x
FLINT AAAC Conductor Cable
FLINT AAAC Conductor Cable

FLINT AAAC Conductor Cable

FLINT AAAC (All Aluminum Alloy Conductor) cables are manufactured in accordance with ASTM B399 and IEC 61089 standards, offering excellent strength, conductivity, and corrosion resistance. They are ideal for overhead transmission and distribution lines, especially in coastal, agricultural, and high-corrosion environments requiring long-span performance.
Voltage Rating Up to 33kV (typical)
Temperature Rating Operating: -10°C to +90°C
Short-circuit (5s): up to 250°C
Construction
Technical Specifications
Quality Control
Application

Construction

FLINT AAAC Conductor Cable Construction
FLINT AAAC Conductor Cable Construction

Conductor

Stranded 1350-H19 aluminum alloy (Class AA or A)

Manufacturer Standard

ASTM B399, IEC 61089, BS 3242, and additional compliance with IEC 62004 for enhanced corrosion resistance

Benefits

Flint AAAC cables offer excellent tensile strength and lightweight properties, making them suitable for long-span overhead installations. Their superior corrosion resistance ensures reliable performance in harsh environments, including coastal and industrial areas, while maintaining high conductivity for efficient power transmission.

Application

FLINT AAAC cables are ideal for overhead power transmission and distribution in urban, rural, and coastal areas, particularly in environments requiring lightweight conductors with high mechanical strength, excellent conductivity, and superior corrosion resistance.

Technical Specifications

FLINT AAAC Conductor Cable
FLINT AAAC Conductor Cable
Construction characteristics
Conductor material aluminum alloy
Type of conductor Circular, stranded
Type of cable Flint
Conductor flexibility Class AA
Conductor shape Circular non compacted
Dimensional characteristics
Conductor cross-section 740.8 kcmil
Conductor cross-section 374.52 mm²
Wire diameter 3.59 mm
Conductor diameter 25.13 mm
Approximate weight 1035 kg/km
Average geometric radius 0.00966 m
Diameter of aluminium alloy 6201 wires 3.59 mm
Nominal diameter of wires 3.59 mm
Nominal outer diameter 25.13 mm
Number of aluminium alloy 6201 wires 37
Number of cores 1
Electrical characteristics
Max. DC resistance of the conductor at 20°C 0.0894 Ohm/km
Max. electric resistance AC 60Hz 75°C 0.108 Ohm/km
Inductive reactance 0.3499 Ohm/km
Capacitive reactance 0.2089 MOhm.km
Ampacity 790.0 A
Mechanical characteristics
Hardness type T81
Rated breaking load 11012.8 kgf
Usage characteristics
Length 2330 m
Reel net weight 2400 kg

Quality Control

FLINT AAAC Conductor Cable
FLINT AAAC Conductor Cable Raw Material Test

Raw Material Test

NPC has always chosen raw material suppliers who have a good reputation, possess stable supply capabilities and have passed international quality system certifications (such as ISO 9001). And establish a long-term cooperative relationship with it, forming a stable and reliable raw material supply chain.
We will ensure that all raw materials are subject to strict inspection procedures upon entry to the factory, and can only be stored in the warehouse after they have been confirmed to meet the standards.

FLINT AAAC Conductor Cable Process inspection

Process inspection

NPC has strict quality control procedures for each process in the cable production process.
Process documents: Develop detailed process flow and operation instructions to clarify the operating specifications and quality standards of each process.
Equipment calibration: Regularly calibrate key equipment such as wire drawing machines, stranding machines, extruders, and diameter gauges to ensure that the accuracy meets the requirements.
First piece confirmation: Before each batch of production, the first piece is trial-produced to confirm that the process parameters, product dimensions, electrical performance, etc. meet the standards before mass production can be carried out.

FLINT AAAC Conductor Cable Finished Product

Finished Product

Inspectors conduct ex-factory inspections on cables according to relevant standards and corresponding product inspection specifications to ensure that each ex-factory product complies with the process regulations.

Application

FLINT AAAC cables are ideal for overhead power transmission and distribution in urban, rural, and coastal areas, particularly in environments requiring lightweight conductors with high mechanical strength, excellent conductivity, and superior corrosion resistance.

Technical Advantages

● 30+ years of manufacturing experience
● ISO and UL certified production
● Customized cable and transformer solutions

Product Packaging

Wires and Cables packaging (1)
Wires and Cables packaging (1)
Wires and Cables packaging (2)
Wires and Cables packaging (2)
Wires and Cables packaging (3)
Wires and Cables packaging (3)
Wires and Cables packaging (4)
Wires and Cables packaging (4)
Wires and Cables packaging (5)
Wires and Cables packaging (5)
Wires and Cables packaging (6)
Wires and Cables packaging (6)
Wires and Cables packaging (7)
Wires and Cables packaging (7)
Wires and Cables packaging (8)
Wires and Cables packaging (8)

Related Products

FAQ From Customers

What are the advantages of power cables and overhead lines?
(1) Reliable operation, because it is installed in a hidden place such as underground, it is less damaged by external forces, has less chance of failure, and the power supply is safe, and it will not cause harm to people;
(2) The maintenance workload is small and frequent inspections are not required;
(3) No need to erect towers;
(4) Help improve power factor.
Which aspects should be considered when choosing the cross section of a power cable?
(1) The long-term allowable working current of the cable;
(2) Thermal stability once short circuited;
(3) The voltage drop on the line cannot exceed the allowable working range.
What are the measures for cable fire prevention?
(1) Use flame-retardant cables;
(2) Use fireproof cable tray;
(3) Use fireproof paint;
(4) Fire partition walls and fire baffles are installed at cable tunnels, mezzanine exits, etc.;
(5) Overhead cables should avoid oil pipelines and explosion-proof doors, otherwise local pipes or heat insulation and fire prevention measures should be taken.
What should be paid attention to during the transportation and handling of cables?
(1) During transportation, loading and unloading, cables and cable reels should not be damaged. It is strictly forbidden to push the cable reels directly from the vehicle. Generally, cables should not be transported and stored flat.
(2) Before transporting or rolling the cable reel, ensure that the cable reel is firm, the cable is wound tightly, the oil pipe between the oil-filled cable and the pressure oil tank should be fixed without damage, the pressure oil tank should be firm, and the pressure indication should meet the requirements.
What inspections should be carried out for the acceptance of cable lines?
(1) The cable specifications should meet the regulations, the arrangement should be neat, no damage, and the signs should be complete, correct and clear;
(2) The fixed bending radius of the cable, the related distance and the wiring of the metal sheath of the single-core power cable should meet the requirements;
(3) The cable terminal and the middle head should not leak oil, and the installation should be firm. The oil pressure of the oil-filled cable and the meter setting should meet the requirements;
(4) Good grounding;
(5) The color of the cable terminal is correct, and the metal parts such as the bracket are completely painted;
(6) There should be no debris in the cable trench, tunnel, and bridge, and the cover should be complete.

Welcome your inquiry

Honesty, Integrity, Frugality, Activeness and Passion