6 Hippa Aluminum Conductor Triplex Overhead Service Drop Cable Wire
6 Hippa Aluminum Conductor Triplex Overhead Service Drop Cable Wire

6 Hippa Aluminum Conductor Triplex Overhead Service Drop Cable Wire

6 Hippa Aluminum Conductor Triplex Overhead Service Drop Cable Wire is engineered for safe and efficient overhead service drop connections. It features two insulated aluminum conductors stranded around a reinforced neutral messenger, providing balanced electrical performance and mechanical stability. This cable offers excellent corrosion resistance, low sag characteristics, and simplified installation. The insulation system of the 6 Hippa Aluminum Conductor Triplex Overhead Service Drop Cable Wire is designed to withstand prolonged exposure to sunlight, moisture, and temperature variations, ensuring reliable outdoor operation. A complete quality assurance program is implemented during manufacturing, covering raw material testing, process inspection, and finished product testing. Each production stage follows standardized procedures to ensure conformity with international standards and utility requirements. The 6 Hippa Aluminum Conductor Triplex Overhead Service Drop Cable Wire is a dependable choice for modern overhead power distribution systems.
Construction
Technical Specifications
Quality Control
Application

Construction

6 Hippa Aluminum Conductor Triplex Overhead Service Drop Cable Constrution
6 Hippa Aluminum Conductor Triplex Overhead Service Drop Cable

Standard

• ASTM B-230 Aluminum Wire, 1350-H19 for Electrical Purposes.
• ASTM B-231 Aluminum Conductors, Concentric-Lay-Stranded.
• ASTM B-232 Aluminum Conductors, Concentric-Lay-Stranded, Coated Steel Reinforced (ACSR).
• ASTM B-399 Concentric-Lay-Stranded 6201-T81 Aluminum Alloy Conductors.
ASTM B-498 Zinc-Coated Steel Core Wire for Aluminum Conductors, Steel Reinforced (ACSR).
• Triplex Service Drop cable meets or exceeds all applicable requirements of ANSI/ICEA body S-76-474.

Phase Conductor

Strand or Compressed 1350-H19 Series Aluminum Conductor.

Neutral (Messenger) Conductor

Bare AAAC messenger.

Insulation

Black Cross Linked Polyethylene (XLP) Insulation.

Key Features

1. Bare AAAC messenger for corrosion resistance and strength
2. Designed for single-phase 120/240V overhead service drops
3. XLP insulation for weather, UV, and abrasion resistance
4. Fully compliant with ASTM and ICEA standards
5. Suitable for long-span installations

Application

6 Hippa Triplex aluminum wire has three conductors, with one of them being for the neutral path, and two electrodes. Used to supply power, usually from a pole-mounted transformer, to the user's service head, where connection to the service entrance cable is made. To be used at voltages of 600 volts phase-to-phase or less and at conductor temperatures not to exceed 75°C for polyethylene insulated conductors or 90°C for cross-linked polyethylene (XLPE) insulated conductors.

Technical Specifications

6 Hippa Aluminum Conductor Triplex Overhead Service Drop Cable Wire
6 Hippa Aluminum Conductor Triplex Overhead Service Drop Cable
Rated voltage V 600
Test voltage Veff kV/Hz 4/50
Laying temperature °C min. -5
Operating temperature °C -30 ~ +90
Conductor temperature °C max. +90
Short-circuit temperature °C/s max. +250 /5
Bending radius (min.) mm 20 × Ø of cable

Quality Control

6 Hippa Aluminum Conductor Triplex Overhead Service Drop Cable Wire
6 Hippa Mursia Aluminum Conductor Triplex Overhead Service Drop Cable Material Test

Raw Material Test

For the 6 Hippa Aluminum Conductor Triplex Overhead Service Drop Cable Wire, raw material testing ensures that all input materials meet strict quality criteria. Aluminum rods undergo chemical composition analysis to verify purity and conductivity performance. Electrical conductivity testing confirms compliance with transmission requirements. Mechanical properties such as tensile strength and elongation are tested to ensure the aluminum can withstand manufacturing and installation stress. Surface inspections detect defects, oxidation, or contamination. Nonconforming materials are rejected before production.

