The ACSR Chickadee is a compact yet high-performance aluminium conductor steel reinforced cable, engineered for efficient energy transmission in overhead power systems. Constructed with hard-drawn 1350-H19 aluminium wires helically stranded around a galvanized steel core, this conductor is optimized to provide excellent electrical conductivity along with the mechanical strength needed for long-span and high-load applications. Compliant with ASTM B232 standards, the Chickadee conductor is suitable for primary and secondary bare cable use in transmission and distribution networks. The galvanized steel core, treated with Class A or B coating, ensures long-term corrosion resistance, even in aggressive outdoor environments. Ideal for compact power line installations or regions with light-to-moderate mechanical stress, Chickadee offers a reliable and cost-effective solution without compromising performance or safety.
Construction
Technical Specifications
Quality Control
Application

Construction

397.5 MCM CHICKADEE ACSR Conductor Cable Construction
397.5 MCM CHICKADEE ACSR Conductor Cable Construction

Standard

Product ASTM B232
The use of aluminum in electrical conductors is widespread, thanks to its exceptional electrical properties. However, in many transmission and distribution lines, aluminum conductors require supplementary mechanical strength, which is generally provided by galvanized steel wires within ACSR.

Construction

A concentrically stranded conductor, ACSR incorporates hard-drawn 1350-H19 aluminum wire layers over a galvanized steel wire core. The core may be single or stranded (size-dependent), and the steel wire is corrosion-resistant via Class A or B galvanization. Designed to comply with transmission and distribution lines’ electrical and mechanical strength demands, ACSR delivers tailored configurations by combining specific quantities of aluminum and galvanized steel wires.

Applications

Widely adopted as bare cable for overhead transmission lines, functioning simultaneously as primary and secondary bare cable in distribution lines.

Conditions for Ampacity Calculation

Conductor temperature = 75 °C;
Room temperature = 25 °C

Technical Specifications

397.5 MCM CHICKADEE ACSR Conductor Cable
397.5 MCM CHICKADEE ACSR Conductor Cable
Construction characteristics
Type of cable Chickadee
Type of conductor Circular, stranded
Conductor material aluminum / Steel Core
Conductor flexibility -
Conductor shape Circular non compacted
Dimensional characteristics
Conductor cross-section 397.5 kcmil
Aluminium cross-section 200.93 mm²
Conductor cross-section 212.09 mm²
Number of aluminium wires 18
Diameter of aluminium wires 3.77 mm
Number of steel wires 1
Diameter of steel wires 3.77 mm
Diameter of steel core 3.77 mm
Conductor diameter 18.85 mm
Average geometric radius 0.00733 m
Aluminium content 554 kg/km
Steel content 86.8 kg/km
Approximate weight 640.8 kg/km
Nominal outer diameter 18.85 mm
Number of cores 1
Number of round wires 19
Electrical characteristics
Max. DC resistance of the conductor at 20°C 0.1435 Ohm/km
Max. electric resistance AC 60Hz 75°C 0.173 Ohm/km
Inductive reactance 0.3708 Ohm/km
Capacitive reactance 0.2226 MOhm.km
Ampacity 580.0 A
Mechanical characteristics
Rated breaking load (Class A) 4603 kgf
Rated breaking load (Class B) 4526 kgf
Hardness type 1350-H19
Usage characteristics
Length 2090 m
Reel net weight 1340 kg
Packaging Reel 125/100

Quality Control

397.5 MCM CHICKADEE ACSR Conductor Cable
397.5 MCM CHICKADEE ACSR Conductor Cable  Raw Material Test

Raw Material Test

NPC has always chosen raw material suppliers who have a good reputation, possess stable supply capabilities and have passed international quality system certifications (such as ISO 9001). And establish a long-term cooperative relationship with it, forming a stable and reliable raw material supply chain.
We will ensure that all raw materials are subject to strict inspection procedures upon entry to the factory, and can only be stored in the warehouse after they have been confirmed to meet the standards.

