AAAC Conductor and Triplex Cables for Edenorte Project in the Dominican Republic
The AAAC Conductor and Triplex Cables produced by NPC have passed strict quality inspection by engineers and will be sent to the Dominican Republic in the near future.

NPC Electric is proud to announce the successful supply of AAAC 2/0 conductor and various Triplex cables to support the Edenorte project in the Dominican Republic. This achievement highlights our ongoing commitment to providing high-quality electrical solutions for utility companies across Latin America.
For this project, we supplied the following products:
AAAC 2/0 Conductor
Alambre Triplex #06
Alambre Triplex #02
Alambre Triplex #04
Alambre Triplex 1/0 AWG
Alambre Triplex 2/0 AWG
Our AAAC (All Aluminum Alloy Conductor) is known for its excellent conductivity, corrosion resistance, and lightweight performance — ideal for overhead power distribution. The Triplex service drop cables were customized to meet Edenorte’s technical specifications and were rigorously tested for durability and efficiency in tropical environments. We offer comprehensive low voltage cable solutions to help you achieve engineering success.
This supply is another milestone in our growing presence in the Caribbean market. With reliable logistics, strict quality control, and responsive customer service, NPC Electric continues to support major infrastructure projects across the region.
Related Articles
Related Products
2/0 Nassa Aluminum Conductor Triplex Overhead Service Drop Cable
The 2/0 Nassa Aluminum Conductor Triplex Overhead Service Drop Cable is designed for reliable overhead electrical service connections between utility distribution lines and end users. The cable structure includes two insulated aluminum phase conductors twisted around a bare aluminum neutral messenger, providing excellent electrical performance and mechanical strength. Manufactured with high-purity aluminum and durable, weather-resistant insulation, the 2/0 Nassa Aluminum Conductor Triplex Overhead Service Drop Cable offers low electrical resistance, corrosion resistance, and long-term stability in outdoor environments. Its lightweight design allows for efficient installation while maintaining the tensile strength required for aerial applications. The cable is engineered to perform under UV exposure, wind load, and temperature variations. Comprehensive quality control and systematic testing are applied throughout production to ensure compliance with industry standards and dependable service performance.
15kV Concentric Neutral Power Cable
The 15kV Concentric Neutral Power Cable is a premium medium-voltage underground distribution cable designed for reliable primary power delivery in distribution networks. It features a stranded copper or aluminum conductor, extruded semi-conducting conductor shield, TR-XLPE or EPR insulation, semi-conducting insulation shield, and helically applied bare copper concentric neutral wires, all protected by a tough sunlight-resistant LLDPE jacket. Available in 100% or 133% insulation levels with full or reduced neutral, this cable provides excellent electrical performance, moisture resistance, and mechanical protection. Suitable for direct burial or duct installations, the 15 kV Concentric Neutral Power Cable meets ICEA S-94-649, AEIC CS8, and related standards. It undergoes rigorous quality testing from raw materials to finished product, ensuring long-term reliability, low dielectric loss, and high resistance to water treeing in demanding underground environments.
Instrumentation Cables—Mica Tapped, XLPE Insulated, Overall Screened, Wire Armoured LSZH Sheathed Fire-Resistant Cables(CU/GMT/XLPE/OSCR/SWA/LSZH)
Instrumentation Cables with Mica Taped, XLPE Insulated, Overall Screened, Wire Armoured and LSZH Sheathed construction (CU/GMT/XLPE/OSCR/SWA/LSZH) are designed for critical signal transmission in fire-risk and safety-sensitive environments. The copper conductor is wrapped with mica tape to maintain circuit integrity under fire conditions, while XLPE insulation ensures stable electrical performance and thermal resistance. The overall screen reduces electromagnetic interference, enabling accurate signal transmission in industrial systems. Steel wire armouring provides mechanical protection against impact and external stress, making the cable suitable for harsh installation conditions. The LSZH outer sheath limits smoke emission and toxic gases during fire, enhancing personnel safety. These fire-resistant instrumentation cables are widely used where continuous operation and reliable signal control are essential, even in extreme conditions.
