x
Type 455 Flexible Screened Mining Cable with two earth and one pilot core
Type 455 Flexible Screened Mining Cable with two earth and one pilot core

Type 455 Flexible Screened Mining Cable With Two Earth And One Pilot Core

The Type 450 Flexible Copper Screened Mining Cable is a medium-voltage, heavy-duty mining cable designed for power supply in draglines, slow reeling, and industrial applications requiring two earth cores and one pilot core. It features tinned annealed copper conductors, EPR (XR-EP-90) insulation, and a tinned copper/polyamide braid screen for electrical shielding. The double-layer HD-PCP sheath provides extra heavy-duty protection, including oil resistance, flame retardancy, and chemical durability. Available in voltage ratings from 3.3kV to 33kV, the cable meets AS/NZS 2802 and related standards, ensuring high performance and reliability in harsh mining environments.
Voltage Rating Type 450.3 - 3.3kV
Type 450.6 - 6.6kV
Type 450.11 - 11kV
Type 450.22 - 22kV
Type 450.33 - 33kV
Temperature Rating -25°C to +90°C
Construction
Technical Specifications
Quality Control
Application

Construction

Type 455 Flexible Screened Mining Cable with two earth and one pilot core Constrution
Type 455 Flexible Screened Mining Cable With Two Earth And One Pilot Core

Conductor

Tinned anneaIed copper wires

Insulation

EPR (Ethylene Propylene Rubber) type XR-EP-90

Conductor Screen

Semi-conductive tape + thermosetting compound

Insulation Screen

Semi-conductive thermosetting compound

Cable Assembly

Three screened power, two earth and one pilot core laid up with right hand direction on the rubber centre filler

Screen

Tinned copper/polyamide braid

Inner Sheath

Semi-conductive thermosetting compound

Armour

Polyamide yarns

Outer Sheath

HD-CSP (Heavy-duty Chlorosulphonated Polyethylene) - extra heavy duty, oil resistant and flame retardant

Sheath Colour

Black

Manufacturer Standard

AS/NZS 2802: 2000, AS/NZS 1125:2001, AS/NZS 2802:2003

Application

Type 455 Flexible Screened Mining Cable is particularly suited for stacker-reclaimer applications and is ideal for reeling and trailing operations. It is used where two earth and one pilot cores are required, and is also suitable for various industrial applications.

Technical Specifications

Type 455 Flexible Screened Mining Cable With Two Earth And One Pilot Core
Type 455 Flexible Screened Mining Cable With Two Earth And One Pilot Core
No. Of Cores

NOMINAL CONDUCTOR

AREA

mm²

THICKNESS OF

INSULATION

mm

CORE SCREEN

SIZE

mm

AREA OF

SCREEN

mm²

NOMINAL THICKNESS

OF SHEATH

mm

NOMINAL

DIAMETER

mm

NOMINAL

WEIGHT

kg/km

3+2+1 16 2.2 128/0.25 6.3 4.5 42.8 266
3+2+1 25 2.2 118/0.3 8.3 4.8 46.9 338
3+2+1 35 2.2 127/0.3 9 5.1 50.4 392
3+2+1 50 2.4 141/0.3 10 5.6 55.7 487
3+2+1 70 2.4 117/0.4 14.7 6 61.3 637
3+2+1 95 2.4 123/0.4 15.5 6.3 64.5 734
3+2+1 120 2.4 135/0.4 17 6.4 69.2 867
3+2+1 150 2.4 144/0.4 18.1 6.6 73.5 1022
3+2+1 185 2.4 144/0.4 26.7 6.7 78.3 1175
3+2+1 240 2.4 156/0.5 28.3 6.9 84.7 1741
3+2+1 16 3 118/0.3 8.3 5 47.7 317
3+2+1 25 3 129/0.3 9.1 5.2 51.3 382
3+2+1 35 3 139/0.3 9.8 5.5 54.8 443
3+2+1 50 3 149/0.3 10.5 5.9 58.9 534
3+2+1 70 3 123/0.4 15.5 6.3 64.3 682
3+2+1 95 3 130/0.4 16.3 6.4 67.1 771
3+2+1 120 3 141/0.4 17.7 6.5 71.9 912
3+2+1 150 3 144/0.4 18.1 6.6 76.2 1073
3+2+1 185 3 144/0.4 18.1 6.8 81 1222
3+2+1 240 3 144/0.5 27.7 7 87.5 1592
3+2+1 25 5 120/0.4 15.1 6.3 62.8 542
3+2+1 35 5 127/0.4 16 6.4 65.8 601
3+2+1 50 5 135/0.4 17 6.5 69.4 692
3+2+1 70 5 144/0.4 18.1 6.6 73.9 826
3+2+1 95 5 144/0.4 18.1 6.7 76.7 926
3+2+1 120 5 144/0.5 18.1 6.9 81.8 1082
3+2+1 150 5 139/0.5 27.3 7 86.2 1263

