x
Type 455 Flexible Screened Mining Cable with two earth and one pilot core
Type 455 Flexible Screened Mining Cable with two earth and one pilot core

Type 455 Flexible Screened Mining Cable With Two Earth And One Pilot Core

The Type 455 Flexible Screened Mining Cable With Two Earth And One Pilot Core is an extra-heavy-duty flexible cable designed for the most severe underground mining operations requiring enhanced electrical safety. It features finely stranded tinned copper conductors (class 5) for exceptional flexibility and corrosion resistance, EPR insulation for high dielectric strength and 90°C continuous rating, tinned copper braid screen for effective EMI protection and grounding, two dedicated earth cores for redundant grounding and increased safety, one pilot core for earth continuity monitoring and machine interlock protection, and an extra-heavy-duty flame-retardant rubber outer sheath resistant to oil, abrasion, tearing, crushing, impact, and chemicals. Compliant with AS/NZS 2802 and mining safety standards, it supports very high tensile loads, frequent reeling/drag, tight bending radii, and reliable performance in wet, dusty, and hazardous conditions. The Type 455 is ideal for high-power trailing applications in coal and metalliferous mines, powering longwall shearers, continuous miners, face conveyors, shuttle cars, and critical mobile equipment with dual earth redundancy and pilot monitoring for maximum safety.
Voltage Rating Type 455.3 - 3.3kV
Type 455.6 - 6.6kV
Type 455.11 - 11kV
Temperature Rating -25°C to +90°C
Construction
Technical Specifications
Quality Control
Application

Construction

Type 455 Flexible Screened Mining Cable with two earth and one pilot core Constrution
Type 455 Flexible Screened Mining Cable With Two Earth And One Pilot Core

Conductor

Tinned anneaIed copper wires

Insulation

EPR (Ethylene Propylene Rubber) type XR-EP-90

Conductor Screen

Semi-conductive tape + thermosetting compound

Insulation Screen

Semi-conductive thermosetting compound

Cable Assembly

Three screened power, two earth and one pilot core laid up with right hand direction on the rubber centre filler

Screen

Tinned copper/polyamide braid

Inner Sheath

Semi-conductive thermosetting compound

Armour

Polyamide yarns

Outer Sheath

HD-CSP (Heavy-duty Chlorosulphonated Polyethylene) - extra heavy duty, oil resistant and flame retardant

Sheath Colour

Black

Manufacturer Standard

AS/NZS 2802: 2000, AS/NZS 1125:2001, AS/NZS 2802:2003

Application

Type 455 Flexible Screened Mining Cable is particularly suited for stacker-reclaimer applications and is ideal for reeling and trailing operations. It is used where two earth and one pilot cores are required, and is also suitable for various industrial applications.

Technical Specifications

Type 455 Flexible Screened Mining Cable With Two Earth And One Pilot Core
Type 455 Flexible Screened Mining Cable With Two Earth And One Pilot Core
No. Of Cores

NOMINAL CONDUCTOR

AREA

mm²

THICKNESS OF

INSULATION

mm

CORE SCREEN

SIZE

mm

AREA OF

SCREEN

mm²

NOMINAL THICKNESS

OF SHEATH

mm

NOMINAL

DIAMETER

mm

NOMINAL

WEIGHT

kg/km

3+2+1 16 2.2 128/0.25 6.3 4.5 42.8 266
3+2+1 25 2.2 118/0.3 8.3 4.8 46.9 338
3+2+1 35 2.2 127/0.3 9 5.1 50.4 392
3+2+1 50 2.4 141/0.3 10 5.6 55.7 487
3+2+1 70 2.4 117/0.4 14.7 6 61.3 637
3+2+1 95 2.4 123/0.4 15.5 6.3 64.5 734
3+2+1 120 2.4 135/0.4 17 6.4 69.2 867
3+2+1 150 2.4 144/0.4 18.1 6.6 73.5 1022
3+2+1 185 2.4 144/0.4 26.7 6.7 78.3 1175
3+2+1 240 2.4 156/0.5 28.3 6.9 84.7 1741
3+2+1 16 3 118/0.3 8.3 5 47.7 317
3+2+1 25 3 129/0.3 9.1 5.2 51.3 382
3+2+1 35 3 139/0.3 9.8 5.5 54.8 443
3+2+1 50 3 149/0.3 10.5 5.9 58.9 534
3+2+1 70 3 123/0.4 15.5 6.3 64.3 682
3+2+1 95 3 130/0.4 16.3 6.4 67.1 771
3+2+1 120 3 141/0.4 17.7 6.5 71.9 912
3+2+1 150 3 144/0.4 18.1 6.6 76.2 1073
3+2+1 185 3 144/0.4 18.1 6.8 81 1222
3+2+1 240 3 144/0.5 27.7 7 87.5 1592
3+2+1 25 5 120/0.4 15.1 6.3 62.8 542
3+2+1 35 5 127/0.4 16 6.4 65.8 601
3+2+1 50 5 135/0.4 17 6.5 69.4 692
3+2+1 70 5 144/0.4 18.1 6.6 73.9 826
3+2+1 95 5 144/0.4 18.1 6.7 76.7 926
3+2+1 120 5 144/0.5 18.1 6.9 81.8 1082
3+2+1 150 5 139/0.5 27.3 7 86.2 1263

Quality Control

Type 455 Flexible Screened Mining Cable With Two Earth And One Pilot Core
Raw Material Test

Raw Material Test

Raw Material Test for Type 455 Flexible Screened Mining Cable With Two Earth And One Pilot Core ensures extreme mining-grade durability and safety redundancy. The detailed process includes: Supplier Certification Review: Verify class 5 tinned copper conductors meet AS/NZS 1125 or IEC 60228 for purity (>99.9% Cu), stranding, and tin coating; EPR insulation, pilot/earth cores, and rubber sheath compounds certified to AS/NZS 2802 for flame retardancy and mechanical properties. Conductor Analysis: Test tinned copper (phase/earth/pilot) for tensile strength (>200 MPa), elongation (>20%), conductivity (≥97% IACS), and tin uniformity to ensure corrosion resistance in wet mining conditions. Insulation Testing: EPR insulation evaluated for tensile (>6.5 MPa), elongation (>300%), dielectric strength (>20 kV/mm), thermal aging (100°C/168h).

