed of EC grade aluminum wires surrounding a galvanized steel core, it achieves a rated strength of 4,030 lbs and ampacity up to 250A at 75°C. Adhering to ASTM B230 for aluminum and B232 for assembly, this cable excels in corrosion resistance and mechanical endurance for spans up to 250m. The steel core enhances tensile strength to control sag under loads, while aluminum provides high conductivity (61.5% IACS) and a lightweight design for easier installation. Suitable for distribution voltages up to 138kV, the Quail ACSR Conductor Cable reduces line losses and withstands extreme weather, including ice loads up to 1/2 inch. Its economic profile makes it a staple for utility expansions, renewable integrations, and grid modernization, delivering consistent power with high weather tolerance and minimal maintenance in global overhead networks.
1/0 Janthina Aluminum Conductor Triplex Overhead Service Drop Cable
The 1/0 Janthina Triplex Service Drop Cable is a reliable overhead cable for secondary power distribution to residential service entrances. Featuring two 1/0 AWG aluminum phase conductors and one neutral messenger (7-strand) insulated with XLPE or PE and assembled in triplex configuration, it provides excellent mechanical strength and weather resistance. Compliant with ASTM B-230, B-231, ICEA S-76-474, and ANSI/ICEA standards, this cable supports 600V applications with high UV, moisture, and abrasion protection. The self-supporting messenger reduces sag and simplifies installation over medium spans. The 1/0 Janthina Triplex Service Drop Cable ensures low power losses, high current capacity, and long service life in harsh outdoor conditions. Lightweight and flexible, it is widely used for two-phase service drops with neutral in urban, suburban, and rural areas requiring safe, cost-effective aerial connections from utility poles to homes.
ALUMINUM CONDUCTOR ALLOY REINFORCED(ACAR)
Aluminum Conductor Alloy Reinforced (ACAR) is a high-performance overhead conductor featuring concentrically stranded 1350-H19 aluminum wires around a core of 6201 aluminum-magnesium-silicon alloy strands. This design optimizes the balance between electrical conductivity and mechanical strength, offering higher ampacity than equivalent AAAC and better strength-to-weight ratio than AAC. ACAR excels in applications requiring reduced sag and enhanced durability, with excellent corrosion resistance suitable for coastal or industrial settings. Compliant with ASTM B524, B231, and B398 standards, it supports various stranding configurations for flexibility in line design. The alloy reinforcement provides superior tensile strength (up to 30% more than pure aluminum), minimizing support structures and installation costs. Ideal for primary and secondary distribution, ACAR reduces energy losses while maintaining reliability under heavy loads or extreme weather. Its lightweight nature facilitates easier handling, and full aluminum construction ensures recyclability, aligning with sustainable power infrastructure goals. ACAR is a versatile choice for modern grids seeking efficiency and longevity.