25kV 3-Layer AAAC/ACSR/AAC Tree Wire - Triple Layer Covered MV Conductor
- Standards ICEA S-121-733, ASTM B230/B231/B232/B398/B399
- Voltage Rating 25 kV
- Conductor AAAC, ACSR, or AAC (concentrically stranded)
- Short-Circuit Tem 250°C
- Operating Temp 90°C continuous
- Emergency Temp 130°C
Construction
Key Product Features
AAAC, ACSR, or AAC conductor options for optimal strength
Significantly reduced fault risk from vegetation contact
Lower maintenance and wildfire mitigation benefits
Compatible with spacer cable configurations
Covering
Insulation Level
Covering Thickness
Configuration
Technical Specifications
| Size (AWG or kcmil) | Stranding | Conductor Diameter (mils) | Covering Thickness (mils) | Cable O.D. (mils) | Rated Strength (lbs) | Weight per 1000 ft.(lbs) | ||
| Conductor Shield | Inner Layer | Outer Layer | ||||||
| 1/0 | 6/1 | 398 | 15 | 125 | 125 | 928 | 4161 | 385 |
| 2/0 | 6/1 | 447 | 15 | 125 | 125 | 977 | 5045 | 443 |
| 3/0 | 6/1 | 502 | 15 | 125 | 125 | 1032 | 6289 | 513 |
| 4/0 | 6/1 | 563 | 15 | 125 | 125 | 1093 | 7933 | 600 |
| 266.8 | 18/1 | 609 | 15 | 125 | 125 | 1139 | 6536 | 608 |
| 266.8 | 26/7 | 642 | 15 | 125 | 125 | 1172 | 10735 | 692 |
| 336.4 | 18/1 | 684 | 15 | 125 | 125 | 1214 | 8246 | 714 |
| 336.4 | 26/7 | 720 | 15 | 125 | 125 | 1250 | 13395 | 818 |
| 336.4 | 30/7 | 741 | 15 | 125 | 125 | 1271 | 16435 | 1086 |
| 397.5 | 18/1 | 743 | 15 | 125 | 125 | 1273 | 9443 | 804 |
| 397.5 | 24/7 | 772 | 15 | 125 | 125 | 1302 | 13870 | 863 |
| 397.5 | 26/7 | 783 | 15 | 125 | 125 | 1313 | 15485 | 926 |
| 477 | 24/7 | 846 | 20 | 125 | 125 | 1386 | 16340 | 999 |
| 477 | 26/7 | 858 | 20 | 125 | 125 | 1398 | 18525 | 1076 |
| 477 | 30/7 | 883 | 20 | 125 | 125 | 1423 | 22610 | 1458 |
| 556.5 | 18/1 | 879 | 20 | 125 | 125 | 1419 | 13015 | 1045 |
| 556.5 | 24/7 | 914 | 20 | 125 | 125 | 1454 | 18810 | 1124 |
| 556.5 | 26/7 | 927 | 20 | 125 | 125 | 1467 | 21470 | 1213 |
| Size (kcmil) | Equivalent AAC (AWG or kcmil) | Stranding | Conductor Diameter (mils) | Covering Thickness (mils) | Cable O.D. (mils) | Rated Strength (lbs) | Weight per 1000 ft.(lbs) | ||
| Conductor Shield | Inner Layer | Outer Layer | |||||||
| 48.69 | 4 | 7 | 250 | 15 | 125 | 125 | 780 | 1584 | 225 |
| 77.47 | 2 | 7 | 316 | 15 | 125 | 125 | 846 | 2520 | 275 |
| 123.3 | 1/0 | 7 | 398 | 15 | 125 | 125 | 928 | 4014 | 348 |
| 155.4 | 2/0 | 7 | 447 | 15 | 125 | 125 | 977 | 4851 | 396 |
| 195.7 | 3/0 | 7 | 502 | 15 | 125 | 125 | 1032 | 6111 | 454 |
| 246.9 | 4/0 | 7 | 563 | 15 | 125 | 125 | 1093 | 7704 | 525 |
| 312.8 | 266.8 | 19 | 642 | 15 | 125 | 125 | 1172 | 9900 | 611 |
| 394.5 | 336.4 | 19 | 720 | 15 | 125 | 125 | 1251 | 11970 | 716 |
| 465.4 | 397.5 | 19 | 783 | 15 | 125 | 125 | 1313 | 14040 | 805 |
| 559.5 | 477 | 19 | 858 | 20 | 125 | 125 | 1398 | 16920 | 932 |
| 652.4 | 556.5 | 19 | 927 | 20 | 125 | 125 | 1467 | 19710 | 1044 |
| 740.8 | 636 | 37 | 990 | 20 | 125 | 125 | 1530 | 21960 | 1148 |
| 927.2 | 795 | 37 | 1108 | 20 | 125 | 125 | 1648 | 27450 | 1389 |
| Size (AWG or kcmil) | Stranding | Conductor Diameter (mils) | Covering Thickness (mils) | Cable O.D. (mils) | Rated Strength (lbs) | Weight per 1000 ft.(lbs) | ||
| Conductor Shield | Inner Layer | Outer Layer | ||||||
| 1/0 | 7 | 336 | 15 | 125 | 125 | 866 | 1791 | 309 |
| 2/0 | 7 | 376 | 15 | 125 | 125 | 906 | 2259 | 350 |
| 3/0 | 7 | 423 | 15 | 125 | 125 | 953 | 2736 | 400 |
| 4/0 | 7 | 475 | 15 | 125 | 125 | 1005 | 3447 | 460 |
| 266.8 | 19 | 537 | 15 | 125 | 125 | 1067 | 4473 | 531 |
| 336.4 | 19 | 603 | 15 | 125 | 125 | 1133 | 5535 | 621 |
| 397.5 | 19 | 659 | 15 | 125 | 125 | 1189 | 6399 | 698 |
| 477 | 19 | 722 | 20 | 125 | 125 | 1262 | 7524 | 806 |
| 556.5 | 37 | 780 | 20 | 125 | 125 | 1320 | 8946 | 899 |
| 636 | 37 | 835 | 20 | 125 | 125 | 1375 | 10260 | 995 |
| 795 | 37 | 932 | 20 | 125 | 125 | 1472 | 12510 | 1181 |
Quality Control
Raw Material Test
Raw Material Test for the 3-Layer 25kV AAAC/ACSR/AAC Tree Wire involves rigorous evaluation of conductor materials and covering compounds. Chemical analysis confirms aluminum purity and alloy composition (for AAAC/AAC) or steel/aluminum for ACSR. Mechanical properties such as tensile strength, elongation, and hardness are tested to meet ASTM requirements. HDPE or XLPE compounds undergo thermal stability, tracking resistance, dielectric strength, and weatherability testing. Detailed surface and dimensional inspections identify any potential defects before processing. Only fully compliant raw materials are released for stranding and triple-layer extrusion in the production of the 3-Layer 25kV AAAC/ACSR/AAC Tree Wire. This comprehensive raw material validation establishes the foundation for superior electrical performance, mechanical strength, and long-term reliability in multi-layer tree wire applications.
