x
2/0 Dungeness Aluminum Conductor Triplex Overhead Service Drop Cable
2/0 Dungeness Aluminum Conductor Triplex Overhead Service Drop Cable

2/0 Dungeness Aluminum Conductor Triplex Overhead Service Drop Cable

The 2/0 Dungeness Aluminum Conductor Triplex Overhead Service Drop Cable is engineered to provide safe and efficient overhead power distribution. Featuring two insulated aluminum conductors and a bare aluminum neutral messenger, this cable delivers strong mechanical support and stable electrical transmission. The 2/0 Dungeness Aluminum Conductor Triplex Overhead Service Drop Cable is manufactured using premium aluminum materials and weather-resistant insulation to ensure long service life in outdoor environments. Its optimized design allows for easy installation while maintaining compliance with utility and industry standards. The cable performs reliably under mechanical stress, temperature changes, and prolonged UV exposure. Strict quality control and systematic testing procedures are applied throughout production to ensure consistent performance and dependable field operation.
Construction
Technical Specifications
Quality Control
Application

Construction

2/0 Dungeness Aluminum Conductor Triplex Overhead Service Drop Cable Constrution
2/0 Dungeness Aluminum Conductor Triplex Overhead Service Drop Cable

Standard

• ASTM B-230 Aluminum Wire, 1350-H19 for Electrical Purposes.
• ASTM B-231 Aluminum Conductors, Concentric-Lay-Stranded.
• ASTM B-232 Aluminum Conductors, Concentric-Lay-Stranded, Coated Steel Reinforced (ACSR).
• ASTM B-399 Concentric-Lay-Stranded 6201-T81 Aluminum Alloy Conductors.
• ICEA S-76-474-Neutral-supported Power Cable Assemblies With Weather-Resistant Extruded Insulation Rated 600 Volts.

Phase Conductor

Strand or Compressed 1350-H19 Series Aluminum Conductor.

Neutral (Messenger) Conductor

Bare AAAC messenger. Optional constructions include a messenger of AAC or AAC

Insulation

Black Cross Linked Polyethylene (XLP) Insulation.

Key Features

1. Voltage Rating: 600 Volts phase-to-phase
2. Temperature Rating: 75°C (PE), 90°C (XLPE)
3. Neutral Messenger: Bare ACSR – High mechanical strength
4. Insulation: Black cross-linked polyethylene (XLPE) for durability
5. Weather & UV Resistant – Ideal for overhead use in all climates
6. Optional Messenger Materials: AAC or 6201 available upon request

Application

2/0 Dungeness Triplex aluminum has three conductors, with one of them being for the neutral path, and two electrodes. The aluminum triplex cable is an electrical cable meant for power distribution from the utility lines to the consumer’s premises through the weather head. It has an operational voltage rating of 600 V and a maximum temperature rating of 75°C. A bare messenger wire of this electrical cable is bonded closely to the two insulated aluminum conductors, which are individually insulated with black cross-linked polyethylene for protection.

Also Known As

2/0 dungeness triplex aluminum wire, 2/0 dungeness triplex overhead wire, 2/0 dungeness aluminum triplex, 2/0 dungeness triplex conductor, 2/0 dungeness overhead aluminum wire, 2/0 dungeness aluminium overhead cables, 2/0 dungeness overhead service drop conductors.

Technical Specifications

2/0 Dungeness Aluminum Conductor Triplex Overhead Service Drop Cable
2/0 Dungeness Aluminum Conductor Triplex Overhead Service Drop Cable
Rated voltage V 600
Test voltage Veff kV/Hz 4/50
Laying temperature °C min. -5
Operating temperature °C -30 ~ +90
Conductor temperature °C max. +90
Short-circuit temperature °C/s max. +250 /5
Bending radius (min.) mm 20 × Ø of cable

Quality Control

2/0 Dungeness Aluminum Conductor Triplex Overhead Service Drop Cable
2/0 Dungeness Aluminum Conductor Triplex Overhead Service Drop Cable Material Test

Raw Material Test

The Raw Material Test for the 2/0 Dungeness Aluminum Conductor Triplex Overhead Service Drop Cable begins with supplier verification and batch identification. Step one evaluates aluminum rods for chemical composition, conductivity, tensile strength, and elongation. Step two tests insulation compounds for thermal stability, tensile performance, and resistance to aging. Step three includes moisture analysis and contamination checks to ensure material purity. All approved raw materials are recorded and fully traceable throughout production. This disciplined Raw Material Test process ensures that the 2/0 Dungeness Aluminum Conductor Triplex Overhead Service Drop Cable is manufactured using only qualified inputs.

