x
2-Layer 15kV ACSR/AAC Tree Wire
2-Layer 15kV ACSR/AAC Tree Wire

2-Layer 15kV ACSR/AAC Tree Wire - Covered Overhead Distribution Cable

The 2-Layer 15kV ACSR/AAC Tree Wire is a covered overhead conductor designed for reliable medium-voltage distribution in areas with heavy tree contact. It features concentrically stranded ACSR or AAC conductors with a dual-layer covering of track-resistant high-density polyethylene (HDPE) or cross-linked polyethylene (XLPE). The inner layer provides insulation while the outer layer offers superior tracking and weathering resistance. This construction significantly reduces the risk of faults caused by tree limbs, minimizes wildfire ignition potential, and allows closer spacing to vegetation. Suitable for both spacer cable systems and conventional overhead lines, the 2-Layer 15kV ACSR/AAC Tree Wire meets ICEA S-121-733 and related ASTM standards. It undergoes rigorous quality testing from raw materials to finished product, ensuring excellent dielectric strength, mechanical robustness, and long-term performance in challenging environments.
Standards ICEA S-121-733, ASTM B230/B231/B232/B398
Voltage Rating 15 kV
Conductor ACSR or AAC (concentrically stranded)
Short-Circuit Tem 250°C
Operating Temp 90°C continuous
Emergency Temp 130°C
Construction
Technical Specifications
Quality Control
Application

Construction

2-Layer 15kV ACSR/AAC Tree Wire Constrution
2-Layer 15kV ACSR/AAC Tree Wire

Key Product Features

Dual-layer covering for superior tracking and abrasion resistance
ACSR or AAC conductor options for optimal strength-to-weight ratio
Reduced fault risk from tree contact and wildlife
Lower wildfire ignition potential compared to bare conductors
Compatible with spacer or conventional overhead systems

Covering

2-Layer HDPE or XLPE (typically 75 mils inner + 75 mils outer)

Insulation Level

100% or 133%

Covering Thickness:

Dual layer (150 mils total typical)

Configuration

Single covered conductor

Technical Specifications

2-Layer 15kV ACSR/AAC Tree Wire - Covered Overhead Distribution Cable
2-Layer 15kV ACSR Tree Wire Data Sheet
2-Layer 15kV AAC Tree Wire Data Sheet
Size (AWG or kcmil) Stranding Conductor Diameter (mils) Covering Thickness (mils) Cable O.D. Rated Strength (lbs) Weight per 1000 ft.(lbs)
Inner Layer Outer Layer
4 6/1 250 75 75 550 1767 136
2 6/1 316 75 75 616 2708 184
1/0 6/1 398 75 75 698 4161 255
2/0 6/1 447 75 75 747 5045 303
3/0 6/1 502 75 75 802 6289 362
4/0 6/1 563 75 75 863 7933 432
266.8 18/1 609 75 75 909 6536 441
266.8 26/7 642 75 75 942 10735 452
336.4 18/1 684 75 75 984 8246 536
336.4 26/7 720 75 75 1020 13395 555
336.4 30/7 741 75 75 1041 16435 621
397.5 18/1 743 75 75 1043 9443 611
397.5 24/7 772 75 75 1072 13870 609
397.5 26/7 783 75 75 1083 1545 645
477 24/7 846 75 75 1146 16340 719
477 26/7 858 75 75 1158 18525 762
477 30/7 883 75 75 1183 22610 854
556.5 18/1 879 75 75 1179 13015 813
556.5 24/7 914 75 75 1214 18810 828
556.5 26/7 927 75 75 1227 21470 878
636 18/1 940 75 75 1240 14915 912
636 24/7 977 75 75 1277 20900 936
636 26/7 990 75 75 1290 23940 993
795 26/7 1108 80 75 1428 29925 1234
795 45/7 1063 80 80 1383 20995 1031
Size (AWG or kcmil) Stranding Conductor Diameter (mils) Covering Thickness (mils) Cable O.D. (mils) Rated Strength (lbs) Weight per 1000 ft.(lbs)
  Inner Layer Outer Layer
1/0 7 336 75 75 636 1791 196
2/0 7 376 75 75 676 2259 230
3/0 7 423 75 75 723 2736 272
4/0 7 475 75 75 775 3447 325
266.8 19 537 75 75 837 4473 387
336.4 19 603 75 75 903 5535 466
397.5 19 659 75 75 959 6399 535
477 19 722 75 75 1022 7524 623
556.5 37 780 75 75 1080 8946 708
636 37 835 75 75 1135 10260 794

Quality Control

2-Layer 15kV ACSR/AAC Tree Wire - Covered Overhead Distribution Cable
Raw Material Test

Raw Material Test

Raw Material Test is the critical first step in manufacturing the 2-Layer 15kV ACSR/AAC Tree Wire. Incoming aluminum rods (for AAC) or aluminum and steel wires (for ACSR) undergo detailed chemical composition analysis to confirm purity and alloy requirements per ASTM B230/B231/B232. Mechanical testing verifies tensile strength, elongation, and hardness. HDPE or XLPE covering compounds are rigorously tested for thermal stability, tracking resistance, dielectric strength, and weatherability. Surface quality inspection and dimensional measurements detect any defects or inconsistencies. Only raw materials that fully pass every stringent criterion are approved for stranding and extrusion in the production of the 2-Layer 15kV ACSR/AAC Tree Wire. This thorough incoming inspection guarantees consistent conductivity, mechanical strength, and superior covering performance for reliable overhead tree wire applications.