Process inspection

Process inspection

Process Inspection during manufacturing of Type 455 Flexible Screened Mining Cable With Two Earth And One Pilot Core maintains mining safety and extra-heavy-duty consistency. Steps include: Conductor & Core Stranding: Monitor class 5 stranding of phase, two earth, and one central pilot conductors for uniform lay length, compactness, and no loose strands. Insulation Extrusion: Apply EPR insulation at controlled thickness; inline diameter scanners, eccentricity monitors, and spark testers detect voids or defects. Screening Application: Braid tinned copper with precise coverage (>80%) and tension control; real-time monitoring of braid angle and optical coverage for effective EMI protection. Outer Sheath Extrusion: Extrude extra-heavy-duty rubber sheath; continuous checks on thickness, surface finish, adhesion, and enhanced mechanical properties. 

Finished Product

Finished Product

Finished Product Test confirms the Type 455 Flexible Screened Mining Cable With Two Earth And One Pilot Core meets mining standards before shipment. The procedure includes: Visual & Dimensional Inspection: Examine full length for defects, uniformity, markings, and measure outer diameter/weight per meter. Electrical Tests: Conductor DC resistance, insulation resistance (>1000 MΩ·km), high-voltage withstand (e.g., 11kV for 3.6/6kV class/5 min), partial discharge, screen continuity, and pilot/dual earth core functionality per AS/NZS 2802/IEC. Mechanical Evaluation: Bending radius (6–8× OD), tensile strength, crush resistance, abrasion/tear tests, and dynamic flexing to simulate mining reeling. Sheath & Insulation Performance: Oil immersion, flame retardancy (AS/NZS 1660.5.1 or IEC 60332), thermal aging, and moisture resistance verified. 

Application

The Type 455 Flexible Screened Mining Cable With Two Earth And One Pilot Core excels in severe underground coal and metalliferous mining for high-voltage trailing/reeling power to longwall shearers, continuous miners, face conveyors, shuttle cars, and heavy equipment requiring screened, flame-retardant cable with dual earth cores and pilot core for enhanced grounding safety and monitoring.

Technical Advantages

● 30+ years of manufacturing experience
● ISO and UL certified production
● Customized cable and transformer solutions

Product Packaging

Wires and Cables packaging (1)
Wires and Cables packaging (1)
Wires and Cables packaging (2)
Wires and Cables packaging (2)
Wires and Cables packaging (3)
Wires and Cables packaging (3)
Wires and Cables packaging (4)
Wires and Cables packaging (4)
Wires and Cables packaging (5)
Wires and Cables packaging (5)
Wires and Cables packaging (6)
Wires and Cables packaging (6)
Wires and Cables packaging (7)
Wires and Cables packaging (7)
Wires and Cables packaging (8)
Wires and Cables packaging (8)

Related Products

FAQ From Customers

What are the advantages of power cables and overhead lines?
(1) Reliable operation, because it is installed in a hidden place such as underground, it is less damaged by external forces, has less chance of failure, and the power supply is safe, and it will not cause harm to people;
(2) The maintenance workload is small and frequent inspections are not required;
(3) No need to erect towers;
(4) Help improve power factor.
Which aspects should be considered when choosing the cross section of a power cable?
(1) The long-term allowable working current of the cable;
(2) Thermal stability once short circuited;
(3) The voltage drop on the line cannot exceed the allowable working range.
What are the measures for cable fire prevention?
(1) Use flame-retardant cables;
(2) Use fireproof cable tray;
(3) Use fireproof paint;
(4) Fire partition walls and fire baffles are installed at cable tunnels, mezzanine exits, etc.;
(5) Overhead cables should avoid oil pipelines and explosion-proof doors, otherwise local pipes or heat insulation and fire prevention measures should be taken.
What should be paid attention to during the transportation and handling of cables?
(1) During transportation, loading and unloading, cables and cable reels should not be damaged. It is strictly forbidden to push the cable reels directly from the vehicle. Generally, cables should not be transported and stored flat.
(2) Before transporting or rolling the cable reel, ensure that the cable reel is firm, the cable is wound tightly, the oil pipe between the oil-filled cable and the pressure oil tank should be fixed without damage, the pressure oil tank should be firm, and the pressure indication should meet the requirements.
What inspections should be carried out for the acceptance of cable lines?
(1) The cable specifications should meet the regulations, the arrangement should be neat, no damage, and the signs should be complete, correct and clear;
(2) The fixed bending radius of the cable, the related distance and the wiring of the metal sheath of the single-core power cable should meet the requirements;
(3) The cable terminal and the middle head should not leak oil, and the installation should be firm. The oil pressure of the oil-filled cable and the meter setting should meet the requirements;
(4) Good grounding;
(5) The color of the cable terminal is correct, and the metal parts such as the bracket are completely painted;
(6) There should be no debris in the cable trench, tunnel, and bridge, and the cover should be complete.

Welcome your inquiry

Honesty, Integrity, Frugality, Activeness and Passion