Process inspection
Process Inspection throughout manufacturing of the 3-Layer 25kV AAAC/ACSR/AAC Tree Wire focuses on precision and consistency. Conductor stranding is monitored to achieve exact dimensions with continuous quality checks. Triple tandem or sequential extrusion of the three covering layers ensures clean interfaces and uniform thickness. Concentric application of layers uses automated tension control for even coverage. Jacket parameters are strictly controlled for proper thickness and adhesion. Frequent in-line diameter measurements and visual inspections catch anomalies immediately. Environmental and process variables are logged to prevent contamination. Intermediate samples undergo partial discharge and mechanical spot testing. Any non-conformance prompts swift corrective measures. These detailed process controls protect the integrity and performance characteristics of the 3-Layer 25kV AAAC/ACSR/AAC Tree Wire, resulting in a uniform, high-quality covered tree wire.
Finished Product
Every completed reel of 3-Layer 25kV AAAC/ACSR/AAC Tree Wire passes comprehensive Finished Product testing. Dimensional inspections verify overall diameter, covering thickness, and conductor stranding. DC resistance, high-voltage AC, and partial discharge tests confirm compliance with ICEA and ASTM standards. Mechanical tests measure tensile strength and elongation properties. Tracking and weathering resistance tests are performed on covering samples. Full visual examination ensures a smooth, defect-free surface with uniform layers. All tests adhere strictly to applicable standards, with complete documentation and batch traceability maintained. Packaging and labeling are inspected for accuracy. Only the 3-Layer 25kV AAAC/ACSR/AAC Tree Wire that meets every quality criterion receives final approval. This final assurance stage guarantees customers a premium triple-layer tree wire with proven dielectric strength, tracking resistance, and durability for reliable overhead distribution in vegetated areas.
Application
Technical Advantages
Product Packaging
Related Products
FAQ From Customers
-
What are the advantages of power cables and overhead lines?(1) Reliable operation, because it is installed in a hidden place such as underground, it is less damaged by external forces, has less chance of failure, and the power supply is safe, and it will not cause harm to people; (2) The maintenance workload is small and frequent inspections are not required; (3) No need to erect towers; (4) Help improve power factor.
-
Which aspects should be considered when choosing the cross section of a power cable?(1) The long-term allowable working current of the cable; (2) Thermal stability once short circuited; (3) The voltage drop on the line cannot exceed the allowable working range.
-
What are the measures for cable fire prevention?(1) Use flame-retardant cables; (2) Use fireproof cable tray; (3) Use fireproof paint; (4) Fire partition walls and fire baffles are installed at cable tunnels, mezzanine exits, etc.; (5) Overhead cables should avoid oil pipelines and explosion-proof doors, otherwise local pipes or heat insulation and fire prevention measures should be taken.
-
What should be paid attention to during the transportation and handling of cables?(1) During transportation, loading and unloading, cables and cable reels should not be damaged. It is strictly forbidden to push the cable reels directly from the vehicle. Generally, cables should not be transported and stored flat. (2) Before transporting or rolling the cable reel, ensure that the cable reel is firm, the cable is wound tightly, the oil pipe between the oil-filled cable and the pressure oil tank should be fixed without damage, the pressure oil tank should be firm, and the pressure indication should meet the requirements.
-
What inspections should be carried out for the acceptance of cable lines?(1) The cable specifications should meet the regulations, the arrangement should be neat, no damage, and the signs should be complete, correct and clear; (2) The fixed bending radius of the cable, the related distance and the wiring of the metal sheath of the single-core power cable should meet the requirements; (3) The cable terminal and the middle head should not leak oil, and the installation should be firm. The oil pressure of the oil-filled cable and the meter setting should meet the requirements; (4) Good grounding; (5) The color of the cable terminal is correct, and the metal parts such as the bracket are completely painted; (6) There should be no debris in the cable trench, tunnel, and bridge, and the cover should be complete.