The FR-N30XA8E-AR Triplex 18/30kV Cable is a robust triplex medium-voltage cable compliant with NF C 33-226 for efficient power distribution. It comprises three stranded aluminium conductors (AL), semi-conductive screens, high-grade XLPE insulation for reliable dielectric/thermal performance (90°C continuous), copper wire screens for grounding, and a durable medium-density polyethylene (MDPE) outer sheath offering excellent mechanical protection, moisture resistance, UV stability, and chemical resistance. The triplex design (three cores twisted together) simplifies installation in overhead aerial bundled systems or underground ducts. Compliant with French NF C 33-226 and relevant IEC standards, it provides low losses, high current capacity, and long service life in demanding environments. The FR-N30XA8E-AR is perfect for MV overhead lines, underground distribution, rural electrification, and urban networks requiring weather-resistant, durable triplex cable.
Voltage Rating(Uo/U) 18/30 (36)kV
Maximum operating temp 90°C
Initial temp at S.C.C 80°C
Maximum temp during S.C 250°C
Minimum Bending Radius 20 x overall diameter
Construction
Technical Specifications
Quality Control
Application

Construction

FR-N30XA8E-AR 18/30kV Cable Constrution
FR-N30XA8E-AR 18/30kV Cable Constrution

Conductor

Class 2 stranded Aluminium

Conductor Screen

Extruded Inner Semi Conductor (Bonded Type)

Insulation

XLPE (Cross-Linked Polyethylene)

Insulation Screen

Extruded Inner Semi Conductor (Strippable Type)

Waterblocking

Semi Conductive Longitudinal Waterblocking Tape

Aluminium Tape

Applied Longitudinally

Sheath

MDPE (Medium Density Polyethylene)

Sheath Colour

Black

Manufacturer Standard

NF C 33-226, IEC 60502-2, EN 60228

Halogen free

IEC/EN 60754-1

Water resistant

AD7

UV resistant

ISO 4892

Technical Specifications

FR-N30XA8E-AR 18/30kV Cable Gen to NF C 33-226 - AL/XLPE/MDPE
FR-N30XA8E-AR 18/30kV Cable Data Sheet

No. of

Cores

Nominal Corss

Sectional Area

Nominal Screen Cross

Sectional Area

Nominal Conductor

Screen Thickness

Nominal Insulation

Screen Thickness

Nominal Sheath

Thickness

Nominal

Weight

  mm² mm² mm mm mm kg/km
1 50 18 0.6 0.7 1.9 819
1 70 20 0.6 0.7 1.9 939
1 95 21 0.6 0.7 2 1062
1 120 22 0.6 0.7 2.1 1193
1 150 23 0.6 0.7 2.1 1345
1 185 24 0.6 0.7 2.2 1477
1 240 25 0.6 0.7 2.2 1709
1 300 27 0.6 0.7 2.3 1972
1 400 29 0.6 0.7 2.4 2027
1 500 31 0.6 0.7 2.5 2741
1 630 34 0.7 0.7 2.6 3010
1 800 37 0.7 0.7 2.8 3718

Quality Control

FR-N30XA8E-AR 18/30kV Cable Gen to NF C 33-226 - AL/XLPE/MDPE
Raw Material Test

Raw Material Test

Raw Material Test for FR-N30XA8E-AR Triplex 18/30kV Cable prioritizes NF C 33-226 compliance. Steps include: Certification Verification: Aluminium conductors and XLPE/MDPE compounds meet NF C 33-226/IEC standards. Conductor Testing: Tensile, elongation, conductivity analysis. XLPE Evaluation: Tensile, elongation, dielectric strength, water tree resistance, hot set test. Semi-Conductive & Shielding Checks: Resistivity, adhesion, Cu wire coverage. MDPE Sheath Testing: Tensile, ESCR, UV stability, mechanical properties. Batch Rejection: Non-compliant quarantined. Approved materials ensure the FR-N30XA8E-AR Triplex 18/30kV Cable's MV performance.

