x
(N)TSCGECEWOU 3.6/6kV and 6/10kV ATB Cable
(N)TSCGECEWOU 3.6/6kV and 6/10kV ATB Cable

(N)TSCGECEWOU 3.6/6kV and 6/10kV ATB Cable

The (N)TSCGECEWOU 3.6/6kV and 6/10kV ATB cable is a flexible medium voltage power cable designed according to VDE standards for heavy-duty applications in mining, tunneling, and dynamic machinery such as tunnel boring machines (ATB). It features Class 5 tinned copper conductors, EPR insulation, halogen-free flame-retardant sheath, and an anti-torsion braid for stability in reeling and trailing operations. With excellent mechanical strength, oil resistance, and abrasion resistance, this cable ensures reliable performance in harsh industrial environments, both indoors and outdoors.
Voltage Rating Uo/U 3.6/6kV | 6/10kV
Test Voltage 3.6/6kV: 11kV
6/10kV: 17kV
Temperature Rating Fixed: -25°C to +80°C
Flexed: -40°C to +80°C
Minimum Bending Radius Fixed: 6 x overall diameter
Flexed: 10 x overall diameter
Maximum Short Circuit Temperature +250°C
Maximum Torsional Stress ±25°/m
Construction
Technical Specifications
Quality Control
Application

Construction

(N)TSCGECEWOU 3.6/6kV and 6/10kV ATB Cable Constrution
(N)TSCGECEWOU 3.6/6kV and 6/10kV ATB Cable

Phase Conductor

Class 5 tinned copper conductor

Insulation

Rubber compound

Protective Earth Conductor

Individual copper wire braid

Central Filler

Rubber compound on a polyester textile support

Inner Sheath

Abrasion-resistant rubber compound

Anti-Torsion Braid

Polyester braid between the inner and outer sheath

Outer Sheath

Abrasion-resistant rubber compound

Sheath Colour

Yellow

Manufacturer Standard

VDE 0250 Part 813, VDE 0295, EN 60228

Flame Retardant

IEC/EN 60332-1-2

Semi-Conductive Layers

Semi-conductive tape over the conductor and inner and outer
Semi-conductive rubber layer on the insulation

Application

(N)TSCGECEWOU 3.6/6kV and 6/10kV ATB cable is a flexible medium voltage cable with screened conductors, EPR insulation, and a robust, flame-retardant, halogen-free sheath. It is specially designed for dynamic applications such as tunnel boring machines (ATB), offering excellent mechanical strength, oil resistance, and outdoor durability.

Technical Specifications

(N)TSCGECEWOU 3.6/6kV and 6/10kV ATB Cable
(N)TSCGECEWOU ATB Cable 3.6/6kV
(N)TSCGECEWOU ATB Cable 6/10kV

No. Of Cores
(PHASE+EARH)

Nominal Cross Sectional Area
mm²

CONDUCTOR

DIAMETER

MINIMUM OVERALL

DIAMETER

MAXIMUM OVERALL

DIAMETER

MAXIMUM

TENSILE LOAD

NOMINAL

WEIGHT

Phase 

Conductor

Earth

Conductor

mm mm mm N kg/km
3+3 25 25/3E 6.8 43.4 45.1 1125 2850
3+3 35 25/3E 7.8 45 46.7 1575 3200
3+3 50 25/3E 9.4 48.1 49.8 2250 3850
3+3 70 35/3E 11.2 53.7 55.5 3150 4980
3+3 95 50/3E 12.7 58.4 60.2 4275 6200
3+3 120 70/3E 14.4 62.9 65.2 5400 7550
3+3 150 70/3E 16.3 69.3 71.7 6750 9090

No. Of Cores
(PHASE+EARH)

Nominal Cross Sectional Area
mm²

CONDUCTOR

DIAMETER

MINIMUM OVERALL

DIAMETER

MAXIMUM OVERALL

DIAMETER

MAXIMUM

TENSILE LOAD

NOMINAL

WEIGHT

Phase

Conductor

Earth

Conductor

mm mm mm N kg/km
3+3 25 25/3E 6.8 43.4 45.7 1125 2890
3+3 35 25/3E 7.8 45 47.3 1575 3240
3+3 50 25/3E 9.4 48.1 50.4 2250 3890
3+3 70 35/3E 11.2 53.7 56.1 3150 5020
3+3 95 50/3E 12.7 58.4 60.8 4275 6240
3+3 120 70/3E 14.4 62.9 65.9 5400 7620
3+3 150 70/3E 16.3 69.3 72.4 6750 9130

Quality Control

(N)TSCGECEWOU 3.6/6kV and 6/10kV ATB Cable
(N)TSCGECEWOU 3.6/6kV and 6/10kV ATB Cable Raw Material Test

Raw Material Test

NPC has always chosen raw material suppliers who have a good reputation, possess stable supply capabilities and have passed international quality system certifications (such as ISO 9001). And establish a long-term cooperative relationship with it, forming a stable and reliable raw material supply chain.
We will ensure that all raw materials are subject to strict inspection procedures upon entry to the factory, and can only be stored in the warehouse after they have been confirmed to meet the standards.

