Wires and Cables
Bare Conductor
2 AWG SPARROW ACSR Conductor Cable
The 2 AWG SPARROW ACSR (Aluminum Conductor Steel Reinforced) cable, compliant with ASTM B232, ABNT NBR 7270/88, and IEC 61089 standards, is engineered for dependable performance in overhead transmission and distribution systems. Featuring a stranded 1350-H19 aluminum conductor for excellent electrical conductivity and a single galvanized steel core for enhanced mechanical strength, this cable is ideal for medium to long-span installations in suburban, agricultural, and utility networks. With a voltage rating of up to 25 kV, an operating temperature range of -10°C to +75°C, and a short-circuit tolerance of up to 150°C (5s), the SPARROW ACSR ensures reliable conductivity, corrosion resistance, and durability under wind and ice loading. Its lightweight, bare aluminum design with a corrosion-resistant steel core simplifies installation and ensures a long service life in diverse outdoor environments. Ampacity is calculated under standard conditions (conductor temperature: 75°C; ambient temperature: 25°C; wind speed: 1 m/s; full sun exposure).
4 AWG SWAN ACSR Conductor Cable
4 AWG SWAN ACSR cable is an aluminum conductor steel-reinforced cable manufactured according to ABNT NBR 7270/88 standards, combining high conductivity with enhanced tensile strength. It is commonly used in overhead power transmission and distribution lines, especially where increased mechanical support is needed for longer spans or adverse weather conditions.
4 AWG SWANATE ACSR Conductor Cable
4 AWG SWANATE ACSR cable is a steel-reinforced aluminum conductor manufactured in compliance with ABNT NBR 7270/88 standards, combining durability with efficient electrical performance. It is well-suited for overhead power distribution systems in rural or utility areas where stable conductivity and mechanical support are needed for short to medium spans.
AAAC Dog Conductor Cable
AAAC DOG conductor is an All Aluminum Alloy Conductor manufactured according to ASTM B399 or IEC 61089 standards, offering high strength, good conductivity, and excellent corrosion resistance. It is widely used in overhead transmission and distribution lines, especially in coastal or industrial areas where durability and lightweight construction are critical.
AAAC Moose Conductor Cable
AAAC MOOSE conductor is manufactured in compliance with ASTM B399 or IEC 61089 standards, using high-strength aluminum alloy 6201-T81 for enhanced conductivity and corrosion resistance. It is primarily used in high-voltage overhead transmission lines, especially in areas requiring long spans, minimal sag, and reliable performance under harsh environmental conditions.
AAAC Panther Conductor Cable
AAAC PANTHER Conductor is a premium-grade All Aluminum Alloy Conductor engineered for reliable performance in overhead distribution and sub-transmission lines. Compliant with ASTM B399, IEC 61089, and BS EN 50182 standards, this conductor is manufactured using high-strength 6201-T81 aluminum alloy, offering excellent conductivity, enhanced tensile strength, and superior corrosion resistance. Optimized for medium to long spans, AAAC PANTHER is ideal for use in urban, semi-urban, and industrial zones, where environmental conditions demand durable, lightweight, and thermally efficient solutions with low line losses and minimal maintenance requirements.
AAAC Rabbit Conductor Cable
AAAC RABBIT conductor is a compact, high-performance All Aluminum Alloy Conductor manufactured using 6201-T81 aluminum alloy, in compliance with ASTM B399, IEC 61089, and BS EN 50182 standards. Known for its balanced mechanical strength, excellent conductivity, and superior corrosion resistance, this conductor is ideal for short to medium-span overhead distribution lines, especially in rural, township, and semi-urban areas. Its lightweight structure and smooth bare finish make it easy to handle and install, while ensuring stable performance under diverse environmental conditions. AAAC RABBIT is a cost-effective solution for utilities seeking long-term reliability with low maintenance requirements.
ALLIANCE AAAC Conductor Cable
ALLIANCE AAAC (All Aluminum Alloy Conductor) cables are manufactured in strict compliance with international standards such as ASTM B399, IEC 61089, and BS EN 50182, making them a high-performance and reliable overhead power transmission and distribution solution. In terms of performance, this cable demonstrates excellent comprehensive advantages. It uses 6201-T81 aluminum alloy conductors (Class AA or A), which have high tensile strength and can easily meet the mechanical requirements of long-span overhead scenarios. At the same time, it has excellent conductivity to ensure efficient and stable power transmission. What's more, its outstanding corrosion resistance and smooth, corrosion-resistant surface treatment enable it to operate stably for a long time in harsh conditions such as coastal areas with high humidity and high salt spray, as well as industrial polluted areas, greatly reducing maintenance costs.
AMES AAAC Conductor Cable
AMES AAAC (All Aluminum Alloy Twisted) cables comply with ASTM B399 standards and have excellent conductivity and corrosion resistance. Suitable for overhead transmission and distribution lines, especially suitable for medium and high voltage transmission systems in coastal or high-corrosion environments.In-Depth Analysis
Comparative Analysis of Efficiency and Loss
Compared to the industry average, bare conductor cables exhibit lower losses and higher efficiency across the entire load range.
