4/0 Zuzara Aluminum Conductor Triplex Overhead Service Drop Cable
4/0 Zuzara Aluminum Conductor Triplex Overhead Service Drop Cable

4/0 Zuzara Aluminum Conductor Triplex Overhead Service Drop Cable

4/0 Zuzara Aluminum Triplex Overhead Service Drop Cable is engineered for efficient and reliable overhead power distribution from utility poles to residential or commercial premises through a weather head. The cable features two phase conductors and a bare ACSR messenger wire bonded closely to provide neutral support. Each aluminum conductor is insulated with UV-resistant black cross-linked polyethylene (XLP) for long-lasting outdoor performance. This triplex cable is designed for 600V applications and is compliant with major ASTM and ICEA standards.
Construction
Technical Specifications
Quality Control
Application

Construction

4/0 Zuzara Aluminum Conductor Triplex Overhead Service Drop Cable Constrution
4/0 Zuzara Aluminum Conductor Triplex Overhead Service Drop Cable

Standard

• ASTM B-230 Aluminum Wire, 1350-H19 for Electrical Purposes.
• ASTM B-231 Aluminum Conductors, Concentric-Lay-Stranded.
• ASTM B-232 Aluminum Conductors, Concentric-Lay-Stranded, Coated Steel Reinforced (ACSR).
• ASTM B-399 Concentric-Lay-Stranded 6201-T81 Aluminum Alloy Conductors.
• ICEA S-76-474-Neutral-supported Power Cable Assemblies With Weather-Resistant Extruded Insulation Rated 600 Volts.

Phase Conductor

Strand or Compressed 1350-H19 Series Aluminum Conductor.

Neutral (Messenger) Conductor

Bare ACSR messenger. Optional constructions include a messenger of AAC or 6201 alloy.

Insulation

Black Cross Linked Polyethylene (XLP) Insulation.

Key Features

1. Designed for overhead service drop installations
2. 600V voltage rating for residential and commercial utility applications
3. Durable ACSR messenger enhances mechanical strength
4. Resistant to UV, abrasion, and weathering
5. Lightweight and corrosion-resistant aluminum conductors
6. Fully compliant with ICEA and ASTM standards

Application

4/0 Zuzara Aluminum Conductor Overhead Service Drop Cable has three conductors, with one of them being for neutral path, and two electrodes. The aluminum triplex cable is an electrical cable meant for power distributions from the utility lines to the consumer’s premises through the weather head. It has an operational voltage rating at 600 V and the maximum temperature rating of 75°C. A bare messenger wire of this electrical cable is bonded closely on the two insulated aluminum conductors, which are individually insulated with black cross-linked polyethylene for protection.

Also Known As

4/0 zuzara triplex aluminum wire, 4/0 zuzara triplex overhead wire, 4/0 zuzara aluminum triplex, 4/0 zuzara triplex conductor, 4/0 zuzara overhead aluminum wire, 4/0 zuzara aluminium overhead cables, 4/0 zuzara overhead service drop conductors.

Technical Specifications

4/0 Zuzara Aluminum Conductor Triplex Overhead Service Drop Cable
4/0 Zuzara Aluminum Conductor Triplex Overhead Service Drop Cable
Rated voltage V 600
Test voltage Veff kV/Hz 4/50
Laying temperature °C min. -5
Operating temperature °C -30 ~ +90
Conductor temperature °C max. +90
Short-circuit temperature °C/s max. +250 /5
Bending radius (min.) mm 20 × Ø of cable

Quality Control

4/0 Zuzara Aluminum Conductor Triplex Overhead Service Drop Cable
4/0 Zuzara Aluminum Conductor Triplex Overhead Service Drop Cable Material Test

Raw Material Test

NPC has always chosen raw material suppliers who have a good reputation, possess stable supply capabilities and have passed international quality system certifications (such as ISO 9001). And establish a long-term cooperative relationship with it, forming a stable and reliable raw material supply chain.
We will ensure that all raw materials are subject to strict inspection procedures upon entry to the factory, and can only be stored in the warehouse after they have been confirmed to meet the standards.

