x
USEB-90 AA8000 Concentric Underground Service Cable 600/1000V
USEB-90 AA8000 Concentric Underground Service Cable 600/1000V
USEB-90 AA8000 Concentric Underground Service Cable 600/1000V
USEB-90 AA8000 Concentric Underground Service Cable 600/1000V
USEB-90 AA8000 Concentric Underground Service Cable 600/1000V
USEB-90 AA8000 Concentric Underground Service Cable 600/1000V
USEB-90 AA8000 Concentric Underground Service Cable 600/1000V
USEB-90 AA8000 Concentric Underground Service Cable 600/1000V

USEB-90 AA8000 Concentric Underground Service Cable 600/1000V

The USEB-90 Underground Concentric Service Cable is an advanced low-voltage cable engineered for underground service entrance and secondary distribution systems. It utilizes compact AA8000 aluminum alloy phase conductors with XLPE insulation and a concentrically arranged neutral layer, protected by a durable polyethylene sheath. This design offers superior flexibility, high current-carrying capacity, excellent mechanical protection, and outstanding resistance to moisture and corrosion. Suitable for direct burial without additional conduit, the USEB-90 Underground Concentric Service Cable simplifies installation while ensuring long-term reliability. It meets international performance requirements and undergoes extensive quality testing to deliver consistent electrical performance and durability in demanding underground environments.
Voltage Rating 600V / 1000V
Insulation XLPE (Cross-linked Polyethylene)
Neutral Concentric aluminum alloy
Construction
Technical Specifications
Quality Control
Application

Construction

USEB-90 AA8000 Concentric Underground Service Cable 600/1000V
USEB-90 AA8000 Concentric Underground Service Cable 600/1000V Construction

Key Product Features

AA8000 alloy conductors for enhanced strength and flexibility
XLPE insulation for superior dielectric performance
Concentric neutral for balanced electrical characteristics
Robust polyethylene sheath for moisture and abrasion resistance
Optimized for direct burial installations

Conductor

AA8000 Aluminum Alloy

Insulation

XLPE or PVC or PE or customized

Neutral Conductor

Copper wire, Aluminum Wire, Aluminum Alloy Wire S8000

Installation

Direct burial

Technical Specifications

USEB-90 AA8000 Concentric Underground Service Cable 600/1000V
Circular Type Concentric Cables
Flat Type Concentric Cables
Size Phase Conductor XLPE  Insulation Neutral Conductor XLPE Sheath Approx.Weight
Structure O.D Thickness O.D Structure O.D Thickness O.D CU AL
AWG No./mm mm mm mm No./mm mm mm mm kg/km kg/km
2x8 7/1.23 3.69 1.14 5.97 25/0.65 7.27 1.14 9.84 202 97
2x10 7/0.98 2.94 1.14 5.22 25/0.52 6.26 1.14 8.83 141 74
Size Phase Conductor XLPE Insulation Inner
Sheath
Neutral  
Conductor
XLPE Sheath Approx.Weight
Structure O.D Thickness O.D Thickness Structure Thickness O.D CU AL
AWG No./mm mm mm mm mm No./mm mm mm kg/km kg/km
3x8 7/1.23 3.69 1.14 5.97 0.7 65/0.41 1.14 16.59x10.62 396 227
3x6 7/1.55 4.65 1.14 6.93 0.7 65/0.52 1.14 18.73x11.80 551 297
3x4 7/1.96 4.98 1.14 8.16 0.7 65/0.65 1.52 22.21x14.05 830 427
3x2 7/2.47 7.41 1.14 9.69 0.7 65/0.83 1.52 25.63x15.94 1233 587

Quality Control

USEB-90 AA8000 Concentric Underground Service Cable 600/1000V
Raw Material Test

Raw Material Test

Raw Material Test for the USEB-90 Underground Concentric Service Cable involves rigorous evaluation of AA8000 aluminum alloy rods and insulation compounds. Chemical analysis confirms exact alloy composition and high purity. Mechanical properties such as tensile strength, elongation, and hardness are tested to meet required specifications. XLPE and polyethylene materials undergo thermal stability, dielectric, and moisture resistance testing. Detailed surface and dimensional inspections identify any potential defects before processing. Only fully compliant raw materials are released for wire drawing and extrusion in the production of the USEB-90 Underground Concentric Service Cable. This comprehensive raw material validation establishes the foundation for superior flexibility, conductivity, mechanical strength, and long-term reliability in underground concentric cable applications.

