2 Conch Aluminum Conductor Triplex Overhead Service Drop Cable
2 Conch Aluminum Conductor Triplex Overhead Service Drop Cable

2 Conch Aluminum Conductor Triplex Overhead Service Drop Cable

The 2-2-2 Conch Aluminum Conductor Triplex Overhead Service Drop Cable is a trusted solution for overhead power distribution from utility poles to residential or commercial weatherheads. Featuring concentric-lay-stranded 1350-H19 aluminum phase conductors (#2 AWG, 7-strand), durable black cross-linked polyethylene (XLPE) insulation, and a bare ACSR neutral messenger (#2 AWG, 6/1), it provides excellent electrical conductivity, superior weather/UV resistance, and mechanical support. Rated for 600 volts phase-to-phase with conductor temperatures up to 90°C (XLPE), it delivers an allowable ampacity of approximately 150 amps. Compliant with ASTM B-230, B-231, B-232, B-399, and ICEA S-76-474 standards, this lightweight, flexible cable ensures easy installation and long-term reliability in harsh outdoor environments, including wind, ice loading, and temperature fluctuations.
Construction
Technical Specifications
Quality Control
Application

Construction

2 Conch Aluminum Conductor Triplex Overhead Service Drop Cable Constrution
2 Conch Aluminum Conductor Triplex Overhead Service Drop Cable

Standard

• ASTM B-230 Aluminum Wire, 1350-H19 for Electrical Purposes.
• ASTM B-231 Aluminum Conductors, Concentric-Lay-Stranded.
• ASTM B-232 Aluminum Conductors, Concentric-Lay-Stranded, Coated Steel Reinforced (ACSR).
• ASTM B-399 Concentric-Lay-Stranded 6201-T81 Aluminum Alloy Conductors.
• ICEA S-76-474-Neutral-supported Power Cable Assemblies With Weather-Resistant Extruded Insulation Rated 600 Volts.

Phase Conductor

Strand or Compressed 1350-H19 Series Aluminum Conductor.

Neutral (Messenger) Conductor

Bare AAAC messenger.

Insulation

Black Cross Linked Polyethylene (XLP) Insulation.

Key Features

1. Voltage rating: 600 volts
2. Temperature rating: 75°C (PE), 90°C (XLP)
3. Conductors: 1350-H19 Aluminum, stranded or compressed
4. Bare AAAC messenger for neutral and support
5. Insulation: Black Cross-Linked Polyethylene (XLPE)
6. Weather Resistance: Excellent UV and moisture protection

Application

2 Conch Aluminum Conductor Overhead Service Drop Cable Wire has three conductors, with one of them being for the neutral path, and two electrodes. Used to supply power, usually from a pole-mounted transformer, to the user's service head, where connection to the service entrance cable is made. To be used at voltages of 600 volts phase-to-phase or less and at conductor temperatures not to exceed 75°C for polyethylene insulated conductors or 90°C for cross-linked polyethylene (XLPE) insulated conductors.

Technical Specifications

2 Conch Aluminum Conductor Triplex Overhead Service Drop Cable
2 Conch Aluminum Conductor Triplex Overhead Service Drop Cable
Rated voltage V 600
Test voltage Veff kV/Hz 4/50
Laying temperature °C min. -5
Operating temperature °C -30 ~ +90
Conductor temperature °C max. +90
Short-circuit temperature °C/s max. +250 /5
Bending radius (min.) mm 20 × Ø of cable

Quality Control

2 Conch Aluminum Conductor Triplex Overhead Service Drop Cable
2 Conch Aluminum Conductor Triplex Overhead Service Drop Cable Material Test

Raw Material Test

Raw materials for 2-2-2 Conch Aluminum Conductor Triplex Overhead Service Drop Cable undergo stringent incoming quality checks. 1. Aluminum rods (1350-H19 grade) are tested via optical emission spectroscopy for ≥99.5% aluminum purity, with impurities (Fe, Si) controlled ≤0.1%; conductivity (>61% IACS), tensile strength (>170 MPa), and elongation verified per ASTM B-233. 2. ACSR neutral messenger steel core wires checked for zinc coating thickness (Class A galvanization) and breaking strength per ASTM B-498 and B-232. 3. XLPE insulation compound evaluated for density, melt flow index, tensile strength (>8 MPa post-aging), elongation (>200%), and carbon black content for UV protection per ASTM D-1248. 4. Visual and dimensional inspections identify surface flaws or size deviations. Supplier certificates of analysis are cross-checked with in-house lab testing.