1033.5 MCM Bluebell AAC All Aluminum Bare Conductor Cable
The 1033.5 MCM Bluebell AAC Cable represents premium All Aluminum Conductor technology for overhead power applications. Built with 37 strands of high-conductivity 1350-H19 aluminum, this bare conductor delivers an optimal balance of electrical efficiency and mechanical robustness. With a 1.170-inch diameter, 17,900 lbs breaking strength, and 1033 amps ampacity, the Bluebell AAC offers low DC resistance of 0.0167 ohms per 1000 ft at 20°C and a weight of 970.3 lbs per 1000 ft. This design minimizes sag while providing excellent corrosion resistance for extended outdoor service. Manufactured to meet ASTM B-230 and B-231 standards, the 1033.5 MCM Bluebell AAC Cable undergoes extensive quality testing from raw materials through finished product. It is the ideal solution for new installations and upgrades in transmission and distribution systems that demand lightweight, high-conductivity bare aluminum conductors.
Penguin ACSR Conductor Cable
The ACSR Penguin is an Aluminium Conductor Steel Reinforced (ACSR) designed with a robust steel core surrounded by layers of high-conductivity aluminium wires, adhering to ASTM B232 standards. It features a stranded steel core surrounded by layers of aluminum conductors, combining excellent tensile strength with efficient current-carrying capability. The steel core provides superior load-bearing capacity, while the aluminum strands ensure low electrical resistance and reduced line losses. This balanced construction allows the Penguin ACSR Conductor Cable to withstand long spans, high wind loads, and varying environmental conditions. Manufactured in accordance with relevant ASTM and IEC standards, it offers stable performance, ease of installation, and long service life. The conductor is widely adopted in overhead transmission lines where durability, economy, and mechanical reliability are critical.
2 Cockle Aluminum Conductor Triplex Overhead Service Drop Cable
The 2-2-4 Cockle Aluminum Conductor Triplex Overhead Service Drop Cable is engineered for efficient overhead power supply from utility poles to residential or commercial weatherheads. It consists of two concentric-lay-stranded 1350-H19 aluminum phase conductors (#2 AWG, 7-strand), black cross-linked polyethylene (XLPE) insulation for superior weather, UV, and thermal resistance, and a bare ACSR neutral messenger (#4 AWG, 6/1) providing mechanical strength and conductivity. Rated for 600 volts phase-to-phase at conductor temperatures up to 90°C (XLPE) or 75°C (Poly), it offers an allowable ampacity of approximately 150 amps (XLP). Compliant with ASTM B-230, B-231, B-232, B-399, and ICEA S-76-474 standards, this lightweight, flexible cable facilitates straightforward installation and ensures long-term reliability in harsh outdoor environments, including exposure to wind, ice, moisture, and temperature variations.
4 Periwinkle Aluminum Conductor Triplex Overhead Service Drop Cable
The 4-4-6 Periwinkle Aluminum Conductor Triplex Overhead Service Drop Cable is a cost-effective solution for overhead power delivery from utility poles to residential or light commercial weatherheads. It features concentric-lay-stranded 1350-H19 aluminum phase conductors (#4 AWG, 7-strand), black cross-linked polyethylene (XLPE) insulation for superior weather, UV, and thermal resistance, and a bare ACSR neutral messenger (#6 AWG, 6/1) providing mechanical strength and conductivity. Rated for 600 volts phase-to-phase at conductor temperatures up to 90°C (XLPE) or 75°C (Poly), it offers an allowable ampacity of approximately 100 amps (XLP). Compliant with ASTM B-230, B-231, B-232, B-399, and ICEA S-76-474 standards, this lightweight, flexible cable ensures easy installation and reliable performance in outdoor conditions, including wind, ice loading, moisture, and temperature fluctuations.
Mobile Prefabricated Substation
The Mobile Prefabricated Substation is a fully integrated, factory-assembled power solution designed for rapid deployment in emergency, temporary, or permanent power distribution applications. Built on a robust skid or trailer-mounted platform, it combines high-voltage switchgear, cast resin or oil-immersed transformer, low-voltage switchgear, protection relays, metering, and auxiliary systems into a compact, weatherproof enclosure. This plug-and-play design enables fast installation and commissioning, significantly reducing on-site construction time. With advanced safety features, intelligent monitoring, and high reliability, the mobile substation delivers stable power supply while offering excellent flexibility for load changes and network expansions. It is ideal for utilities, industrial projects, mining operations, and events requiring quick and dependable power infrastructure.
