3MVA Substation Transformers successfully shipped and will soon be sent to Guyana Power&Light Inc
The world's leading power equipment manufacturer NPC Electric Group announced today that its independently developed 3MVA substation transformer has been successfully produced and passed strict quality inspection, and will soon be sent to Guyana Power&Light Inc.
13.8kV - 0.48Y/0.22kV, 3MVA substation transformers
We are pleased to announce the successful shipment of two units of 13.8kV - 0.48Y/0.22kV, 3MVA substation transformers to Guyana Power & Light Inc. These transformers are designed to deliver reliable performance and efficient power distribution, supporting the continued development of Guyana’s energy infrastructure. And we provide a series of technical support, including product catalogs, installation manuals, user manuals, maintenance manuals, etc.
This shipment marks another step forward in our commitment to providing high-quality transformer solutions to clients across the globe. We are proud to support Guyana Power & Light Inc. in their mission to enhance the country’s electrical grid and ensure stable power supply to communities and industries.
NPC Pole Mounted Transformer and Pad Mounted Transformers
Meanwhile, we can also manufacture the pole-mounted transformer and pad-mounted transformers.

Related Articles
Related Products
380kV Oil-Immersed Power Transformer
NPC Electric 380kV Oil-Immersed Power Transformer is engineered for the most demanding extra-high voltage (EHV) transmission networks, providing a robust link between power generation and regional distribution. Utilizing a multi-step core stacking method with high-grade, laser-scribed silicon steel, this unit minimizes eddy current losses and vibration. The internal active part is submerged in high-dielectric-strength mineral oil, which serves both as a superior insulator and a high-efficiency coolant. Designed with a vacuum-proof, reinforced corrugated or radiator-type tank, it ensures hermetic integrity under extreme thermal cycling. With advanced electrostatic shielding and a focus on mechanical stability, this transformer offers unparalleled reliability for national grid backbones, ensuring continuous power flow with minimal maintenance requirements even in harsh environmental conditions.
ALUMINUM CONDUCTOR ALUMINUM CLAD STEEL REINFORCED(ACSR/AW)
Aluminum Conductor Aluminum-Clad Steel Reinforced (ACSR/AW) offers enhanced protection for overhead lines, with outer 1350 aluminum strands encircling an aluminum-clad high-strength steel core. The cladding significantly boosts corrosion resistance over traditional ACSR, ideal for marine, acidic, or high-humidity settings. Steel reinforcement provides superior mechanical properties, enabling longer spans with reduced sag and higher load capacity. Electrical conductivity from aluminum layers ensures minimal transmission losses, supporting ampacities up to 20% higher in equivalents. Adhering to IEC 61089 and ASTM B549, ACSR/AW features versatile stranding options for optimized ratios. Its design facilitates easy installation and compatibility with existing hardware. Lightweight yet robust, it lowers infrastructure costs and maintenance needs. ACSR/AW promotes sustainability through better longevity and recyclability, reducing environmental impact. Widely adopted in global utilities, it delivers reliable performance in extreme conditions, from stormy coasts to industrial hubs, making it a smart choice for future-proofing power grids.
630kVA Three-Phase Oil-Immersed Outdoor Substation Transformer | 220V to 380V Step-Up Transformer
This 630kVA three-phase oil-immersed transformer is designed for outdoor substations, providing reliable voltage conversion from 220V to 380V. With a robust oil-immersed cooling system, it ensures excellent heat dissipation, stable performance, and long service life. Ideal for industrial facilities, commercial power distribution, and utility applications, this step-up transformer delivers consistent efficiency even under heavy load conditions.
4 AWG SWANATE ACSR Conductor Cable
4 AWG SWANATE ACSR Conductor Cable is designed for overhead power distribution systems requiring dependable electrical performance and enhanced mechanical strength. It is manufactured using concentrically stranded aluminum wires reinforced with a galvanized steel core, ensuring an effective balance between conductivity and tensile durability. The aluminum strands provide low electrical resistance and efficient current transfer, while the steel core improves load-bearing capacity, controls sag, and increases resistance to mechanical stress during installation and operation. This construction allows the 4 AWG SWANATE ACSR conductor to perform reliably under wind load, temperature variation, and outdoor environmental conditions. Produced in accordance with ASTM and IEC standards, the 4 AWG SWANATE ACSR Conductor Cable offers consistent quality, easy handling, and long service life. It is widely applied in utility distribution lines, rural electrification projects, and overhead network upgrades where stable performance and cost efficiency are required.