Process inspection

Process inspection

Process Inspection during manufacturing of the 2-Layer 15kV ACSR/AAC Tree Wire maintains precise control at every stage. After conductor stranding (AAC or ACSR), continuous monitoring verifies dimensional tolerances and surface quality. The dual-layer covering extrusion process is carefully controlled for uniform thickness of both inner and outer layers, ensuring strong adhesion and absence of voids. Online diameter measurement systems and frequent visual checks prevent defects such as uneven covering or imperfections. Key process parameters including temperature, speed, and extrusion pressure are strictly logged. Mid-process sampling includes partial discharge and mechanical tests. Any deviation triggers immediate corrective action. These rigorous in-process controls safeguard the structural integrity and electrical properties of the 2-Layer 15kV ACSR/AAC Tree Wire, delivering a high-quality covered conductor ready for demanding overhead distribution service.

Finished Product

Finished Product

Finished Product testing ensures every reel of 2-Layer 15kV ACSR/AAC Tree Wire meets the highest quality standards. Comprehensive dimensional verification confirms overall diameter, covering thickness, and conductor stranding. DC resistance, high-voltage AC, and partial discharge tests validate electrical performance. Mechanical tests measure tensile strength and elongation. Full visual and tactile inspections check for surface defects or covering imperfections. Tracking and weathering resistance tests are performed on covering samples. All examinations follow ICEA S-121-733 and ASTM standards with detailed records for full traceability. Packaging and marking accuracy are also verified. Only the 2-Layer 15kV ACSR/AAC Tree Wire that successfully passes 100% of these final inspections receives approval for shipment. This rigorous final quality gate assures customers of outstanding dielectric strength, tracking resistance, and reliable performance in tree-prone overhead distribution lines.

Application

The 2-Layer 15kV ACSR/AAC Tree Wire is ideal for overhead distribution lines in forested or urban areas with heavy vegetation, spacer cable systems, reconductoring projects, and locations requiring reduced tree trimming and improved reliability against contact faults.

Technical Advantages

● 30+ years of manufacturing experience
● ISO and UL certified production
● Customized cable and transformer solutions

Product Packaging

Wires and Cables packaging (1)
Wires and Cables packaging (1)
Wires and Cables packaging (2)
Wires and Cables packaging (2)
Wires and Cables packaging (3)
Wires and Cables packaging (3)
Wires and Cables packaging (4)
Wires and Cables packaging (4)
Wires and Cables packaging (5)
Wires and Cables packaging (5)
Wires and Cables packaging (6)
Wires and Cables packaging (6)
Wires and Cables packaging (7)
Wires and Cables packaging (7)
Wires and Cables packaging (8)
Wires and Cables packaging (8)

Related Products

FAQ From Customers

What are the advantages of power cables and overhead lines?
(1) Reliable operation, because it is installed in a hidden place such as underground, it is less damaged by external forces, has less chance of failure, and the power supply is safe, and it will not cause harm to people;
(2) The maintenance workload is small and frequent inspections are not required;
(3) No need to erect towers;
(4) Help improve power factor.
Which aspects should be considered when choosing the cross section of a power cable?
(1) The long-term allowable working current of the cable;
(2) Thermal stability once short circuited;
(3) The voltage drop on the line cannot exceed the allowable working range.
What are the measures for cable fire prevention?
(1) Use flame-retardant cables;
(2) Use fireproof cable tray;
(3) Use fireproof paint;
(4) Fire partition walls and fire baffles are installed at cable tunnels, mezzanine exits, etc.;
(5) Overhead cables should avoid oil pipelines and explosion-proof doors, otherwise local pipes or heat insulation and fire prevention measures should be taken.
What should be paid attention to during the transportation and handling of cables?
(1) During transportation, loading and unloading, cables and cable reels should not be damaged. It is strictly forbidden to push the cable reels directly from the vehicle. Generally, cables should not be transported and stored flat.
(2) Before transporting or rolling the cable reel, ensure that the cable reel is firm, the cable is wound tightly, the oil pipe between the oil-filled cable and the pressure oil tank should be fixed without damage, the pressure oil tank should be firm, and the pressure indication should meet the requirements.
What inspections should be carried out for the acceptance of cable lines?
(1) The cable specifications should meet the regulations, the arrangement should be neat, no damage, and the signs should be complete, correct and clear;
(2) The fixed bending radius of the cable, the related distance and the wiring of the metal sheath of the single-core power cable should meet the requirements;
(3) The cable terminal and the middle head should not leak oil, and the installation should be firm. The oil pressure of the oil-filled cable and the meter setting should meet the requirements;
(4) Good grounding;
(5) The color of the cable terminal is correct, and the metal parts such as the bracket are completely painted;
(6) There should be no debris in the cable trench, tunnel, and bridge, and the cover should be complete.

Welcome your inquiry