700kVA Oil Immersed Transformer
- Primary Voltage Ratings 34.5-19.92/13.8-7.957, 24.94, 26.25, 33 or others
- Secondary Voltage Ratings 480/277V, 400/230V, 380/220V or customized
- H.V. Tap Range ± 2×2.5% HV taps or others
- Type Oil immersed distribution transformer
- BIL 30/95kV
- Standards IEEE, ANSI, NEMA, IEC, CE
- Application industrial plants, residential communities
- Power Rating 700kVA
- Certificate UL, CESI, IEEE
- Cooling Method ONAN, ONAN/ONAF, KNAN, KNAN/KNAF
- Oil Mineral Oil or FR3
- Opeartion Step Down & Step Up
Technical Specifications
| Rated Power | 700kVA | |
| Rating Primary Voltage | 2.4 - 34.5kV | |
| Secondary Voltage | 480/277V 400/230V 380/220V Customized |
|
| Frequency | 50/60Hz | |
| Vector Group | Dyn11, Yyn0, Dyn5 | |
| Winding Material | Aluminum/Copper | |
| Efficiency | As IEEE, Doe 2016, CAS Std or Customized | |
| Impedance Voltage | Nominal 2% or Customized 1.1 - 5.75% | |
| Altitude | ≤1,000m or Customized | |
| Color | ANSI 70 Light gray/Munsell 7GY3.29/1.5 or customized, etc | |
| Tank material | Mild Steel, 304 Stainless Steel | |
| Insulating Oil Weight | 900 kg | |
| Total Weight | 3100 kg | |
| Outline Dimensions(L×W×H)in. | 1950 × 1060 × 1900(mm) | |
| HV Bushing |
| LV Bushing |
| Tap changer |
| Oil level gauge |
| Oil temperature indicator |
| Pressure relief device |
| Pressure vacuum gauge |
| Lifting hook for complete transformer |
| Name plate |
| Radiators |
| Oil upper filtering valve |
| Oil drain valve with 3/8" sampler |
Customization Optional
Packing and Shipping
Component-level protection includes radiators individually crated with vibration-isolating padding, high-voltage bushings in reinforced, shock-absorbent cases, and auxiliary controls sealed with humidity absorbers. The transformer body is anchored to heavy-duty ISPM-15 compliant wooden crates or steel platforms incorporating precise blocking, side restraints, and impact-dampening systems engineered for 4-5g transport accelerations. Full packaging layers feature durable weather barriers, volatile corrosion inhibitors, environmental indicators for humidity/temperature, and electronic shock/tilt monitors to record handling conditions.
Ocean transportation, prevalent for global exports, utilizes flat-rack or open-top containers secured per IMO lashing guidelines, with salt-resistant coverings and protective enclosures; overland/rail movements employ specialized low-loader trailers with weight-balanced supports and accessible lift points. Export documentation encompasses commercial invoices, detailed packing lists, certificates of origin and conformity, routine test protocols, engineering drawings (dimensional/lifting), oil material safety data sheets, installation/handling instructions, and HS code classifications (8504.21 for distribution transformers ≤650kVA, or adjusted per rating).
We deliver integrated logistics services from origin to destination, including FOB/CIF/door-to-door arrangements, customs brokerage, cargo insurance, and premium add-ons such as independent inspections, professional rigging at arrival, on-site oil reclamation/degassing, erection supervision, and commissioning support. This end-to-end approach eliminates transit vulnerabilities, upholds factory-fresh performance, satisfies international compliance, and guarantees efficient, damage-free arrival for clients in distribution, commercial, and industrial sectors worldwide.
