The 2 Doberman Aluminum Conductor Duplex Overhead Service Drop Cable is designed to provide efficient and dependable power delivery in overhead secondary distribution systems. Constructed with stranded aluminum conductors, the duplex configuration combines electrical conductivity with mechanical support for service drop installations. The No. 2 Doberman size is suitable for standard service drop spans, offering reliable load capacity with controlled sag under varying environmental conditions. Aluminum conductors reduce overall cable weight, simplify handling, and enhance corrosion resistance for long-term outdoor operation. Produced under strict quality management systems, the 2 Doberman Aluminum Conductor Duplex Overhead Service Drop Cable meets utility and ASTM requirements, making it a trusted solution for modern overhead service connections where safety, durability, and consistent performance are essential.
Construction
Technical Specifications
Quality Control
Application

Construction

2 Doberman Aluminum Conductor Duplex Overhead Service Drop Cable Constrution
2 Doberman Aluminum Conductor Duplex Overhead Service Drop Cable

Standard

• ASTM B-230 Aluminum Wire, 1350-H19 for Electrical Purposes.
• ASTM B-231 Aluminum Conductors, Concentric-Lay-Stranded.
• ASTM B-232 Aluminum Conductors, Concentric-Lay-Stranded, Coated Steel Reinforced (ACSR).
• ASTM B-399 Concentric-Lay-Stranded 6201-T81 Aluminum Alloy Conductors.
• ICEA S-76-474-Neutral-supported Power Cable Assemblies With Weather-Resistant Extruded Insulation Rated 600Volts

Phase Conductor

Stranded compacted circular aluminum

Insulation

XLPE(UV-resistant)

Messenger Conductor

AAC/AAAC/ACSR

Application

Aluminum Conductor Duplex Overhead Service Drop Cable​​ is designed for supplying 120V to 600V aerial electrical service. It is ideal for applications such as temporary power at construction sites, street lighting, and outdoor lighting installations. The cable is rated for a maximum conductor temperature of 90°C.

Application Type

2 doberman aluminium overhead cables, 2 doberman overhead aluminum wire, 2 doberman two conductor cable, 2 doberman 2 conductor power cable, 2 doberman two conductor, 2 doberman aluminum drop, 2 doberman overhead service drop conductors, 2 doberman overhead service conductors.

Technical Specifications

2 Doberman Aluminum Conductor Duplex Overhead Service Drop Cable
2 Doberman Aluminum Conductor Duplex Overhead Service Drop Cable
Rated voltage kV 0.6/1
Test voltage Veff kV/Hz 4/50
Laying temperature °C min. -5
Operating temperature °C -30 ~ +90
Conductor temperature °C max. +90
Short-circuit temperature °C/s max. +250 /5
Bending radius (min.) mm 20 × Ø of cable

Quality Control

2 Doberman Aluminum Conductor Duplex Overhead Service Drop Cable
2 Doberman Aluminum Conductor Duplex Overhead Service Drop Cable Material Test

Raw Material Test

Raw Material Test establishes the quality foundation of the 2 Doberman Aluminum Conductor Duplex Overhead Service Drop Cable. Aluminum materials are examined for purity, conductivity, tensile strength, and elongation properties. Surface finish and dimensional tolerances are verified to ensure smooth processing during wire drawing and stranding. All incoming materials are recorded and traceable throughout production. Only aluminum rods that meet internal and international standards are approved for manufacturing, ensuring consistent quality in the finished cable.

2 Doberman Aluminum Conductor Duplex Overhead Service Drop Cable Process inspection

Process inspection

Process Inspection monitors each production step of the 2 Doberman Aluminum Conductor Duplex Overhead Service Drop Cable. Wire drawing parameters are tightly controlled to maintain uniform conductor diameter and surface quality. During stranding, conductor alignment, lay ratio, and tension balance are inspected. Continuous in-process checks prevent defects and ensure stable electrical and mechanical properties.

2 Doberman Aluminum Conductor Duplex Overhead Service Drop Cable Finished Product

Finished Product

Finished Product Test validates the completed 2 Doberman Aluminum Conductor Duplex Overhead Service Drop Cable. Electrical resistance tests confirm current-carrying capability, while mechanical tests verify tensile strength. Final inspections include dimensional checks, surface condition evaluation, marking accuracy, and packaging integrity to ensure compliance and installation readiness.

Application

Ideal for overhead service drop installations delivering secondary power to residential, commercial, and light industrial service entrances.

Technical Advantages

● 30+ years of manufacturing experience
● ISO and UL certified production
● Customized cable and transformer solutions

Product Packaging

Wires and Cables packaging (1)
Wires and Cables packaging (1)
Wires and Cables packaging (2)
Wires and Cables packaging (2)
Wires and Cables packaging (3)
Wires and Cables packaging (3)
Wires and Cables packaging (4)
Wires and Cables packaging (4)
Wires and Cables packaging (5)
Wires and Cables packaging (5)
Wires and Cables packaging (6)
Wires and Cables packaging (6)
Wires and Cables packaging (7)
Wires and Cables packaging (7)
Wires and Cables packaging (8)
Wires and Cables packaging (8)

Related Products

FAQ From Customers

What are the advantages of power cables and overhead lines?
(1) Reliable operation, because it is installed in a hidden place such as underground, it is less damaged by external forces, has less chance of failure, and the power supply is safe, and it will not cause harm to people;
(2) The maintenance workload is small and frequent inspections are not required;
(3) No need to erect towers;
(4) Help improve power factor.
Which aspects should be considered when choosing the cross section of a power cable?
(1) The long-term allowable working current of the cable;
(2) Thermal stability once short circuited;
(3) The voltage drop on the line cannot exceed the allowable working range.
What are the measures for cable fire prevention?
(1) Use flame-retardant cables;
(2) Use fireproof cable tray;
(3) Use fireproof paint;
(4) Fire partition walls and fire baffles are installed at cable tunnels, mezzanine exits, etc.;
(5) Overhead cables should avoid oil pipelines and explosion-proof doors, otherwise local pipes or heat insulation and fire prevention measures should be taken.
What should be paid attention to during the transportation and handling of cables?
(1) During transportation, loading and unloading, cables and cable reels should not be damaged. It is strictly forbidden to push the cable reels directly from the vehicle. Generally, cables should not be transported and stored flat.
(2) Before transporting or rolling the cable reel, ensure that the cable reel is firm, the cable is wound tightly, the oil pipe between the oil-filled cable and the pressure oil tank should be fixed without damage, the pressure oil tank should be firm, and the pressure indication should meet the requirements.
What inspections should be carried out for the acceptance of cable lines?
(1) The cable specifications should meet the regulations, the arrangement should be neat, no damage, and the signs should be complete, correct and clear;
(2) The fixed bending radius of the cable, the related distance and the wiring of the metal sheath of the single-core power cable should meet the requirements;
(3) The cable terminal and the middle head should not leak oil, and the installation should be firm. The oil pressure of the oil-filled cable and the meter setting should meet the requirements;
(4) Good grounding;
(5) The color of the cable terminal is correct, and the metal parts such as the bracket are completely painted;
(6) There should be no debris in the cable trench, tunnel, and bridge, and the cover should be complete.