Quality Control

Type 455 Flexible Screened Mining Cable With Two Earth And One Pilot Core
Raw Material Test

Raw Material Test

NPC has always chosen raw material suppliers who have a good reputation, possess stable supply capabilities and have passed international quality system certifications (such as ISO 9001). And establish a long-term cooperative relationship with it, forming a stable and reliable raw material supply chain.
We will ensure that all raw materials are subject to strict inspection procedures upon entry to the factory, and can only be stored in the warehouse after they have been confirmed to meet the standards.

Process inspection

Process inspection

NPC has strict quality control procedures for each process in the cable production process.
Process documents: Develop detailed process flow and operation instructions to clarify the operating specifications and quality standards of each process.
Equipment calibration: Regularly calibrate key equipment such as wire drawing machines, stranding machines, extruders, and diameter gauges to ensure that the accuracy meets the requirements.
First piece confirmation: Before each batch of production, the first piece is trial-produced to confirm that the process parameters, product dimensions, electrical performance, etc. meet the standards before mass production can be carried out.

Finished Product

Finished Product

Inspectors conduct ex-factory inspections on cables according to relevant standards and corresponding product inspection specifications to ensure that each ex-factory product complies with the process regulations.

Application

Type 455 Flexible Screened Mining Cable is particularly suited for stacker-reclaimer applications and is ideal for reeling and trailing operations. It is used where two earth and one pilot cores are required, and is also suitable for various industrial applications.

Technical Advantages

● 30+ years of manufacturing experience
● ISO and UL certified production
● Customized cable and transformer solutions

Product Packaging

Wires and Cables packaging (1)
Wires and Cables packaging (1)
Wires and Cables packaging (2)
Wires and Cables packaging (2)
Wires and Cables packaging (3)
Wires and Cables packaging (3)
Wires and Cables packaging (4)
Wires and Cables packaging (4)
Wires and Cables packaging (5)
Wires and Cables packaging (5)
Wires and Cables packaging (6)
Wires and Cables packaging (6)
Wires and Cables packaging (7)
Wires and Cables packaging (7)
Wires and Cables packaging (8)
Wires and Cables packaging (8)

Related Products

FAQ From Customers

What are the advantages of power cables and overhead lines?
(1) Reliable operation, because it is installed in a hidden place such as underground, it is less damaged by external forces, has less chance of failure, and the power supply is safe, and it will not cause harm to people;
(2) The maintenance workload is small and frequent inspections are not required;
(3) No need to erect towers;
(4) Help improve power factor.
Which aspects should be considered when choosing the cross section of a power cable?
(1) The long-term allowable working current of the cable;
(2) Thermal stability once short circuited;
(3) The voltage drop on the line cannot exceed the allowable working range.
What are the measures for cable fire prevention?
(1) Use flame-retardant cables;
(2) Use fireproof cable tray;
(3) Use fireproof paint;
(4) Fire partition walls and fire baffles are installed at cable tunnels, mezzanine exits, etc.;
(5) Overhead cables should avoid oil pipelines and explosion-proof doors, otherwise local pipes or heat insulation and fire prevention measures should be taken.
What should be paid attention to during the transportation and handling of cables?
(1) During transportation, loading and unloading, cables and cable reels should not be damaged. It is strictly forbidden to push the cable reels directly from the vehicle. Generally, cables should not be transported and stored flat.
(2) Before transporting or rolling the cable reel, ensure that the cable reel is firm, the cable is wound tightly, the oil pipe between the oil-filled cable and the pressure oil tank should be fixed without damage, the pressure oil tank should be firm, and the pressure indication should meet the requirements.
What inspections should be carried out for the acceptance of cable lines?
(1) The cable specifications should meet the regulations, the arrangement should be neat, no damage, and the signs should be complete, correct and clear;
(2) The fixed bending radius of the cable, the related distance and the wiring of the metal sheath of the single-core power cable should meet the requirements;
(3) The cable terminal and the middle head should not leak oil, and the installation should be firm. The oil pressure of the oil-filled cable and the meter setting should meet the requirements;
(4) Good grounding;
(5) The color of the cable terminal is correct, and the metal parts such as the bracket are completely painted;
(6) There should be no debris in the cable trench, tunnel, and bridge, and the cover should be complete.

Welcome your inquiry

Honesty, Integrity, Frugality, Activeness and Passion