Load Efficiency Comparison(%)
No-load Loss Comparison(W)
High Conductivity Design
High-purity oxygen-free copper or high-quality aluminum conductors are used with smooth surface and low resistance to ensure efficient power transmission and reduce energy loss.
Insulation Protection System
Use flame-retardant, wear-resistant and corrosion-resistant polymer insulation materials to meet the safe operation requirements in different environments.
Weather-Resistant & Durable Technology
The outer sheath is made of UV-resistant, heat-resistant, and oil-resistant materials, making it suitable for high and low temperatures, humidity, and long-term outdoor use.
Safe Flame Retardant System
The multi-layered flame-retardant structure effectively slows the spread of flames and releases low-smoke, halogen-free gases during combustion, reducing secondary hazards.
Easy Installation & Maintenance
The flexible core and flex-resistant outer sheath provide a small bend radius and high installation efficiency. Color coding and length markings reduce installation and maintenance costs.
Intelligent Monitoring
An optional remote monitoring system is available to monitor operating status, temperature, load and other parameters in real time, and supports fault warning and remote diagnosis.
Environmental Adaptability Analysis
Bare conductor cables have been rigorously tested and can operate stably under various harsh environmental conditions.
Temperature Range
-40℃ ~ +55℃
Can work normally in extreme high and low temperature environments
Humidity Adaptation
0 ~ 100% RH
Including condensation environment, no frost requirement
Weather Resistance Grade
UV/IEC 60811-501
The outer sheath has excellent UV resistance and aging resistance
Chemical Corrosion Resistance
Oil / Acid / Alkali
Resistant to oil, acid, alkali and some chemical corrosion environments
Why Choose Us
Bare Conductor Cables Manufacturer
Bare Conductor Cables Advantages
AAC AAAC ACSR ACAR Conductor
Bare Conductor Quality Control
Product Show
Testing and Certification
Bare Cable Test Report
SGS Inspection Report
Certificate of Acceptance
ISO Quality Certificate
ISO Environmental Certificate
ISO Occupational Certificate
UL Laboratory Certificate
UL Product Certificate
Project Cases
Peru Solar PV Project
CompletedNPC Electric Delivers Medium-Voltage Cables for Peru Solar PV Project
Country:Peru
Model:HEPRZ1(AS) 1x630 mm² 19/33kV x 6km
Chile El Project
CompletedReliable 19/33kV MV cables ensuring safe, stable, and efficient power transmission for critical projects.
Country:Chile
Model:19/33kV MV Power Cables x 5km
Dominican Edenorte Project
CompletedProvide outdoor power solutions for urban main road reconstruction projects to adapt to complex environments.
Country:Dominican
Model:NPC AAAC Cable & Triplex Cable x 10km
Technical Advantages
FAQ From Customers
-
What is a bare conductor cable?
A bare conductor cable is an electrical cable made of bare aluminum or bare copper conductors without any insulation. These cables are widely used in overhead power lines, power transmission systems, and aerial conductors. Bare conductor cables offer excellent conductivity and high tensile strength, making them ideal for long-distance energy transfer and outdoor installations. -
Bare Copper Conductors vs Bare Copper Ground Conductors, what’s the difference?
Bare copper conductors are typically used in power transmission, providing high conductivity for energy delivery. Bare copper ground conductors, however, are designed for grounding purposes and ensure safety by providing a path to dissipate fault currents safely into the earth. While both are made of copper, ground conductors are often thicker to handle fault conditions without overheating or breaking. -
What is the difference between AAC and ACSR conductors?
AAC (All Aluminum Conductor) and ACSR (Aluminum Conductor Steel Reinforced) differ primarily in their construction. AAC conductors are made entirely of aluminum, offering lightweight and high conductivity. ACSR conductors, on the other hand, have a steel core that enhances tensile strength, making them ideal for long-distance transmission and high mechanical stress. While AAC is suitable for shorter distances, ACSR is typically used for overhead lines with longer spans and high voltage transmission. -
What is the difference between bare conductor and insulated conductor?
Bare conductor cables are uninsulated and typically used in overhead power lines where external insulation is unnecessary. In contrast, insulated conductor cables have a protective layer of material like PVC or XLPE, offering protection against electrical shock and short circuits. Insulated cables are commonly used for underground installations or where conductors are exposed to moisture, chemicals, or mechanical damage. -
What types of electrical cables are used for power transmission?
Various types of electrical cables are used for power transmission, including bare conductor cables like AAC, ACSR, and AAAC. These cables are ideal for overhead power lines because of their high conductivity and durability. For underground or shielded installations, insulated conductors are often used. NPC Electric manufactures electrical cables for both low voltage and high voltage systems, ensuring reliable and efficient power delivery in diverse applications.