x
6 Pekingese Aluminum Conductor Duplex Overhead Service Drop Cable
6 Pekingese Aluminum Conductor Duplex Overhead Service Drop Cable

6 Pekingese Aluminum Conductor Duplex Overhead Service Drop Cable

The 6 Pekingese Aluminum Conductor Duplex Overhead Service Drop Cable is designed for safe and efficient secondary overhead power distribution from utility lines to residential and light commercial service entrances. The duplex configuration consists of two concentrically stranded aluminum conductors, typically serving as a phase conductor and a neutral messenger, providing reliable electrical transmission and mechanical support. The No. 6 Pekingese conductor size is well suited for short-span service drop installations, offering stable current-carrying capacity with controlled sag and adequate tensile strength. Aluminum construction ensures lightweight handling, excellent corrosion resistance, and simplified installation in outdoor environments. Manufactured in accordance with ASTM standards and utility specifications, the 6 Pekingese Aluminum Conductor Duplex Overhead Service Drop Cable delivers uniform stranding, consistent conductivity, and dependable long-term performance. It is widely selected by utilities and contractors seeking a cost-effective, durable solution for overhead service drop applications.
Construction
Technical Specifications
Quality Control
Application

Construction

6 Pekingese Aluminum Conductor Duplex Overhead Service Drop Cable Constrution
6 Pekingese Aluminum Conductor Duplex Overhead Service Drop Cable

Standard

• ASTM B-230 Aluminum Wire, 1350-H19 for Electrical Purposes.
• ASTM B-231 Aluminum Conductors, Concentric-Lay-Stranded.
• ASTM B-232 Aluminum Conductors, Concentric-Lay-Stranded, Coated Steel Reinforced (ACSR).
• ASTM B-399 Concentric-Lay-Stranded 6201-T81 Aluminum Alloy Conductors.
• ICEA S-76-474-Neutral-supported Power Cable Assemblies With Weather-Resistant Extruded Insulation Rated 600Volts

Phase Conductor

Stranded compacted circular aluminum

Insulation

XLPE(UV-resistant)

Messenger Conductor

AAC/AAAC/ACSR

Application

Aluminum Conductor Duplex Overhead Service Drop Cable is designed for use to supply 120-volt aerial service for temporary service at construction sites, outdoor or street lighting. For service at 600 volts or lower at a conductor temperature of 90°C maximum.

Application Type

6 pekingese aluminium overhead cables, 6 pekingese overhead aluminum wire, 6 pekingese two conductor cable, 6 pekingese 2 conductor power cable, 6 pekingese two conductor, 6 pekingese aluminum drop, 6 pekingese overhead service drop conductors, 6 pekingese overhead service conductors.

Technical Specifications

6 Pekingese Aluminum Conductor Duplex Overhead Service Drop Cable
6 Pekingese Aluminum Conductor Duplex Overhead Service Drop Cable
Rated voltage kV 0.6/1
Test voltage Veff kV/Hz 4/50
Laying temperature °C min. -5
Operating temperature °C -30 ~ +90
Conductor temperature °C max. +90
Short-circuit temperature °C/s max. +250 /5
Bending radius (min.) mm 20 × Ø of cable

Quality Control

6 Pekingese Aluminum Conductor Duplex Overhead Service Drop Cable
6 Pekingese Aluminum Conductor Duplex Overhead Service Drop Cable Material Test

Raw Material Test

The Raw Material Test is the first quality control step for the 6 Pekingese Aluminum Conductor Duplex Overhead Service Drop Cable. Incoming aluminum rods are tested for chemical composition, electrical conductivity, tensile strength, and elongation to ensure compliance with specification requirements. Surface quality and dimensional accuracy are inspected to prevent defects during wire drawing. Each batch of raw material is clearly identified and traceable throughout the production process. Only aluminum materials that meet defined electrical and mechanical standards are approved for manufacturing, ensuring the finished 6 Pekingese Aluminum Conductor Duplex Overhead Service Drop Cable delivers stable performance, durability, and long service life.