 

Process inspection

Process inspection

Process Inspection throughout the manufacturing of the USEB-90 Underground Concentric Service Cable focuses on precision and consistency. Wire drawing is monitored to achieve exact diameters with continuous quality checks. During concentric stranding, automated tension and revolution controls ensure perfect configuration with accurate lay lengths. XLPE insulation and polyethylene sheath extrusion parameters are strictly controlled for uniform thickness and strong adhesion. Frequent in-line diameter measurements and visual inspections catch anomalies immediately. Environmental and process variables are logged to prevent contamination. Intermediate samples undergo resistance and mechanical spot testing. Any non-conformance prompts swift corrective measures. These detailed process controls protect the integrity and performance characteristics of the USEB-90 Underground Concentric Service Cable, resulting in a uniform, high-quality underground service cable.

 

Finished Product

Finished Product

Every completed reel of USEB-90 Underground Concentric Service Cable passes comprehensive Finished Product testing. Dimensional inspections verify the overall diameter and precise conductor alignment. Electrical resistance measurements and high-voltage tests confirm compliance with standards. Mechanical testing validates tensile strength and elongation properties. Full visual examination ensures a smooth, defect-free surface with uniform sheath. All tests adhere strictly to applicable standards, with complete documentation and batch traceability maintained. Packaging and labeling are inspected for accuracy. Only the USEB-90 Underground Concentric Service Cable that meets every quality criterion receives final approval. This final assurance stage guarantees customers a premium concentric underground cable with proven flexibility, conductivity, and durability for reliable service entrance applications.

 

Application

Ideal for underground service entrance connections, residential and commercial direct burial from transformer to meter, secondary LV underground distribution, and underground networks requiring flexible, moisture-resistant, and durable low-voltage cables.

Technical Advantages

● 30+ years of manufacturing experience
● ISO and UL certified production
● Customized cable and transformer solutions

Product Packaging

Wires and Cables packaging (1)
Wires and Cables packaging (1)
Wires and Cables packaging (2)
Wires and Cables packaging (2)
Wires and Cables packaging (3)
Wires and Cables packaging (3)
Wires and Cables packaging (4)
Wires and Cables packaging (4)
Wires and Cables packaging (5)
Wires and Cables packaging (5)
Wires and Cables packaging (6)
Wires and Cables packaging (6)
Wires and Cables packaging (7)
Wires and Cables packaging (7)
Wires and Cables packaging (8)
Wires and Cables packaging (8)

Related Products

FAQ From Customers

What are the advantages of power cables and overhead lines?
(1) Reliable operation, because it is installed in a hidden place such as underground, it is less damaged by external forces, has less chance of failure, and the power supply is safe, and it will not cause harm to people;
(2) The maintenance workload is small and frequent inspections are not required;
(3) No need to erect towers;
(4) Help improve power factor.
Which aspects should be considered when choosing the cross section of a power cable?
(1) The long-term allowable working current of the cable;
(2) Thermal stability once short circuited;
(3) The voltage drop on the line cannot exceed the allowable working range.
What are the measures for cable fire prevention?
(1) Use flame-retardant cables;
(2) Use fireproof cable tray;
(3) Use fireproof paint;
(4) Fire partition walls and fire baffles are installed at cable tunnels, mezzanine exits, etc.;
(5) Overhead cables should avoid oil pipelines and explosion-proof doors, otherwise local pipes or heat insulation and fire prevention measures should be taken.
What should be paid attention to during the transportation and handling of cables?
(1) During transportation, loading and unloading, cables and cable reels should not be damaged. It is strictly forbidden to push the cable reels directly from the vehicle. Generally, cables should not be transported and stored flat.
(2) Before transporting or rolling the cable reel, ensure that the cable reel is firm, the cable is wound tightly, the oil pipe between the oil-filled cable and the pressure oil tank should be fixed without damage, the pressure oil tank should be firm, and the pressure indication should meet the requirements.
What inspections should be carried out for the acceptance of cable lines?
(1) The cable specifications should meet the regulations, the arrangement should be neat, no damage, and the signs should be complete, correct and clear;
(2) The fixed bending radius of the cable, the related distance and the wiring of the metal sheath of the single-core power cable should meet the requirements;
(3) The cable terminal and the middle head should not leak oil, and the installation should be firm. The oil pressure of the oil-filled cable and the meter setting should meet the requirements;
(4) Good grounding;
(5) The color of the cable terminal is correct, and the metal parts such as the bracket are completely painted;
(6) There should be no debris in the cable trench, tunnel, and bridge, and the cover should be complete.

Welcome your inquiry

Honesty, Integrity, Frugality, Activeness and Passion