NYY-J / NYY-O 0.6/1kV Low Voltage Power Cable
NYY-J / NYY-O 0.6/1kV are low voltage power cables designed according to VDE 0276 standard, suitable for fixed installation in indoor, outdoor, and underground, cable ducts or concrete (not exposed to mechanical stress or vibration). It uses copper conductors to deliver stable electrical performance and features a durable outer sheath that protects against mechanical damage, moisture, and chemical exposure. NYY-J cables incorporate a protective earth conductor for enhanced safety, while NYY-O cables are supplied without an earth conductor for specific system designs. Designed for a rated voltage of 0.6/1kV and manufactured in compliance with IEC requirements, the cable is suitable for indoor and outdoor use, including installation in ducts, concrete, or underground. Its balanced construction supports long-term reliability, easy installation, and low maintenance costs in demanding operating environments.
H01N2-D EN 50525-2-81 Welding Cable
The H01N2-D EN 50525-2-81 Welding Cable is an ultra-flexible, heavy-duty single-core cable specifically developed for professional welding applications. It features extremely fine-stranded class 5 copper conductors for maximum flexibility and high current-carrying capacity, heat-resistant rubber insulation and outer sheath providing excellent thermal stability (up to 85–90°C continuous, 200°C short-term), superior oil resistance, flame retardancy (IEC 60332-1), abrasion/tear resistance, and weatherproofing. Compliant with EN 50525-2-81 (HD 22.6 S2) standard and rated 100 V, it supports very tight bending radii, frequent reeling, and reliable performance even under intense mechanical stress and welding heat. The H01N2-D is the industry standard choice for electrode holders, earth returns, welding machines, and portable high-current connections in workshops, shipbuilding, construction, and industrial environments where extreme flexibility and durability are required.
400kVA Oil Immersed Transformer
The 400kVA Oil Immersed Transformer produced by our company adopts a new insulation structure to improve the short-circuit resistance; the iron core is made of high-quality cold-rolled silicon steel sheet; the high-voltage winding is made of high-quality oxygen-free copper wire and adopts a multi-layer cylindrical structure; all fasteners are treated with special anti-loosening treatment. ONAN cooling, aluminum or copper windings, high-voltage 34.5kV / 24.94kV / 13.8kV / 12.47kV / 4.16kV (delta or wye), low-voltage 480Y/277V, 208Y/120V, 600Y/347V or custom, ±2×2.5% HV taps.
477 MCM HAWK ACSR Conductor Cable
The 477 MCM HAWK ACSR Conductor Cable is a robust and highly efficient Aluminium Conductor Steel Reinforced (ACSR) cable engineered for overhead transmission and distribution networks. It consists of 26 hard-drawn 1350-H19 aluminium wires concentrically stranded around 7 galvanized steel wires, delivering an optimal blend of electrical conductivity and mechanical strength. Designed and manufactured in accordance with ASTM B232, the HAWK configuration is well-suited for long-span overhead lines, where elevated tensile performance is required to withstand environmental loads like wind and ice. The galvanized steel core, available in Class A or B, offers superior corrosion resistance, while the aluminium strands ensure high current-carrying capacity with low resistivity. This conductor is a popular choice in transmission infrastructure due to its balance of strength, weight, and performance, making it a cost-effective and reliable solution in a wide range of operating environments.
500kVA Single Phase Pad Mounted Transformer
The 500kVA Single Phase Pad Mounted Transformer is a high-capacity electrical transformer designed for reliable and efficient power distribution in commercial, industrial, and utility applications. With a robust, weatherproof enclosure, it is specifically built for outdoor use and can handle the demanding requirements of larger single-phase systems. This transformer offers a 500kVA capacity, ensuring dependable performance for a variety of load conditions.
90kV Three-Phase Oil-Immersed Power Transformer
The 90kV Three-Phase Oil-Immersed Power Transformer for High-Voltage Distribution is engineered to deliver reliable and efficient performance across utility grids, industrial substations, and high-voltage transmission systems. Designed with high-grade silicon steel cores and 100% copper windings, the transformer ensures low losses, strong short-circuit resistance, and stable thermal performance. Its oil-immersed cooling structure provides superior heat dissipation, supporting continuous and heavy-duty operation. The robust tank, high-performance insulation system, and outdoor-ready protection structure enable safe operation in harsh climate conditions. Compliant with IEC, IEEE, and GB standards, the transformer offers excellent voltage stability, long service life, and high operational reliability. It is widely used in power utilities, infrastructure projects, renewable energy integration, and industrial distribution networks requiring dependable high-voltage transformation.