6 Pekingese Aluminum Conductor Duplex Overhead Service Drop Cable Process inspection

Process inspection

Process Inspection ensures controlled manufacturing quality of the 6 Pekingese Aluminum Conductor Duplex Overhead Service Drop Cable. During wire drawing, conductor diameter, surface finish, and mechanical properties are continuously monitored. In the stranding process, precise lay length and balanced tension are applied to achieve proper flexibility and conductor alignment. In-process inspections verify strand compactness, roundness, and structural integrity. These systematic controls ensure the cable meets design specifications for electrical reliability and mechanical durability.

6 Pekingese Aluminum Conductor Duplex Overhead Service Drop Cable Finished Product

Finished Product

The Finished Product Test confirms final compliance of the 6 Pekingese Aluminum Conductor Duplex Overhead Service Drop Cable. Electrical resistance testing verifies conductivity performance, while tensile strength and elongation tests confirm mechanical integrity. Additional inspections include conductor diameter measurement, visual surface examination, marking verification, and packaging checks. These tests ensure the cable is safe, compliant, and ready for installation.

Application

Used for overhead service drop connections supplying power from utility distribution lines to residential homes, small commercial buildings, and light industrial facilities.

Technical Advantages

● 30+ years of manufacturing experience
● ISO and UL certified production
● Customized cable and transformer solutions

Product Packaging

Wires and Cables packaging (1)
Wires and Cables packaging (1)
Wires and Cables packaging (2)
Wires and Cables packaging (2)
Wires and Cables packaging (3)
Wires and Cables packaging (3)
Wires and Cables packaging (4)
Wires and Cables packaging (4)
Wires and Cables packaging (5)
Wires and Cables packaging (5)
Wires and Cables packaging (6)
Wires and Cables packaging (6)
Wires and Cables packaging (7)
Wires and Cables packaging (7)
Wires and Cables packaging (8)
Wires and Cables packaging (8)

Related Products

FAQ From Customers

What are the advantages of power cables and overhead lines?
(1) Reliable operation, because it is installed in a hidden place such as underground, it is less damaged by external forces, has less chance of failure, and the power supply is safe, and it will not cause harm to people;
(2) The maintenance workload is small and frequent inspections are not required;
(3) No need to erect towers;
(4) Help improve power factor.
Which aspects should be considered when choosing the cross section of a power cable?
(1) The long-term allowable working current of the cable;
(2) Thermal stability once short circuited;
(3) The voltage drop on the line cannot exceed the allowable working range.
What are the measures for cable fire prevention?
(1) Use flame-retardant cables;
(2) Use fireproof cable tray;
(3) Use fireproof paint;
(4) Fire partition walls and fire baffles are installed at cable tunnels, mezzanine exits, etc.;
(5) Overhead cables should avoid oil pipelines and explosion-proof doors, otherwise local pipes or heat insulation and fire prevention measures should be taken.
What should be paid attention to during the transportation and handling of cables?
(1) During transportation, loading and unloading, cables and cable reels should not be damaged. It is strictly forbidden to push the cable reels directly from the vehicle. Generally, cables should not be transported and stored flat.
(2) Before transporting or rolling the cable reel, ensure that the cable reel is firm, the cable is wound tightly, the oil pipe between the oil-filled cable and the pressure oil tank should be fixed without damage, the pressure oil tank should be firm, and the pressure indication should meet the requirements.
What inspections should be carried out for the acceptance of cable lines?
(1) The cable specifications should meet the regulations, the arrangement should be neat, no damage, and the signs should be complete, correct and clear;
(2) The fixed bending radius of the cable, the related distance and the wiring of the metal sheath of the single-core power cable should meet the requirements;
(3) The cable terminal and the middle head should not leak oil, and the installation should be firm. The oil pressure of the oil-filled cable and the meter setting should meet the requirements;
(4) Good grounding;
(5) The color of the cable terminal is correct, and the metal parts such as the bracket are completely painted;
(6) There should be no debris in the cable trench, tunnel, and bridge, and the cover should be complete.

Welcome your inquiry