2/0 Triton Aluminum Conductor Triplex Overhead Service Drop Cable
2/0 Triton Aluminum Conductor Triplex Overhead Service Drop Cable

2/0 Triton Aluminum Conductor Triplex Overhead Service Drop Cable

The 2/0 Triton Aluminum Triplex Overhead Service Drop Cable is a reliable, high-performance cable solution designed for aerial power delivery from pole-mounted transformers to end-user service entrances. This triplex cable features two insulated phase conductors and one bare neutral messenger, ensuring robust support and electrical continuity. The insulated phase conductors use cross-linked polyethylene (XLPE) for superior thermal resistance, weather endurance, and long-term reliability in overhead service applications. With a voltage rating of 600V and temperature endurance up to 75°C, the Triton triplex cable is a preferred option for residential and light commercial power distribution.
Construction
Technical Specifications
Quality Control
Application

Construction

2/0 Triton Aluminum Conductor Triplex Overhead Service Drop Cable Constrution
2/0 Triton Aluminum Conductor Triplex Overhead Service Drop Cable

Standard

• ASTM B-230 Aluminum Wire, 1350-H19 for Electrical Purposes.
• ASTM B-231 Aluminum Conductors, Concentric-Lay-Stranded.
• ASTM B-232 Aluminum Conductors, Concentric-Lay-Stranded, Coated Steel Reinforced (ACSR).
• ASTM B-399 Concentric-Lay-Stranded 6201-T81 Aluminum Alloy Conductors.
• ICEA S-76-474-Neutral-supported Power Cable Assemblies With Weather-Resistant Extruded Insulation Rated 600 Volts.

Phase Conductor

Strand or Compressed 1350-H19 Series Aluminum Conductor.

Neutral (Messenger) Conductor

Bare AAAC messenger.

Insulation

Black Cross Linked Polyethylene (XLP) Insulation.

Key Features

1. Voltage Rating: 600V
2. Temperature Rating: 75°C for PE, 90°C for XLPE
3. Phase Conductors: 1350-H19 Aluminum
4. Messenger: Bare ACSR (Optional: AAC or 6201 Alloy)
5. UV- and moisture-resistant insulation for long-lasting overhead use

Application

2/0 Triton Triplex aluminum wire has three conductors, with one of them being for the neutral path, and two electrodes. The aluminum triplex cable is an electrical cable meant for power distribution from the utility lines to the consumer’s premises through the weather head. It has an operational voltage rating of 600 V and a maximum temperature rating of 75°C. A bare messenger wire of this electrical cable is bonded closely to the two insulated aluminum conductors, which are individually insulated with black cross-linked polyethylene for protection.

Also Known As

2/0 triton triplex aluminum wire, 2/0 triton triplex overhead wire, 2/0 triton aluminum triplex, 2/0 triton triplex conductor, 2/0 triton overhead aluminum wire, 2/0 triton aluminium overhead cables, 2/0 triton overhead service drop conductors.

Technical Specifications

2/0 Triton Aluminum Conductor Triplex Overhead Service Drop Cable
2/0 Triton Aluminum Conductor Triplex Overhead Service Drop Cable
Rated voltage V 600
Test voltage Veff kV/Hz 4/50
Laying temperature °C min. -5
Operating temperature °C -30 ~ +90
Conductor temperature °C max. +90
Short-circuit temperature °C/s max. +250 /5
Bending radius (min.) mm 20 × Ø of cable

Quality Control

2/0 Triton Aluminum Conductor Triplex Overhead Service Drop Cable
2/0 Triton Aluminum Conductor Triplex Overhead Service Drop Cable Material Test

Raw Material Test

NPC has always chosen raw material suppliers who have a good reputation, possess stable supply capabilities and have passed international quality system certifications (such as ISO 9001). And establish a long-term cooperative relationship with it, forming a stable and reliable raw material supply chain.
We will ensure that all raw materials are subject to strict inspection procedures upon entry to the factory, and can only be stored in the warehouse after they have been confirmed to meet the standards.

