The (N)TSCGECEWOU 8.7/15kV and 12/20kV ATB (Ground Check Conductor) Cable is a flexible medium-voltage cable enhanced with anti-torsion braid (ATB) and ground check conductor (GCC) for superior stability and safety monitoring in mining. It comprises tinned class 5 copper phase conductors, semi-conductive screens, EPR insulation for reliable dielectric/thermal performance, copper braid screen, control conductors, dedicated ground check conductor for fault detection, anti-torsion braid to reduce twisting under heavy loads, and a robust rubber sheath resistant to oils, flames, abrasion, and mechanical damage. Compliant with DIN VDE 0250, it offers high flexibility, torsional strength, and EMC protection for dynamic applications. The (N)TSCGECEWOU ATB GCC ensures dependable higher-voltage MV power with ground continuity monitoring for heavy mobile machinery such as excavators, draglines, and tunnel boring equipment in opencast and underground mining.
Voltage Rating Uo/U 8.7/15kV | 12/20kV
Test Voltage 8.7/15kV: 24kV
12/20kV: 29kV
Temperature Rating Fixed: -40°C to +80°C
Flexed: -25°C to +80°C
Minimum Bending Radius Fixed: 6 x overall diameter
Flexed: 10 x overall diameter
Maximum Short Circuit Temperature +250°C
Construction
Technical Specifications
Quality Control
Application

Construction

(N)TSCGECEWOU 8.7/15kV and 12/20kV ATB Cable (Ground Check Conductor) Constrution
(N)TSCGECEWOU 8.7/15kV and 12/20kV ATB Cable (Ground Check Conductor)

Phase Conductor

Class 5 tinned copper conductor

Insulation

Rubber compound

Earth Conductor

Individual copper braid
2 x copper earth conductors
1 x copper checking earth wiring conductor

Central Filler

Rubber compound on a polyester textile support

Inner Sheath

Abrasion-resistant rubber compound

Anti-Torsion Braid

Polyester braid between the inner and outer sheath

Outer Sheath

Abrasion-resistant rubber compound

Sheath Colour

Yellow

Manufacturer Standard

VDE 0250 Part 813, VDE 0295, EN 60228

Flame Retardant

IEC/EN 60332-1-2

Semi-Conductive Layers

Semi-conductive tape over the conductor and inner and outer
Semi-conductive rubber layer on the insulation

Application

(N)TSCGECEWOU 8.7/15kV and 12/20kV ATB cables are suitable for powering heavy mobile equipment such as excavators, loaders and drills that are subject to extreme mechanical stress and wear during traction operations in open pit mines. The cables have an earth detection conductor and are suitable for use in harsh indoor and outdoor environments.

Technical Specifications

(N)TSCGECEWOU 8.7/15kV and 12/20kV ATB Cable (Ground Check Conductor)
(N)TSCGECEWOU 8.7/15kV ATB Cable (Ground Check Conductor)
(N)TSCGECEWOU 12/20kV ATB Cable (Ground Check Conductor)

No. Of Cores
(PHASE+EARH +

GROUND CHECK CONTROL)

Nominal Cross Sectional Area
mm²

CONDUCTOR

DIAMETER

MINIMUM OVERALL

DIAMETER

MAXIMUM OVERALL

DIAMETER

MAXIMUM

TENSILE LOAD

NOMINAL

WEIGHT

Phase N

Conductor

Earth

Conductor

Control

Conductor

mm mm mm N kg/km
3+2+1 25 25/2 10 6.8 53.9 59.3 1125 4490
3+2+1 35 25/2 10 7.8 55.3 60.8 1575 4920
3+2+1 50 25/2 10 9.4 58.5 64.2 2250 5700
3+2+1 70 35/2 10 11.2 64.2 70.5 3150 7200
3+2+1 95 50/2 10 12.7 67.9 74.4 4257 8480

No. Of Cores
(PHASE+EARH +

GROUND CHECK CONTROL)

Nominal Cross Sectional Area
mm²

CONDUCTOR

DIAMETER

MINIMUM OVERALL

DIAMETER

MAXIMUM OVERALL

DIAMETER

MAXIMUM

TENSILE LOAD

NOMINAL

WEIGHT

Phase N

Conductor

Earth

Conductor

Control

Conductor

mm mm mm N kg/km
3+2+1 25 25/2 10 6.8 58.2 63.9 1125 5110
3+2+1 35 25/2 10 7.8 59.8 65.7 1575 5580
3+2+1 50 25/2 10 9.4 64.6 70.9 2250 6550
3+2+1 70 35/2 10 11.2 68.3 74.8 3150 780

Quality Control

(N)TSCGECEWOU 8.7/15kV and 12/20kV ATB Cable (Ground Check Conductor)
(N)TSCGECEWOU 8.7/15kV and 12/20kV ATB Cable (Ground Check Conductor) Raw Material Test

Raw Material Test

Raw Material Test for (N)TSCGECEWOU 8.7/15kV and 12/20kV ATB (Ground Check Conductor) Cable prioritizes ATB/GCC compliance for mining safety. Steps include: Certification Verification: Tinned copper, EPR, rubber sheath, anti-torsion braid, and ground check conductor meet VDE 0250/IEC specs. Conductor Testing: Tensile, elongation, conductivity, tin coating analysis (including GCC).Insulation/Screen Evaluation: EPR dielectric/thermal; semi-conductive properties.Sheath & ATB Checks: Abrasion/oil/flame resistance, anti-torsion braid tensile/torsional performance.GCC & Braid Validation: Ground check continuity, coverage, strength, and conductivity.

