4 Hackney Aluminum Conductor Quadruplex Overhead Service Drop Cable
4 Hackney Aluminum Conductor Quadruplex Overhead Service Drop Cable

4 Hackney Aluminum Conductor Quadruplex Overhead Service Drop Cable

4 Hackney Quadruplex Service Drop Cable is a robust overhead cable for three-phase secondary power distribution with neutral. Featuring three 4 AWG aluminum phase conductors and one neutral messenger (7-strand) insulated with XLPE or PE and assembled in quadruplex configuration, it offers excellent mechanical strength and weather resistance. Compliant with ASTM B-230, B-231, ICEA S-76-474, and ANSI/ICEA standards, this cable supports 600V applications with superior UV, moisture, and abrasion protection. The self-supporting messenger reduces sag and simplifies installation over medium spans. The 4 Hackney Quadruplex Service Drop Cable ensures low power losses, high current capacity, and long service life in harsh outdoor conditions. Lightweight and flexible, it is widely used for three-phase service drops in residential subdivisions, commercial buildings, and rural areas requiring safe, cost-effective aerial connections from utility poles to service entrances.
Construction
Technical Specifications
Quality Control
Application

Construction

4 Hackney Aluminum Conductor Quadruplex Overhead Service Drop Cable Construction
4 Hackney Aluminum Conductor Quadruplex Overhead Service Drop Cable Construction

Standard

• ASTM B-230 Aluminum Wire, 1350-H19 for Electrical Purposes.
• ASTM B-231 Aluminum Conductors, Concentric-Lay-Stranded.
• ASTM B-232 Aluminum Conductors, Concentric-Lay-Stranded, Coated Steel Reinforced (ACSR).
• ASTM B-399 Concentric-Lay-Stranded 6201-T81 Aluminum Alloy Conductors.
• ICEA S-76-474-Neutral-supported Power Cable Assemblies With Weather-Resistant Extruded Insulation Rated 600Volts

Phase Conductor

Strand or Compressed 1350-H19 Series Aluminum Conductor.

Neutral(Messenger )Conductor

Bare ACSR messenger. Optional constructions include a messenger of AAC or 6201 alloy.

Insulation

Black Cross Linked Polyethylene (XLP) Insulation.

Application

4 hackney aluminum conductor quadruplex overhead service drop cable used to supply 3-phase power, usually from a pole mounted transformer, to the user's service head where connection to the service entrance cable is made. To be used at voltages of 600 volts phase to phase or less and at conductor temperatures not to exceed 75°C for polyethylene insulated conductors or 90°C for cross linked polyethylene (XLP) insulated conductors

Application Type

4 hackney aluminum quadruplex, 4 hackney overhead service drop, 4 hackney three phase cable, 4 hackney 3 phase cable, 4 hackney 3 phase power cable, 4 hackney 3 phase extension cord, 4 hackney 3 phase aluminum cable, 4 hackney 3 phase electrical cable, 4 hackney three phase power cable, 4 hackney quadruplex wire, 4 hackney quadruplex overhead wire, 4 hackney overhead service entrance cable.

Features

1. Ideal for overhead 3-phase service drops
2. Rated up to 600 volts, suitable for outdoor environments
3. XLP or PE insulation ensures high thermal performance and durability
4. Constructed to meet ASTM B-230, B-231, B-232, B-399, and ICEA S-76-474 standards
5. Reliable ACSR neutral messenger provides both grounding and mechanical strength
6. Custom messenger options (AAC or 6201 alloy) available for specific applications

Technical Specifications

4 Hackney Aluminum Conductor Quadruplex Overhead Service Drop Cable
4 Hackney Aluminum Conductor Quadruplex Overhead Service Drop Cable
Rated voltage kV 0.6/1
Test voltage Veff kV/Hz 4/50
Laying temperature °C min. -5
Operating temperature °C -30 ~ +90
Conductor temperature °C max. +90
Short-circuit temperature °C/s max. +250 /5
Bending radius (min.) mm 20 × Ø of cable

Quality Control

4 Hackney Aluminum Conductor Quadruplex Overhead Service Drop Cable
4 Hackney  Aluminum Conductor Quadruplex Service Drop Cable Material Test

Raw Material Test

Raw material testing for the 4 Hackney Quadruplex Service Drop Cable begins with aluminum wire inspection for purity, conductivity, and elongation per ASTM standards. Phase and messenger strands are checked for diameter uniformity and surface quality. XLPE/PE insulation compounds undergo melt flow index, density, carbon black content (UV protection), and thermal aging tests via OIT and DSC analysis. Samples face contamination screening and environmental stress cracking. The step-by-step process: incoming batch verification, sampling protocol, chemical composition analysis via spectrometry, mechanical property testing (before/after aging), electrical resistivity measurement, and material approval decision.