2/0 Dungeness Aluminum Conductor Triplex Overhead Service Drop Cable Process inspection

Process inspection

Process Inspection for the 2/0 Dungeness Aluminum Conductor Triplex Overhead Service Drop Cable focuses on precision control at each manufacturing stage. Step one checks wire drawing tolerances and surface smoothness. Step two inspects conductor stranding geometry and flexibility. Step three controls insulation extrusion parameters such as temperature, thickness, and concentricity, supported by continuous spark testing. Step four verifies cabling tension, lay length, and conductor alignment. Regular sampling ensures electrical resistance and mechanical properties remain within specification.

2/0 Dungeness Aluminum Conductor Triplex Overhead Service Drop Cable Finished Product

Finished Product

Finished Product Testing of the 2/0 Dungeness Aluminum Conductor Triplex Overhead Service Drop Cable includes comprehensive final evaluations. Step one conducts DC resistance and continuity testing. Step two applies tensile load testing to confirm mechanical integrity. Step three performs insulation voltage withstand testing. Step four carries out environmental aging simulations. Visual inspection and dimensional verification complete the process, ensuring only compliant products are shipped.

Application

The 2/0 Dungeness Aluminum Conductor Triplex Overhead Service Drop Cable is suitable for overhead electrical service connections in residential areas, commercial facilities, and utility distribution systems.

Technical Advantages

● 30+ years of manufacturing experience
● ISO and UL certified production
● Customized cable and transformer solutions

Product Packaging

Wires and Cables packaging (1)
Wires and Cables packaging (1)
Wires and Cables packaging (2)
Wires and Cables packaging (2)
Wires and Cables packaging (3)
Wires and Cables packaging (3)
Wires and Cables packaging (4)
Wires and Cables packaging (4)
Wires and Cables packaging (5)
Wires and Cables packaging (5)
Wires and Cables packaging (6)
Wires and Cables packaging (6)
Wires and Cables packaging (7)
Wires and Cables packaging (7)
Wires and Cables packaging (8)
Wires and Cables packaging (8)

Related Products

FAQ From Customers

What are the advantages of power cables and overhead lines?
(1) Reliable operation, because it is installed in a hidden place such as underground, it is less damaged by external forces, has less chance of failure, and the power supply is safe, and it will not cause harm to people;
(2) The maintenance workload is small and frequent inspections are not required;
(3) No need to erect towers;
(4) Help improve power factor.
Which aspects should be considered when choosing the cross section of a power cable?
(1) The long-term allowable working current of the cable;
(2) Thermal stability once short circuited;
(3) The voltage drop on the line cannot exceed the allowable working range.
What are the measures for cable fire prevention?
(1) Use flame-retardant cables;
(2) Use fireproof cable tray;
(3) Use fireproof paint;
(4) Fire partition walls and fire baffles are installed at cable tunnels, mezzanine exits, etc.;
(5) Overhead cables should avoid oil pipelines and explosion-proof doors, otherwise local pipes or heat insulation and fire prevention measures should be taken.
What should be paid attention to during the transportation and handling of cables?
(1) During transportation, loading and unloading, cables and cable reels should not be damaged. It is strictly forbidden to push the cable reels directly from the vehicle. Generally, cables should not be transported and stored flat.
(2) Before transporting or rolling the cable reel, ensure that the cable reel is firm, the cable is wound tightly, the oil pipe between the oil-filled cable and the pressure oil tank should be fixed without damage, the pressure oil tank should be firm, and the pressure indication should meet the requirements.
What inspections should be carried out for the acceptance of cable lines?
(1) The cable specifications should meet the regulations, the arrangement should be neat, no damage, and the signs should be complete, correct and clear;
(2) The fixed bending radius of the cable, the related distance and the wiring of the metal sheath of the single-core power cable should meet the requirements;
(3) The cable terminal and the middle head should not leak oil, and the installation should be firm. The oil pressure of the oil-filled cable and the meter setting should meet the requirements;
(4) Good grounding;
(5) The color of the cable terminal is correct, and the metal parts such as the bracket are completely painted;
(6) There should be no debris in the cable trench, tunnel, and bridge, and the cover should be complete.

Welcome your inquiry