(N)TSCGECEWOU 8.7/15kV and 12/20kV ATB Cable (Ground Check Conductor) Process inspection

Process inspection

Process Inspection for (N)TSCGECEWOU 8.7/15kV and 12/20kV ATB (Ground Check Conductor) Cable enforces precision. The procedure features: Stranding Control: Uniform tinned copper phases/control/GCC.Extrusion Monitoring: Semi-conductive screens, EPR insulation with defect detection. Screening & ATB/GCC: Precise braid application, anti-torsion integration, GCC assembly.Real-Time Checks: Resistance, integrity, diameter, ground check continuity. Optimization: Extrusion parameters adjusted. Correction: Immediate fixes. This guarantees the (N)TSCGECEWOU 8.7/15kV and 12/20kV ATB (Ground Check Conductor) Cable excels in MV electrical, torsional, and ground monitoring performance.

(N)TSCGECEWOU 8.7/15kV and 12/20kV ATB Cable (Ground Check Conductor) Finished Product

Finished Product

Finished Product Test validates the (N)TSCGECEWOU 8.7/15kV and 12/20kV ATB (Ground Check Conductor) Cable for deployment. Steps include: Inspection: Visual/dimensional/marking verification. Electrical: Resistance, insulation, withstand (24–29kV), partial discharge, GCC continuity/functionality. Mechanical: Bending, tensile, abrasion, torsional (ATB) checks. Performance: Oil/flame/thermal aging verification. Validation: Voltage rating and short-circuit capability confirmed.Release: Only passing (N)TSCGECEWOU 8.7/15kV and 12/20kV ATB (Ground Check Conductor) Cable approved for dependable mining MV use with ground check safety.

Application

Ideal for (N)TSCGECEWOU 8.7/15kV and 12/20kV ATB (Ground Check Conductor) Cable in opencast mining trailing, heavy mobile equipment (excavators, draglines, shovels), tunnel boring power feeds, conveyor systems, and reeling drums prioritizing anti-torsion, ground fault detection, flexible screened MV cable, and mechanical protection in harsh environments.

Technical Advantages

● 30+ years of manufacturing experience
● ISO and UL certified production
● Customized cable and transformer solutions

Product Packaging

Wires and Cables packaging (1)
Wires and Cables packaging (1)
Wires and Cables packaging (2)
Wires and Cables packaging (2)
Wires and Cables packaging (3)
Wires and Cables packaging (3)
Wires and Cables packaging (4)
Wires and Cables packaging (4)
Wires and Cables packaging (5)
Wires and Cables packaging (5)
Wires and Cables packaging (6)
Wires and Cables packaging (6)
Wires and Cables packaging (7)
Wires and Cables packaging (7)
Wires and Cables packaging (8)
Wires and Cables packaging (8)

Related Products

FAQ From Customers

What are the advantages of power cables and overhead lines?
(1) Reliable operation, because it is installed in a hidden place such as underground, it is less damaged by external forces, has less chance of failure, and the power supply is safe, and it will not cause harm to people;
(2) The maintenance workload is small and frequent inspections are not required;
(3) No need to erect towers;
(4) Help improve power factor.
Which aspects should be considered when choosing the cross section of a power cable?
(1) The long-term allowable working current of the cable;
(2) Thermal stability once short circuited;
(3) The voltage drop on the line cannot exceed the allowable working range.
What are the measures for cable fire prevention?
(1) Use flame-retardant cables;
(2) Use fireproof cable tray;
(3) Use fireproof paint;
(4) Fire partition walls and fire baffles are installed at cable tunnels, mezzanine exits, etc.;
(5) Overhead cables should avoid oil pipelines and explosion-proof doors, otherwise local pipes or heat insulation and fire prevention measures should be taken.
What should be paid attention to during the transportation and handling of cables?
(1) During transportation, loading and unloading, cables and cable reels should not be damaged. It is strictly forbidden to push the cable reels directly from the vehicle. Generally, cables should not be transported and stored flat.
(2) Before transporting or rolling the cable reel, ensure that the cable reel is firm, the cable is wound tightly, the oil pipe between the oil-filled cable and the pressure oil tank should be fixed without damage, the pressure oil tank should be firm, and the pressure indication should meet the requirements.
What inspections should be carried out for the acceptance of cable lines?
(1) The cable specifications should meet the regulations, the arrangement should be neat, no damage, and the signs should be complete, correct and clear;
(2) The fixed bending radius of the cable, the related distance and the wiring of the metal sheath of the single-core power cable should meet the requirements;
(3) The cable terminal and the middle head should not leak oil, and the installation should be firm. The oil pressure of the oil-filled cable and the meter setting should meet the requirements;
(4) Good grounding;
(5) The color of the cable terminal is correct, and the metal parts such as the bracket are completely painted;
(6) There should be no debris in the cable trench, tunnel, and bridge, and the cover should be complete.