4 Hackney Aluminum Conductor Quadruplex Service Drop Cable  Process inspection

Process inspection

Process inspection during 4 Hackney Quadruplex Service Drop Cable production involves continuous monitoring. Phase conductor forming checks uniformity and surface quality. Insulation extrusion ensures void-free shields with real-time thickness gauges. Messenger preparation verifies integrity. Twisting assembly controls lay ratio, tension balance, and four-conductor symmetry. Critical steps: pre-extrusion compound dryness verification, parameter stabilization, capacitance-based eccentricity monitoring, gel fraction sampling, partial discharge intermediate checks, messenger coverage measurement, and defect removal protocols. This multi-stage assurance maintains the 4 Hackney Quadruplex Service Drop Cable's precise geometry, reliable messenger support, uniform insulation, and ASTM/ICEA compliance throughout manufacturing.

4 Hackney Aluminum Conductor Quadruplex Service Drop Cable  Finished Product

Finished Product

Completed 4 Hackney Quadruplex Service Drop Cable reels are subjected to strict tests. Mandatory routines: DC resistance, high-potential spark test, insulation thickness, messenger tensile strength, and total breaking load. Extended tests include switching impulse, long-duration voltage, heat cycling, and water tightness. The sequential process: sample conditioning, parameter application (voltage/heat), timed exposure monitoring, recovery inspection, property re-measurement, and documentation. Additional verifications ensure marking permanence and flexibility. Passing all confirms the 4 Hackney Quadruplex Service Drop Cable's electrical integrity, mechanical endurance, weather resistance, and suitability for critical overhead quadruplex applications.

Application

Perfect for medium voltage distribution in high-risk venues like metro systems, theaters, hotels, data centers, and commercial complexes requiring enhanced fire retardancy and higher CPR ratings. Commonly installed indoors or underground for superior protection and low smoke emission in densely populated environments.

Technical Advantages

● 30+ years of manufacturing experience
● ISO and UL certified production
● Customized cable and transformer solutions

Product Packaging

Wires and Cables packaging (1)
Wires and Cables packaging (1)
Wires and Cables packaging (2)
Wires and Cables packaging (2)
Wires and Cables packaging (3)
Wires and Cables packaging (3)
Wires and Cables packaging (4)
Wires and Cables packaging (4)
Wires and Cables packaging (5)
Wires and Cables packaging (5)
Wires and Cables packaging (6)
Wires and Cables packaging (6)
Wires and Cables packaging (7)
Wires and Cables packaging (7)
Wires and Cables packaging (8)
Wires and Cables packaging (8)

Related Products

FAQ From Customers

What are the advantages of power cables and overhead lines?
(1) Reliable operation, because it is installed in a hidden place such as underground, it is less damaged by external forces, has less chance of failure, and the power supply is safe, and it will not cause harm to people;
(2) The maintenance workload is small and frequent inspections are not required;
(3) No need to erect towers;
(4) Help improve power factor.
Which aspects should be considered when choosing the cross section of a power cable?
(1) The long-term allowable working current of the cable;
(2) Thermal stability once short circuited;
(3) The voltage drop on the line cannot exceed the allowable working range.
What are the measures for cable fire prevention?
(1) Use flame-retardant cables;
(2) Use fireproof cable tray;
(3) Use fireproof paint;
(4) Fire partition walls and fire baffles are installed at cable tunnels, mezzanine exits, etc.;
(5) Overhead cables should avoid oil pipelines and explosion-proof doors, otherwise local pipes or heat insulation and fire prevention measures should be taken.
What should be paid attention to during the transportation and handling of cables?
(1) During transportation, loading and unloading, cables and cable reels should not be damaged. It is strictly forbidden to push the cable reels directly from the vehicle. Generally, cables should not be transported and stored flat.
(2) Before transporting or rolling the cable reel, ensure that the cable reel is firm, the cable is wound tightly, the oil pipe between the oil-filled cable and the pressure oil tank should be fixed without damage, the pressure oil tank should be firm, and the pressure indication should meet the requirements.
What inspections should be carried out for the acceptance of cable lines?
(1) The cable specifications should meet the regulations, the arrangement should be neat, no damage, and the signs should be complete, correct and clear;
(2) The fixed bending radius of the cable, the related distance and the wiring of the metal sheath of the single-core power cable should meet the requirements;
(3) The cable terminal and the middle head should not leak oil, and the installation should be firm. The oil pressure of the oil-filled cable and the meter setting should meet the requirements;
(4) Good grounding;
(5) The color of the cable terminal is correct, and the metal parts such as the bracket are completely painted;
(6) There should be no debris in the cable trench, tunnel, and bridge, and the cover should be complete.