Manufacturer Test
Progress Test
Progress testing for the 700kVA oil immersed transformer initiates with grain-oriented silicon steel sheet evaluation for uniform thickness insulation coating magnetic permeability and precise edge preparation through Epstein frame analysis to achieve minimal core losses then core stacking progress verifies optimized step-lap miter joints uniform clamping torque electromagnetic symmetry and effective vibration damping. Winding fabrication progress monitors conductor purity enamel insulation layering automated tension consistency turn counting accuracy and inter-layer dielectric withstand verification after winding completion. Core-coil assembly progress confirms critical radial axial clearances pressboard spacer placement end-turn insulation integrity and robust compression structures resistant to short-circuit forces. Tank manufacturing progress inspects multi-pass weld seam quality hydrostatic pressure resistance surface grit-blasting epoxy primer topcoat DFT compliance and long-term corrosion protection pre-assembly progress checks bushing radiator valve precise alignment accessory mounting and preliminary vacuum pressure cycle tests to uncover early defects ensuring seamless advancement to comprehensive qualification.
Design Tests
All transformers will be tested after finishing the production, test items as follows:
♦ Insulation Power Factor
♦ Ratio, Polarity, and Phase Relation
♦ Winding Resistance
♦ Impulse Tests
♦ On load Loss Test
♦ No Load Loss Test
♦ Leak Test
♦ DC Insulation Resistance Test
♦ Transformer Turns Ratio/TTR (All Tap Voltages)
♦ Impedance Voltage & Load Loss (Rated Voltage)
♦ Polarity, 1-Ph / Phase Relation, 3-Ph (Rated Voltage)
♦ Excitation & No-Load Loss (Rated Voltage)
♦ Insulation Resistance (Rated Voltage)
♦ Temperature Rise
♦ Dielectric Withstand (Hipot)
Transformer Factory Acceptance Test
Load loss short-circuit impedance efficiency tests for the 700kVA oil immersed transformer short secondary apply reduced primary voltage compute copper losses impedance percentage (~4.5-6%) total losses at 75°C for regulation overload predictions. Oil routine testing verifies dielectric strength (>55kV/2.5mm) water content (<30ppm) acidity initial DGA profile absent fault indicators. Temperature rise indicators confirm gauge accuracy alarm thresholds. Functional verification includes pressure relief device activation gas relay tripping tap changer full-range operation and acoustic power level (<58dB). Mechanical integrity checks encompass tank overpressure endurance leak-free seals bushing coordination wiring continuity. Comprehensive FAT documentation with traceable calibration certificates optional client third-party witnessing certifies IEC 60076 GB/T6451 full compliance routine type test fulfillment prior to release authorization.
Routine Test - Leak Test
Voltage source (usually 500V, 1 KV or 2.5 KV, customized according to test requirements)
Temperature and humidity meter
Ground electrode
Properly connect the test equipment (such as a leak detector) to the pipe, container or sealing structure of the device under test.
Apply Test Voltage:
Apply the appropriate test pressure (e.g. 10 bar, 15 bar, etc.) depending on the equipment's operating pressure or test standard.
Applied test pressure
Leakage (can be monitored by flow meter or other equipment)
Time record (to ensure that the test time meets the standard requirements)
Initial pressure and final pressure (if any changes)
Minor leakage (good): Very small leakage is allowed, and it is necessary to judge whether it is qualified according to industry standards.
Application
Technical Advantages
Product Packaging
Related Products
FAQ From Customers
-
What is a Transformer?A transformer is an electrical device used to change the voltage of alternating current (AC). It works on the principle of electromagnetic induction, converting high-voltage current into low-voltage current or low-voltage current into high-voltage current. Transformers are widely used in power transmission, distribution systems, and various electronic devices.
-
What are the main uses of a transformer?The main use of a transformer is voltage conversion. Transformers are used in power transmission systems to help transfer electricity from power plants to consumers. In addition, transformers are also used in electronic devices such as chargers, televisions, power adapters, etc., to adjust the voltage to meet the requirements of different devices.
-
Do you have UL listed?Yes, our transformer has UL listed. We have exported to America many pad mounted transformer,substation transformer and HV.