2000kVA 33kV Oil-Immersed Earthing Transformer with NGR
2000kVA 33kV Oil-Immersed Neutral Grounding Earthing Transformer with NGR is engineered to provide a stable and controlled neutral point for medium-voltage power systems. By combining an earthing transformer with an integrated Neutral Grounding Resistor (NGR), it effectively limits earth fault current, improves system protection coordination, and enhances operational safety. The oil-immersed design ensures excellent insulation performance, efficient heat dissipation, and long-term reliability under continuous operation. Optimized magnetic core construction reduces losses, while robust windings withstand short-time fault currents without mechanical degradation. The integrated NGR is precisely matched to system requirements, enabling accurate fault current limitation and minimizing damage to equipment during ground faults.
5000kVA Dry Type Transformer
The NPC ELECTRIC 5000kVA Dry Type Transformer is a high-capacity, reliable power solution designed for large-scale industrial and commercial operations. With a robust 5000kVA rating, it features advanced dry-type insulation technology for enhanced safety, low maintenance, and long-lasting performance. Engineered for demanding environments, this transformer ensures stable, efficient, and quiet operation while minimizing environmental impact. It achieves efficiencies around 99.48% at 35% load per DOE 2029 levels for three-phase low-voltage dry-type at 5000 kVA (aligned/interpolated from published tables showing progressive gains and 20% loss reduction from prior baselines), accommodates high harmonics, overloads, and ensures long-term reliability with reduced environmental footprint and operational expenses.
NA2XBY 0.6/1kV Low Voltage Power Cable
NA2XBY 0.6/1kV are low voltage power cables designed according to EN 60228 standard, suitable for fixed installation in indoor, outdoor, underground, Cable ducts, conduits, or concrete (not subject to vibration) environments. Featuring stranded aluminium conductors, cross-linked polyethylene (XLPE) insulation, PVC bedding, galvanized steel wire armour (SWA), and PVC outer sheath, it complies with IEC 60502-1 standards. The lightweight aluminium reduces material and installation costs while the SWA provides robust mechanical protection against impacts and rodents, ideal for direct burial. With low dielectric losses, high thermal stability, and good moisture resistance, it ensures efficient transmission in demanding environments. Flame-retardant and durable, the NA2XBY 0.6/1kV Low Voltage Power Cable offers long service life with minimal maintenance. Perfect for industrial sites, infrastructure projects, commercial developments, and utility networks requiring reliable, protected low-voltage underground power supply.
(N)TSCGEWOU 3.6/6kV, 6/10kV, 8.7/15kV and 12/20kV ATB Cable
The (N)TSCGEWOU 3.6/6kV, 6/10kV, 8.7/15kV, and 12/20kV ATB Cable is a medium voltage flexible power cable designed in compliance with VDE 0250 standards. It features Class 5 tinned copper conductors, EPR rubber insulation, semi-conductive layers, halogen-free flame-retardant rubber sheath, and an earth detection conductor. The ATB construction ensures superior mechanical strength, oil resistance, abrasion resistance, and flame retardancy, making it ideal for open-pit mining, tunneling, and other heavy-duty mobile equipment applications under extreme mechanical stress. It includes tinned class 5 copper phase conductors, semi-conductive screens, EPR insulation for reliable dielectric and thermal performance (90°C rating), copper braid screen, control conductors, monitoring conductor (ÜL), anti-torsion braid to reduce twisting under load, and a robust rubber sheath resistant to oils, flames, abrasion, and mechanical damage.