6 Hippa Aluminum Conductor Triplex Overhead Service Drop Cable Process inspection

Process inspection

Process inspection is essential to maintaining quality during production of the 6 Hippa Aluminum Conductor Triplex Overhead Service Drop Cable Wire. Conductor stranding inspections verify strand count, lay length, and diameter accuracy to ensure uniform electrical performance. During insulation extrusion, continuous monitoring checks insulation thickness and concentricity. Spark testing identifies insulation defects instantly, preventing defective sections from advancing. Temperature and extrusion parameters are strictly controlled.

6 Hippa Aluminum Conductor Triplex Overhead Service Drop Cable Finished Product

Finished Product

Finished product testing validates the final quality of the 6 Hippa Aluminum Conductor Triplex Overhead Service Drop Cable Wire. Electrical resistance and high-voltage tests confirm conductor efficiency and insulation reliability. Mechanical tests evaluate tensile strength and insulation adhesion. Dimensional measurements ensure compliance with design tolerances. Environmental tests such as heat aging, cold bending, and UV resistance simulate service conditions.

Application

The 6 Hippa Aluminum Conductor Triplex Overhead Service Drop Cable Wire is suitable for overhead electrical connections between utility distribution networks and service entrances of residential, commercial, and light industrial buildings.

Technical Advantages

● 30+ years of manufacturing experience
● ISO and UL certified production
● Customized cable and transformer solutions

Product Packaging

Wires and Cables packaging (1)
Wires and Cables packaging (1)
Wires and Cables packaging (2)
Wires and Cables packaging (2)
Wires and Cables packaging (3)
Wires and Cables packaging (3)
Wires and Cables packaging (4)
Wires and Cables packaging (4)
Wires and Cables packaging (5)
Wires and Cables packaging (5)
Wires and Cables packaging (6)
Wires and Cables packaging (6)
Wires and Cables packaging (7)
Wires and Cables packaging (7)
Wires and Cables packaging (8)
Wires and Cables packaging (8)

Related Products

FAQ From Customers

What are the advantages of power cables and overhead lines?
(1) Reliable operation, because it is installed in a hidden place such as underground, it is less damaged by external forces, has less chance of failure, and the power supply is safe, and it will not cause harm to people;
(2) The maintenance workload is small and frequent inspections are not required;
(3) No need to erect towers;
(4) Help improve power factor.
Which aspects should be considered when choosing the cross section of a power cable?
(1) The long-term allowable working current of the cable;
(2) Thermal stability once short circuited;
(3) The voltage drop on the line cannot exceed the allowable working range.
What are the measures for cable fire prevention?
(1) Use flame-retardant cables;
(2) Use fireproof cable tray;
(3) Use fireproof paint;
(4) Fire partition walls and fire baffles are installed at cable tunnels, mezzanine exits, etc.;
(5) Overhead cables should avoid oil pipelines and explosion-proof doors, otherwise local pipes or heat insulation and fire prevention measures should be taken.
What should be paid attention to during the transportation and handling of cables?
(1) During transportation, loading and unloading, cables and cable reels should not be damaged. It is strictly forbidden to push the cable reels directly from the vehicle. Generally, cables should not be transported and stored flat.
(2) Before transporting or rolling the cable reel, ensure that the cable reel is firm, the cable is wound tightly, the oil pipe between the oil-filled cable and the pressure oil tank should be fixed without damage, the pressure oil tank should be firm, and the pressure indication should meet the requirements.
What inspections should be carried out for the acceptance of cable lines?
(1) The cable specifications should meet the regulations, the arrangement should be neat, no damage, and the signs should be complete, correct and clear;
(2) The fixed bending radius of the cable, the related distance and the wiring of the metal sheath of the single-core power cable should meet the requirements;
(3) The cable terminal and the middle head should not leak oil, and the installation should be firm. The oil pressure of the oil-filled cable and the meter setting should meet the requirements;
(4) Good grounding;
(5) The color of the cable terminal is correct, and the metal parts such as the bracket are completely painted;
(6) There should be no debris in the cable trench, tunnel, and bridge, and the cover should be complete.