2 Conch Aluminum Conductor Triplex Overhead Service Drop Cable Process inspection

Process inspection

Throughout the manufacturing of 2-2-2 Conch Aluminum Conductor Triplex Overhead Service Drop Cable, in-line inspections maintain precision. 1. Stranding: Concentric stranding of #2 AWG phase conductors (7 wires) and ACSR neutral monitored for uniform lay length, no birdcaging, and consistent tension. 2. Extrusion: XLPE insulation applied under controlled temperature/speed; online gauges confirm nominal thickness (≈0.045–0.050 inches) and concentricity, with no voids detected. 3. Cabling/twisting: Two insulated phases twisted around bare neutral at specified lay for balanced triplex structure without insulation damage. 4. High-voltage spark testing scans continuously for pinholes or faults. 5. Periodic sampling checks conductor resistance, insulation integrity, and visual surface quality. Deviations prompt immediate line adjustments, hold tags, and corrective actions per ISO protocols to ensure consistent quality.

2 Conch Aluminum Conductor Triplex Overhead Service Drop Cable Finished Product

Finished Product

Final verification on completed 2-2-2 Conch Aluminum Conductor Triplex Overhead Service Drop Cable includes: 1. Electrical: DC resistance per ASTM B-231 (max for #2 AWG); insulation resistance >1000 MΩ-km at 500V DC. 2. Voltage withstand: AC high-potential test at 3kV for 5 minutes, no breakdown. 3. Physical: Insulation thickness/eccentricity measured microscopically; tensile strength and elongation of conductors/insulation meet ASTM requirements. 4. Ampacity confirmed (~150A at 90°C XLPE). 5. Visual/dimensional inspection verifies print accuracy (code word "Conch", size, voltage, standards), no abrasions, and proper flexibility/coiling. 6. Sample mechanical tests (bend, impact) confirm durability. Results documented in full test reports; only compliant reels certified, labeled, and released for delivery.

Application

Primarily for overhead service drops from pole-mounted transformers to building service entrances in residential and light commercial areas. Ideal for single-phase 600V power supply in urban/rural settings, secondary pole-to-pole distribution, and durable connections in diverse weather conditions.

Technical Advantages

● 30+ years of manufacturing experience
● ISO and UL certified production
● Customized cable and transformer solutions

Product Packaging

Wires and Cables packaging (1)
Wires and Cables packaging (1)
Wires and Cables packaging (2)
Wires and Cables packaging (2)
Wires and Cables packaging (3)
Wires and Cables packaging (3)
Wires and Cables packaging (4)
Wires and Cables packaging (4)
Wires and Cables packaging (5)
Wires and Cables packaging (5)
Wires and Cables packaging (6)
Wires and Cables packaging (6)
Wires and Cables packaging (7)
Wires and Cables packaging (7)
Wires and Cables packaging (8)
Wires and Cables packaging (8)

Related Products

FAQ From Customers

What are the advantages of power cables and overhead lines?
(1) Reliable operation, because it is installed in a hidden place such as underground, it is less damaged by external forces, has less chance of failure, and the power supply is safe, and it will not cause harm to people;
(2) The maintenance workload is small and frequent inspections are not required;
(3) No need to erect towers;
(4) Help improve power factor.
Which aspects should be considered when choosing the cross section of a power cable?
(1) The long-term allowable working current of the cable;
(2) Thermal stability once short circuited;
(3) The voltage drop on the line cannot exceed the allowable working range.
What are the measures for cable fire prevention?
(1) Use flame-retardant cables;
(2) Use fireproof cable tray;
(3) Use fireproof paint;
(4) Fire partition walls and fire baffles are installed at cable tunnels, mezzanine exits, etc.;
(5) Overhead cables should avoid oil pipelines and explosion-proof doors, otherwise local pipes or heat insulation and fire prevention measures should be taken.
What should be paid attention to during the transportation and handling of cables?
(1) During transportation, loading and unloading, cables and cable reels should not be damaged. It is strictly forbidden to push the cable reels directly from the vehicle. Generally, cables should not be transported and stored flat.
(2) Before transporting or rolling the cable reel, ensure that the cable reel is firm, the cable is wound tightly, the oil pipe between the oil-filled cable and the pressure oil tank should be fixed without damage, the pressure oil tank should be firm, and the pressure indication should meet the requirements.
What inspections should be carried out for the acceptance of cable lines?
(1) The cable specifications should meet the regulations, the arrangement should be neat, no damage, and the signs should be complete, correct and clear;
(2) The fixed bending radius of the cable, the related distance and the wiring of the metal sheath of the single-core power cable should meet the requirements;
(3) The cable terminal and the middle head should not leak oil, and the installation should be firm. The oil pressure of the oil-filled cable and the meter setting should meet the requirements;
(4) Good grounding;
(5) The color of the cable terminal is correct, and the metal parts such as the bracket are completely painted;
(6) There should be no debris in the cable trench, tunnel, and bridge, and the cover should be complete.