6 Collie Aluminum Conductor Duplex Overhead Service Drop Cable
Construction
Standard
• ASTM B-231 Aluminum Conductors, Concentric-Lay-Stranded.
• ASTM B-232 Aluminum Conductors, Concentric-Lay-Stranded, Coated Steel Reinforced (ACSR).
• ASTM B-399 Concentric-Lay-Stranded 6201-T81 Aluminum Alloy Conductors.
• ICEA S-76-474-Neutral-supported Power Cable Assemblies With Weather-Resistant Extruded Insulation Rated 600Volts
Phase Conductor
Insulation
Messenger Conductor
Application
Application Type
Technical Specifications
| Rated voltage | kV | 0.6/1 |
| Test voltage | Veff kV/Hz | 4/50 |
| Laying temperature | °C | min. -5 |
| Operating temperature | °C | -30 ~ +90 |
| Conductor temperature | °C | max. +90 |
| Short-circuit temperature | °C/s | max. +250 /5 |
| Bending radius (min.) | mm | 20 × Ø of cable |
Quality Control
Raw Material Test
Raw Material Test establishes the quality foundation of the 6 Collie Aluminum Conductor Duplex Overhead Service Drop Cable. Aluminum materials are examined for purity, conductivity, tensile strength, and elongation properties. Surface condition and dimensional tolerance are verified to ensure smooth processing during wire drawing and stranding. All incoming materials are recorded and fully traceable throughout manufacturing. Only aluminum rods that meet internal and international standards are approved for production, ensuring consistent quality and performance of the finished cable.
Process inspection
Process Inspection monitors each production stage of the 6 Collie Aluminum Conductor Duplex Overhead Service Drop Cable. Wire drawing parameters are tightly controlled to maintain uniform conductor diameter and surface quality. During stranding, conductor alignment, lay ratio, and tension balance are inspected. Continuous in-process checks prevent defects and ensure stable electrical and mechanical properties.
Finished Product
Finished Product Test validates the completed 6 Collie Aluminum Conductor Duplex Overhead Service Drop Cable. Electrical resistance tests confirm current-carrying capability, while mechanical tests verify tensile strength. Electrical resistance testing verifies conductivity performance, while tensile strength and elongation tests confirm mechanical integrity. Final inspections include dimensional checks, surface condition evaluation, marking accuracy, and packaging integrity to ensure compliance and installation readiness.
Application
Technical Advantages
Product Packaging
Related Products
FAQ From Customers
-
What are the advantages of power cables and overhead lines?(1) Reliable operation, because it is installed in a hidden place such as underground, it is less damaged by external forces, has less chance of failure, and the power supply is safe, and it will not cause harm to people; (2) The maintenance workload is small and frequent inspections are not required; (3) No need to erect towers; (4) Help improve power factor.
-
Which aspects should be considered when choosing the cross section of a power cable?(1) The long-term allowable working current of the cable; (2) Thermal stability once short circuited; (3) The voltage drop on the line cannot exceed the allowable working range.
-
What are the measures for cable fire prevention?(1) Use flame-retardant cables; (2) Use fireproof cable tray; (3) Use fireproof paint; (4) Fire partition walls and fire baffles are installed at cable tunnels, mezzanine exits, etc.; (5) Overhead cables should avoid oil pipelines and explosion-proof doors, otherwise local pipes or heat insulation and fire prevention measures should be taken.
-
What should be paid attention to during the transportation and handling of cables?(1) During transportation, loading and unloading, cables and cable reels should not be damaged. It is strictly forbidden to push the cable reels directly from the vehicle. Generally, cables should not be transported and stored flat. (2) Before transporting or rolling the cable reel, ensure that the cable reel is firm, the cable is wound tightly, the oil pipe between the oil-filled cable and the pressure oil tank should be fixed without damage, the pressure oil tank should be firm, and the pressure indication should meet the requirements.
-
What inspections should be carried out for the acceptance of cable lines?(1) The cable specifications should meet the regulations, the arrangement should be neat, no damage, and the signs should be complete, correct and clear; (2) The fixed bending radius of the cable, the related distance and the wiring of the metal sheath of the single-core power cable should meet the requirements; (3) The cable terminal and the middle head should not leak oil, and the installation should be firm. The oil pressure of the oil-filled cable and the meter setting should meet the requirements; (4) Good grounding; (5) The color of the cable terminal is correct, and the metal parts such as the bracket are completely painted; (6) There should be no debris in the cable trench, tunnel, and bridge, and the cover should be complete.