4/0 Zuzara Aluminum Conductor Triplex Overhead Service Drop Cable Process inspection

Process inspection

NPC has strict quality control procedures for each process in the cable production process.
Process documents: Develop detailed process flow and operation instructions to clarify the operating specifications and quality standards of each process.
Equipment calibration: Regularly calibrate key equipment such as wire drawing machines, stranding machines, extruders, and diameter gauges to ensure that the accuracy meets the requirements.
First piece confirmation: Before each batch of production, the first piece is trial-produced to confirm that the process parameters, product dimensions, electrical performance, etc. meet the standards before mass production can be carried out.

4/0 Zuzara Aluminum Conductor Triplex Overhead Service Drop Cable Finished Product

Finished Product

Inspectors conduct ex-factory inspections on cables according to relevant standards and corresponding product inspection specifications to ensure that each ex-factory product complies with the process regulations.

Application

4/0 Zuzara Aluminum Conductor Overhead Service Drop Cable has three conductors, with one of them being for neutral path, and two electrodes. A bare messenger wire of this electrical cable is bonded closely on the two insulated aluminum conductors, which are individually insulated with black cross-linked polyethylene for protection.

Technical Advantages

● 30+ years of manufacturing experience
● ISO and UL certified production
● Customized cable and transformer solutions

Product Packaging

Wires and Cables packaging (1)
Wires and Cables packaging (1)
Wires and Cables packaging (2)
Wires and Cables packaging (2)
Wires and Cables packaging (3)
Wires and Cables packaging (3)
Wires and Cables packaging (4)
Wires and Cables packaging (4)
Wires and Cables packaging (5)
Wires and Cables packaging (5)
Wires and Cables packaging (6)
Wires and Cables packaging (6)
Wires and Cables packaging (7)
Wires and Cables packaging (7)
Wires and Cables packaging (8)
Wires and Cables packaging (8)

Related Products

FAQ From Customers

What are the advantages of power cables and overhead lines?
(1) Reliable operation, because it is installed in a hidden place such as underground, it is less damaged by external forces, has less chance of failure, and the power supply is safe, and it will not cause harm to people;
(2) The maintenance workload is small and frequent inspections are not required;
(3) No need to erect towers;
(4) Help improve power factor.
Which aspects should be considered when choosing the cross section of a power cable?
(1) The long-term allowable working current of the cable;
(2) Thermal stability once short circuited;
(3) The voltage drop on the line cannot exceed the allowable working range.
What are the measures for cable fire prevention?
(1) Use flame-retardant cables;
(2) Use fireproof cable tray;
(3) Use fireproof paint;
(4) Fire partition walls and fire baffles are installed at cable tunnels, mezzanine exits, etc.;
(5) Overhead cables should avoid oil pipelines and explosion-proof doors, otherwise local pipes or heat insulation and fire prevention measures should be taken.
What should be paid attention to during the transportation and handling of cables?
(1) During transportation, loading and unloading, cables and cable reels should not be damaged. It is strictly forbidden to push the cable reels directly from the vehicle. Generally, cables should not be transported and stored flat.
(2) Before transporting or rolling the cable reel, ensure that the cable reel is firm, the cable is wound tightly, the oil pipe between the oil-filled cable and the pressure oil tank should be fixed without damage, the pressure oil tank should be firm, and the pressure indication should meet the requirements.
What inspections should be carried out for the acceptance of cable lines?
(1) The cable specifications should meet the regulations, the arrangement should be neat, no damage, and the signs should be complete, correct and clear;
(2) The fixed bending radius of the cable, the related distance and the wiring of the metal sheath of the single-core power cable should meet the requirements;
(3) The cable terminal and the middle head should not leak oil, and the installation should be firm. The oil pressure of the oil-filled cable and the meter setting should meet the requirements;
(4) Good grounding;
(5) The color of the cable terminal is correct, and the metal parts such as the bracket are completely painted;
(6) There should be no debris in the cable trench, tunnel, and bridge, and the cover should be complete.