25000kVA Oil-Immersed Copper Transformer For Substation
The 25,000kVA oil-immersed copper transformer is engineered for high-standard power distribution in large industrial facilities, utility networks, and high-voltage substations. Built with premium pure copper windings, it delivers exceptional electrical conductivity, reduced losses, and long-term operational stability. The oil-immersed cooling system ensures efficient heat dissipation, allowing the transformer to perform reliably under continuous heavy load conditions.
300kVA Single Phase Pad Mounted Transformer
300kVA Single Phase Pad Mounted Transformer is a compact and efficient solution tailored for underground residential distribution (URD) systems and loop-feed applications. This fully sealed, oil-immersed transformer features high-efficiency electrical steel cores and robust aluminum or copper windings to deliver minimal losses and superior voltage regulation from high-voltage inputs like 13.8kV or 34.5kV down to 120/240V or 277/480V secondary. The environmentally friendly PCB-free dielectric fluid ensures excellent cooling and insulation while meeting ANSI/IEEE standards for loop or radial feed configurations. Ideal for urban and suburban settings, this pad-mounted transformer provides quiet operation, high overload capacity.
CONCENTRIC CABLE
NPC Electric Concentric Cable is designed with a central phase conductor surrounded by an evenly distributed concentric neutral conductor, providing a stable electrical return path and enhanced system safety. The concentric construction ensures uniform current distribution, reduces electromagnetic interference, and improves grounding reliability. High-purity copper or aluminum conductors are combined with durable insulation materials that offer excellent resistance to moisture, heat, and environmental stress. This cable structure is widely used in low-voltage power distribution, where mechanical protection and electrical stability are critical. The concentric neutral layer also enhances fault current handling and minimizes voltage drop during operation. With strong mechanical strength, long service life, and consistent electrical performance, concentric cables are suitable for underground installation and utility networks requiring dependable power delivery.
30kVA Single Phase Pole Mounted Transformer
NPC Electric's 30kVA Single Phase Pole Mounted Transformer is a compact, high-efficiency single-phase distribution transformer designed for overhead pole installation in 50/60Hz AC rural and suburban networks, with primary voltages up to 35kV (common 12.47kV/13.2kV/13.8kV/34.5kV) and secondary at 120/240V or 240/480V split-phase. It utilizes a hermetically sealed cylindrical tank with high-strength steel construction and radiator fins for natural oil circulation (ONAN cooling), providing excellent thermal management, corrosion resistance via epoxy coatings, and a maintenance-free lifespan over 25 years. Featuring low-loss grain-oriented silicon steel core for reduced no-load losses (typically 100-150W), high-purity copper windings, and premium mineral insulating oil (IEC 60296 compliant, dielectric strength >45kV/2.5mm), it minimizes load losses (around 500-700W at 75°C), supports overloads up to 125% continuous, operates quietly (<50dB), and achieves efficiency >98.5%. Compliant with IEEE C57.12.20, ANSI C57.12.28, DOE efficiency standards, and CSA C2.1, this transformer optimizes energy distribution, lowers operational costs, and enhances reliability for single-phase residential, farm, and light commercial loads.
397.5 MCM CHICKADEE ACSR Conductor Cable
The ACSR Chickadee is a compact yet high-performance aluminium conductor steel reinforced cable, engineered for efficient energy transmission in overhead power systems. Constructed with hard-drawn 1350-H19 aluminium wires helically stranded around a galvanized steel core, this conductor is optimized to provide excellent electrical conductivity along with the mechanical strength needed for long-span and high-load applications. Compliant with ASTM B232 standards, the Chickadee conductor is suitable for primary and secondary bare cable use in transmission and distribution networks. The galvanized steel core, treated with Class A or B coating, ensures long-term corrosion resistance, even in aggressive outdoor environments. Ideal for compact power line installations or regions with light-to-moderate mechanical stress, Chickadee offers a reliable and cost-effective solution without compromising performance or safety.
45kVA Three Phase Pad Mounted Transformer
The 45 kVA pad-mounted transformer meets ANSI, CSA, NEMA, IEEE, and DOE standards. The compartmental dead-front enclosure features tamper-resistant doors, mineral oil or ester fluid insulation, and ONAN cooling for a 65°C temperature rise, enabling quiet, overload-capable operation in outdoor pad installations.