Process inspection

Process inspection

Process Inspection for FR-N30XA8E-AR Triplex 18/30kV Cable enforces triplex quality. The procedure features: Stranding Control: Uniform aluminium stranding. Triple Extrusion: Conductor screen, XLPE, insulation screen monitored. Screening: Cu wire applied precisely. Triplex Assembly: Cores twisted with controlled lay. Sheath Extrusion: MDPE sheath with adhesion checks. Correction: Immediate fixes. This guarantees the FR-N30XA8E-AR Triplex 18/30kV Cable excels in MV distribution.

Finished Product

Finished Product

Finished Product Test validates the FR-N30XA8E-AR Triplex 18/30kV Cable for deployment. Steps include: Inspection: Visual/dimensional/marking verification. Electrical: Resistance, insulation, withstand, partial discharge. Mechanical: Bending, tensile, crush resistance. Performance: Thermal aging, water penetration checks. Validation: Ampacity/short-circuit confirmation. Release: Only passing FR-N30XA8E-AR Triplex 18/30kV Cable approved for reliable MV use.

Application

The FR-N30XA8E-AR Triplex 18/30kV Cable excels in 18/30 kV overhead aerial bundled lines, underground MV distribution, rural/urban electrification, substation feeders, renewable energy connections, and harsh environment installations requiring NF C 33-226 compliant, XLPE-insulated, MDPE-sheathed triplex cable with high mechanical and electrical performance.

Technical Advantages

● 30+ years of manufacturing experience
● ISO and UL certified production
● Customized cable and transformer solutions

Product Packaging

Wires and Cables packaging (1)
Wires and Cables packaging (1)
Wires and Cables packaging (2)
Wires and Cables packaging (2)
Wires and Cables packaging (3)
Wires and Cables packaging (3)
Wires and Cables packaging (4)
Wires and Cables packaging (4)
Wires and Cables packaging (5)
Wires and Cables packaging (5)
Wires and Cables packaging (6)
Wires and Cables packaging (6)
Wires and Cables packaging (7)
Wires and Cables packaging (7)
Wires and Cables packaging (8)
Wires and Cables packaging (8)

Related Products

FAQ From Customers

What are the advantages of power cables and overhead lines?
(1) Reliable operation, because it is installed in a hidden place such as underground, it is less damaged by external forces, has less chance of failure, and the power supply is safe, and it will not cause harm to people;
(2) The maintenance workload is small and frequent inspections are not required;
(3) No need to erect towers;
(4) Help improve power factor.
Which aspects should be considered when choosing the cross section of a power cable?
(1) The long-term allowable working current of the cable;
(2) Thermal stability once short circuited;
(3) The voltage drop on the line cannot exceed the allowable working range.
What are the measures for cable fire prevention?
(1) Use flame-retardant cables;
(2) Use fireproof cable tray;
(3) Use fireproof paint;
(4) Fire partition walls and fire baffles are installed at cable tunnels, mezzanine exits, etc.;
(5) Overhead cables should avoid oil pipelines and explosion-proof doors, otherwise local pipes or heat insulation and fire prevention measures should be taken.
What should be paid attention to during the transportation and handling of cables?
(1) During transportation, loading and unloading, cables and cable reels should not be damaged. It is strictly forbidden to push the cable reels directly from the vehicle. Generally, cables should not be transported and stored flat.
(2) Before transporting or rolling the cable reel, ensure that the cable reel is firm, the cable is wound tightly, the oil pipe between the oil-filled cable and the pressure oil tank should be fixed without damage, the pressure oil tank should be firm, and the pressure indication should meet the requirements.
What inspections should be carried out for the acceptance of cable lines?
(1) The cable specifications should meet the regulations, the arrangement should be neat, no damage, and the signs should be complete, correct and clear;
(2) The fixed bending radius of the cable, the related distance and the wiring of the metal sheath of the single-core power cable should meet the requirements;
(3) The cable terminal and the middle head should not leak oil, and the installation should be firm. The oil pressure of the oil-filled cable and the meter setting should meet the requirements;
(4) Good grounding;
(5) The color of the cable terminal is correct, and the metal parts such as the bracket are completely painted;
(6) There should be no debris in the cable trench, tunnel, and bridge, and the cover should be complete.