2/0 Triton Aluminum Conductor Triplex Overhead Service Drop Cable Process inspection

Process inspection

NPC has strict quality control procedures for each process in the cable production process.
Process documents: Develop detailed process flow and operation instructions to clarify the operating specifications and quality standards of each process.
Equipment calibration: Regularly calibrate key equipment such as wire drawing machines, stranding machines, extruders, and diameter gauges to ensure that the accuracy meets the requirements.
First piece confirmation: Before each batch of production, the first piece is trial-produced to confirm that the process parameters, product dimensions, electrical performance, etc. meet the standards before mass production can be carried out.

2/0 Triton Aluminum Conductor Triplex Overhead Service Drop Cable Finished Product

Finished Product

Inspectors conduct ex-factory inspections on cables according to relevant standards and corresponding product inspection specifications to ensure that each ex-factory product complies with the process regulations.

Application

2/0 Triton Triplex aluminum wire has an operational voltage rating of 600 V and a maximum temperature rating of 75°C. A bare messenger wire of this electrical cable is bonded closely to the two insulated aluminum conductors, which are individually insulated with black cross-linked polyethylene for protection.

Technical Advantages

● 30+ years of manufacturing experience
● ISO and UL certified production
● Customized cable and transformer solutions

Product Packaging

Wires and Cables packaging (1)
Wires and Cables packaging (1)
Wires and Cables packaging (2)
Wires and Cables packaging (2)
Wires and Cables packaging (3)
Wires and Cables packaging (3)
Wires and Cables packaging (4)
Wires and Cables packaging (4)
Wires and Cables packaging (5)
Wires and Cables packaging (5)
Wires and Cables packaging (6)
Wires and Cables packaging (6)
Wires and Cables packaging (7)
Wires and Cables packaging (7)
Wires and Cables packaging (8)
Wires and Cables packaging (8)

Related Products

FAQ From Customers

What are the advantages of power cables and overhead lines?
(1) Reliable operation, because it is installed in a hidden place such as underground, it is less damaged by external forces, has less chance of failure, and the power supply is safe, and it will not cause harm to people;
(2) The maintenance workload is small and frequent inspections are not required;
(3) No need to erect towers;
(4) Help improve power factor.
Which aspects should be considered when choosing the cross section of a power cable?
(1) The long-term allowable working current of the cable;
(2) Thermal stability once short circuited;
(3) The voltage drop on the line cannot exceed the allowable working range.
What are the measures for cable fire prevention?
(1) Use flame-retardant cables;
(2) Use fireproof cable tray;
(3) Use fireproof paint;
(4) Fire partition walls and fire baffles are installed at cable tunnels, mezzanine exits, etc.;
(5) Overhead cables should avoid oil pipelines and explosion-proof doors, otherwise local pipes or heat insulation and fire prevention measures should be taken.
What should be paid attention to during the transportation and handling of cables?
(1) During transportation, loading and unloading, cables and cable reels should not be damaged. It is strictly forbidden to push the cable reels directly from the vehicle. Generally, cables should not be transported and stored flat.
(2) Before transporting or rolling the cable reel, ensure that the cable reel is firm, the cable is wound tightly, the oil pipe between the oil-filled cable and the pressure oil tank should be fixed without damage, the pressure oil tank should be firm, and the pressure indication should meet the requirements.
What inspections should be carried out for the acceptance of cable lines?
(1) The cable specifications should meet the regulations, the arrangement should be neat, no damage, and the signs should be complete, correct and clear;
(2) The fixed bending radius of the cable, the related distance and the wiring of the metal sheath of the single-core power cable should meet the requirements;
(3) The cable terminal and the middle head should not leak oil, and the installation should be firm. The oil pressure of the oil-filled cable and the meter setting should meet the requirements;
(4) Good grounding;
(5) The color of the cable terminal is correct, and the metal parts such as the bracket are completely painted;
(6) There should be no debris in the cable trench, tunnel, and bridge, and the cover should be complete.

Welcome your inquiry