397.5 MCM CHICKADEE ACSR Conductor Cable Process inspection

Process inspection

NPC has strict quality control procedures for each process in the cable production process.
Process documents: Develop detailed process flow and operation instructions to clarify the operating specifications and quality standards of each process.
Equipment calibration: Regularly calibrate key equipment such as wire drawing machines, stranding machines, extruders, and diameter gauges to ensure that the accuracy meets the requirements.
First piece confirmation: Before each batch of production, the first piece is trial-produced to confirm that the process parameters, product dimensions, electrical performance, etc. meet the standards before mass production can be carried out.

397.5 MCM CHICKADEE ACSR Conductor Cable Finished Product

Finished Product

Inspectors conduct ex-factory inspections on cables according to relevant standards and corresponding product inspection specifications to ensure that each ex-factory product complies with the process regulations.

Application

Widely adopted as bare cable for overhead transmission lines, functioning simultaneously as primary and secondary bare cable in distribution lines.

Technical Advantages

● 30+ years of manufacturing experience
● ISO and UL certified production
● Customized cable and transformer solutions

Product Packaging

Wires and Cables packaging (1)
Wires and Cables packaging (1)
Wires and Cables packaging (2)
Wires and Cables packaging (2)
Wires and Cables packaging (3)
Wires and Cables packaging (3)
Wires and Cables packaging (4)
Wires and Cables packaging (4)
Wires and Cables packaging (5)
Wires and Cables packaging (5)
Wires and Cables packaging (6)
Wires and Cables packaging (6)
Wires and Cables packaging (7)
Wires and Cables packaging (7)
Wires and Cables packaging (8)
Wires and Cables packaging (8)

Related Products

FAQ From Customers

What are the advantages of power cables and overhead lines?
(1) Reliable operation, because it is installed in a hidden place such as underground, it is less damaged by external forces, has less chance of failure, and the power supply is safe, and it will not cause harm to people;
(2) The maintenance workload is small and frequent inspections are not required;
(3) No need to erect towers;
(4) Help improve power factor.
Which aspects should be considered when choosing the cross section of a power cable?
(1) The long-term allowable working current of the cable;
(2) Thermal stability once short circuited;
(3) The voltage drop on the line cannot exceed the allowable working range.
What are the measures for cable fire prevention?
(1) Use flame-retardant cables;
(2) Use fireproof cable tray;
(3) Use fireproof paint;
(4) Fire partition walls and fire baffles are installed at cable tunnels, mezzanine exits, etc.;
(5) Overhead cables should avoid oil pipelines and explosion-proof doors, otherwise local pipes or heat insulation and fire prevention measures should be taken.
What should be paid attention to during the transportation and handling of cables?
(1) During transportation, loading and unloading, cables and cable reels should not be damaged. It is strictly forbidden to push the cable reels directly from the vehicle. Generally, cables should not be transported and stored flat.
(2) Before transporting or rolling the cable reel, ensure that the cable reel is firm, the cable is wound tightly, the oil pipe between the oil-filled cable and the pressure oil tank should be fixed without damage, the pressure oil tank should be firm, and the pressure indication should meet the requirements.
What inspections should be carried out for the acceptance of cable lines?
(1) The cable specifications should meet the regulations, the arrangement should be neat, no damage, and the signs should be complete, correct and clear;
(2) The fixed bending radius of the cable, the related distance and the wiring of the metal sheath of the single-core power cable should meet the requirements;
(3) The cable terminal and the middle head should not leak oil, and the installation should be firm. The oil pressure of the oil-filled cable and the meter setting should meet the requirements;
(4) Good grounding;
(5) The color of the cable terminal is correct, and the metal parts such as the bracket are completely painted;
(6) There should be no debris in the cable trench, tunnel, and bridge, and the cover should be complete.

Welcome your inquiry

Honesty, Integrity, Frugality, Activeness and Passion