(N)TSCGECEWOU 3.6/6kV and 6/10kV ATB Cable Process inspection

Process inspection

NPC has strict quality control procedures for each process in the cable production process.
Process documents: Develop detailed process flow and operation instructions to clarify the operating specifications and quality standards of each process.
Equipment calibration: Regularly calibrate key equipment such as wire drawing machines, stranding machines, extruders, and diameter gauges to ensure that the accuracy meets the requirements.
First piece confirmation: Before each batch of production, the first piece is trial-produced to confirm that the process parameters, product dimensions, electrical performance, etc. meet the standards before mass production can be carried out.

(N)TSCGECEWOU 3.6/6kV and 6/10kV ATB Cable Finished Product

Finished Product

Inspectors conduct ex-factory inspections on cables according to relevant standards and corresponding product inspection specifications to ensure that each ex-factory product complies with the process regulations.

Application

(N)TSCGECEWOU 3.6/6kV and 6/10kV ATB cable is a flexible medium voltage cable with screened conductors, EPR insulation, and a robust, flame-retardant, halogen-free sheath. It is specially designed for dynamic applications such as tunnel boring machines (ATB), offering excellent mechanical strength, oil resistance, and outdoor durability.

Technical Advantages

● 30+ years of manufacturing experience
● ISO and UL certified production
● Customized cable and transformer solutions

Product Packaging

Wires and Cables packaging (1)
Wires and Cables packaging (1)
Wires and Cables packaging (2)
Wires and Cables packaging (2)
Wires and Cables packaging (3)
Wires and Cables packaging (3)
Wires and Cables packaging (4)
Wires and Cables packaging (4)
Wires and Cables packaging (5)
Wires and Cables packaging (5)
Wires and Cables packaging (6)
Wires and Cables packaging (6)
Wires and Cables packaging (7)
Wires and Cables packaging (7)
Wires and Cables packaging (8)
Wires and Cables packaging (8)

Related Products

FAQ From Customers

What are the advantages of power cables and overhead lines?
(1) Reliable operation, because it is installed in a hidden place such as underground, it is less damaged by external forces, has less chance of failure, and the power supply is safe, and it will not cause harm to people;
(2) The maintenance workload is small and frequent inspections are not required;
(3) No need to erect towers;
(4) Help improve power factor.
Which aspects should be considered when choosing the cross section of a power cable?
(1) The long-term allowable working current of the cable;
(2) Thermal stability once short circuited;
(3) The voltage drop on the line cannot exceed the allowable working range.
What are the measures for cable fire prevention?
(1) Use flame-retardant cables;
(2) Use fireproof cable tray;
(3) Use fireproof paint;
(4) Fire partition walls and fire baffles are installed at cable tunnels, mezzanine exits, etc.;
(5) Overhead cables should avoid oil pipelines and explosion-proof doors, otherwise local pipes or heat insulation and fire prevention measures should be taken.
What should be paid attention to during the transportation and handling of cables?
(1) During transportation, loading and unloading, cables and cable reels should not be damaged. It is strictly forbidden to push the cable reels directly from the vehicle. Generally, cables should not be transported and stored flat.
(2) Before transporting or rolling the cable reel, ensure that the cable reel is firm, the cable is wound tightly, the oil pipe between the oil-filled cable and the pressure oil tank should be fixed without damage, the pressure oil tank should be firm, and the pressure indication should meet the requirements.
What inspections should be carried out for the acceptance of cable lines?
(1) The cable specifications should meet the regulations, the arrangement should be neat, no damage, and the signs should be complete, correct and clear;
(2) The fixed bending radius of the cable, the related distance and the wiring of the metal sheath of the single-core power cable should meet the requirements;
(3) The cable terminal and the middle head should not leak oil, and the installation should be firm. The oil pressure of the oil-filled cable and the meter setting should meet the requirements;
(4) Good grounding;
(5) The color of the cable terminal is correct, and the metal parts such as the bracket are completely painted;
(6) There should be no debris in the cable trench, tunnel, and bridge, and the cover should be complete.

Welcome your inquiry

Honesty, Integrity, Frugality, Activeness and Passion